Sunlight incident on the Earth’s atmosphere is essential for life, and it is the driving force of a host of photo-chemical and environmental processes, such as the radiative heating of the atmosphere. We report the description and application of a physical methodology relative to how an ensemble of very low-cost sensors (with a total cost of <$20, less than 0.5% of the cost of the reference sensor) can be used to provide wavelength resolved irradiance spectra with a resolution of 1 nm between 360–780 nm by calibrating against a reference sensor using machine learning. These low-cost sensor ensembles are calibrated using machine learning and can effectively reproduce the observations made by an NIST calibrated reference instrument (Konica Minolta CL-500A with a cost of around USD 6000). The correlation coefficient between the reference sensor and the calibrated low-cost sensor ensemble has been optimized to have 0.99. Both the circuits used and the code have been made publicly available. By accurately calibrating the low-cost sensors, we are able to distribute a large number of low-cost sensors in a neighborhood scale area. It provides unprecedented spatial and temporal insights into the micro-scale variability of the wavelength resolved irradiance, which is relevant for air quality, environmental and agronomy applications.
The human body is an incredible and complex sensing system. Environmental factors trigger a wide range of automatic neurophysiological responses. Biometric sensors can capture these responses in real time, providing clues about the underlying biophysical mechanisms. In this prototype study, we demonstrate an experimental paradigm to holistically capture and evaluate the interactions between an environmental context and physiological markers of an individual operating that environment. A cyclist equipped with a biometric sensing suite is followed by an environmental survey vehicle during outdoor bike rides. The interactions between environment and physiology are then evaluated though the development of empirical machine learning models, which estimate particulate matter concentrations from biometric variables alone. Here, we show biometric variables can be used to accurately estimate particulate matter concentrations at ultra-fine spatial scales with high fidelity (r = 0.91) and that smaller particles are better estimated than larger ones. Inferring environmental conditions solely from biometric measurements allows us to disentangle key interactions between the environment and the body. This work sets the stage for future investigations of these interactions for a larger number of factors, e.g., black carbon, CO2, NO/NO2/NOx, and ozone. By tapping into our body’s ‘built-in’ sensing abilities, we can gain insights into how our environment influences our physical health and cognitive performance.
Accurate characterization of surface solar irradiance at fine spatial, temporal, and spectral resolution is central to applications such as solar energy and environmental monitoring. On the one hand, modeling radiative transfer to achieve such accuracy requires detailed characterization of a wide range of factors, including the vertical profiles of gaseous and particulate absorbers and scatterers, wavelength-resolved surface reflectivity, and the three-dimensional morphology of clouds. On the other hand, satellite-based remote sensing products typically provide top-of-the-atmosphere irradiance at coarse spatial resolutions, where individual pixels can span several kilometers, failing to capture fine-scale intra-pixel variability. In this study, we introduce a machine learning framework that integrates large-scale remote sensing satellite data with hyperlocal, second-by-second ground-based measurements from an ensemble of low-cost spectral sensors to estimate the wavelength-resolved surface solar irradiance spectra at the hyperlocal level. The satellite data are obtained from the Harmonized Sentinel-2 MSI (MultiSpectral Instrument), Level-2A Surface Reflectance (SR) product, which offers high-resolution surface reflectance data. By leveraging machine learning, we model the relationship between satellite-derived surface reflectance and ground-based spectral measurements to predict high-resolution, wavelength-resolved irradiance, using target data obtained from an NIST-calibrated reference instrument. By utilizing a low-cost sensor ensemble that is easily deployable at scale, combined with downscaled satellite data, this approach enables accurate modeling of intra-pixel variability in surface-level solar irradiance with high temporal resolution. It also enhances the utility of the Harmonized Sentinel-2 MSI data for operational remote sensing. Our results demonstrate that the model is able to estimate surface solar irradiance with an R2 ≈ 0.99 across all 421 spectral bins from 360 nm to 780 nm at 1 nm resolution, offering strong potential for applications in solar energy forecasting, urban climate research, and environmental monitoring.