Yuta Sasatake

Dr. Yuta Sasatake


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2021 in Signals
Verified
Journal Article
Open access
PDF file
JMJoseph Muguro
Joseph Muguro
Pringgo Widyo LaksonoPringgo Widyo Laksono
Pringgo Widyo Laksono
WRWahyu Rahmaniar
Wahyu Rahmaniar
WNwaweru njeri
waweru njeri
YSYuta Sasatake
Yuta Sasatake
Wahyu CaesarendraWahyu Caesarendra
Wahyu Caesarendra
In recent years, surface Electromyography (sEMG) signals have been effectively applied in various fields such as control interfaces, prosthetics, and rehabilitation. We propose a neck rotation estimation from EMG and apply the signal estimate as a game control interface that can be used by people with disabilities or patients with functional impairment of the upper limb. This paper utilizes an equation estimation and a machine learning model to translate the signals into corresponding neck rotations. For testing, we designed two custom-made game scenes, a dynamic 1D object interception and a 2D maze scenery, in Unity 3D to be controlled by sEMG signal in real-time. Twenty-two (22) test subjects (mean age 27.95, std 13.24) participated in the experiment to verify the usability of the interface. From object interception, subjects reported stable control inferred from intercepted objects more than 73% accurately. In a 2D maze, a comparison of male and female subjects reported a completion time of 98.84 s. ± 50.2 and 112.75 s. ± 44.2, respectively, without a significant difference in the mean of the one-way ANOVA (p = 0.519). The results confirmed the usefulness of neck sEMG of sternocleidomastoid (SCM) as a control interface with little or no calibration required. Control models using equations indicate intuitive direction and speed control, while machine learning schemes offer a more stable directional control. Control interfaces can be applied in several areas that involve neck activities, e.g., robot control and rehabilitation, as well as game interfaces, to enable entertainment for people with disabilities.

Verified
Journal Article
Open access
PDF file
JMJoseph Muguro
Joseph Muguro
Pringgo Widyo LaksonoPringgo Widyo Laksono
Pringgo Widyo Laksono
YSYuta Sasatake
Yuta Sasatake
KMKojiro Matsushita
Kojiro Matsushita
MSMinoru Sasaki
Minoru Sasaki
Background: As Automated Driving Systems (ADS) technology gets assimilated into the market, the driver’s obligation will be changed to a supervisory role. A key point to consider is the driver’s engagement in the secondary task to maintain the driver/user in the control loop. This paper aims to monitor driver engagement with a game and identify any impacts the task has on hazard recognition. Methods: We designed a driving simulation using Unity3D and incorporated three tasks: No-task, AR-Video, and AR-Game tasks. The driver engaged in an AR object interception game while monitoring the road for threatening road scenarios. Results: There was a significant difference in the tasks (F(2,33) = 4.34, p = 0.0213), identifying the game-task as significant with respect to reaction time and ideal for the present investigation. Game scoring followed three profiles/phases: learning, saturation, and decline profile. From the profiles, it is possible to quantify/infer drivers’ engagement with the game task. Conclusion: The paper proposes alternative monitoring that has utility, i.e., entertaining the user. Further experiments with AR-Games focusing on the real-world car environment will be performed to confirm the performance following the recommendations derived from the current test.

7 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YSYuta Sasatake
Yuta Sasatake
KMKojiro Matsushita
Kojiro Matsushita
The P300 event-related potential, evoked by attending to specific sensory stimuli, is utilized in non-invasive brain–computer interface (BCI) systems and is considered the only interface through which individuals with complete paralysis can operate devices based on their intention. Conventionally, visual stimuli used to elicit P300 have been presented using displays; however, placing a display directly in front of the user obstructs the field of view and prevents the user from perceiving their surrounding environment. Moreover, every time the user changes posture, the display must be repositioned accordingly, increasing the burden on caregivers. To address these issues, we propose a novel system that employs wirelessly controllable LED visual stimulus presentation devices distributed throughout the surrounding environment, rather than relying on traditional displays. The primary challenge in the proposed system is the communication delay associated with wireless control, which introduces errors in the timing of stimulus presentation—an essential factor for accurate P300 analysis. Therefore, it is necessary to evaluate how such delays affect P300 detection accuracy. The second challenge lies in the variability of visual stimulus strength due to differences in viewing distance caused by the spatial distribution of stimulus devices. This also requires the validation of its impact on P300 detection. In Experiment 1, we evaluated system performance in terms of wireless communication delay and confirmed an average delay of 352.1 ± 30.9 ms. In Experiment 2, we conducted P300 elicitation experiments using the wireless visual stimulus presentation device under conditions that allowed the precise measurement of stimulus presentation timing. We compared P300 waveforms across three conditions: (1) using the exact measured stimulus timing, (2) using the stimulus timing with a fixed compensation of 350 ms for the wireless delay, and (3) using the stimulus timing with both the 350 ms fixed delay compensation and an additional pseudo-random error value generated based on a normal distribution. The results demonstrated the effectiveness of the proposed delay compensation method in preserving P300 waveform integrity. In Experiment 3, a system performance verification test was conducted on 21 participants using a wireless visual presentation device. As a result, statistically significant differences (p < 0.01) in amplitude between target and non-target stimuli, along with medium or greater effect sizes (Cohen’s d: 0.49–0.61), were observed under all conditions with an averaging count of 10 or more. Notably, the P300 detection accuracy reached 85% with 40 averaging trials and 100% with 100 trials. These findings demonstrate that the system can function as a P300 speller and be utilized as an interface equivalent to conventional display-based methods.

14 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YSYuta Sasatake
Yuta Sasatake
KMKojiro Matsushita
Kojiro Matsushita
Enabling individuals with complete paralysis to operate devices voluntarily requires an effective interface; EEG-based P300 event-related potential (ERP) interfaces are considered a promising approach. P300 is an EEG peak generated in response to specific sensory stimuli recognized by an individual. Accurate detection of this peak necessitates a stable pre-stimulus baseline EEG signal, which serves as the reference for baseline correction. Previous studies have commonly employed either a single-time-point amplitude (e.g., at 100 ms before stimulus onset) or a time-range-averaged amplitude over a specified pre-stimulus period (e.g., 0–200 ms) as a baseline correction method, assuming these provide the most stable EEG reference. However, in assistive P300 interfaces, continuous visual stimuli at 400 ms intervals are typically used to efficiently evoke P300 peaks. Since stimuli are presented before the EEG stabilizes, it remains unclear whether conventional neuroscience baseline correction methods are suitable for such applications. To address this, the present study conducted a P300 induction experiment based on continuous 400 ms interval visual stimuli. Using EEG data recorded from 0 to 1000 ms before each visual stimulus (sampled at 1 ms intervals), we applied three baseline correction methods—single-time-point amplitude, time-range-averaged amplitude, and multi-time-point amplitude—to determine the most effective EEG reference and evaluate the impact on P300 detection performance. The results showed that baseline correction using an amplitude at a single point in time is unstable when the basic EEG rhythm and low-frequency noise remain, while time-range-averaged baseline correction using the 0–200 ms pre-stimulus period led to relatively effective P300 detection. However, it was also found that using only one value averaged over the amplitude from 0 to 200 ms did not result in an accurate EEG reference potential, resulting in an error. Finally, this study confirmed that the multi-time-point baseline correction method, through which the amplitude state from 0 to 200 ms before the visual stimulus is comprehensively evaluated, may be the most effective method for P300 determination.