Standard test methods may not be suitable or sufficient for determining the geotechnical conditions of a structure’s subsoil and the effects of the designed structures on the environment. Geophysical test methods, validated with other methods, may prove useful. In recent years they have found many new applications in engineering practice, both geotechnical and environmental. The advantages of geophysical methods include the non-destructive and non-invasive nature of the tests, their low costs and quick results, as well as compatibility with different materials, including soils, solid rocks, wastes and anthropogenic formations. The paper presents the analysis of laboratory and field investigations including research in a modified oedometer, resistivity chamber, electrical resistivity tomography (ERT) and resistivity cone penetration test (RCPT). Laboratory tests allowed for the assessment of the degree of saturation and porosity of sandy and clayey soils. The tests were carried out on saturated and unsaturated soil samples and allowed for the determination of some relationships between electrical conductivity and porosity. The proposed equations were used to assess parameters in in situ studies using RCPT tests and showed good agreement with reference values based on undisturbed soil samples. ERT tests confirmed the usefulness of electrical measurements in the quality assurance of subsoil and hydrotechnical structures. The tests showed weakening zones in the levee body, discontinuity of the vertical sealing system on the modernized section of the embankment, and location of the top of clay deposits.
Municipal solid waste landfilling, landfilling process and landfill reclamation result in leachate, which may be dangerous to the environment. Municipal solid waste leachate phytotoxicity tests were performed using the toxicity test and a subchronic toxicity pot experiment by direct application of leachate to reference soil in 5, 25, and 50% concentration for a period of 28 days. White mustard (Sinapis alba L.) seeds were exposed to different leachate dilution. Leachate were collected monthly in 2018 in the period from April to September. Furthermore, pH, conductivity, and dissolved oxygen were measured. The inhibition results on Sinapis alba L. seeds in the tested leachate samples ranged from −18.02 to 39.03%. Lower concentration of leachate showed a stimulating effect (only for Sample 1 and Sample 2 at 5% concentration). It was found out that leachate taken at the landfill is phytotoxic. The results of measurements are based on rainfall which affects the quantity and quality of the leachate. The values of germinated seeds/growing plants from the subchronic toxicity pot experiment ranged from 80 to 104%; therefore, the leachate is considered phytotoxic. However, it was confirmed that leachate may be used for landfill irrigation.
This study presents a flow pump technique usually used for evaluating the permeability of soils, which was, for first time, applied to measure the water permeability of concrete. Additionally, a new easy-to-apply method to determine permeability is proposed, based on a modification of Valenta’s formula. In the calculations, the apparent air content of concrete mixes was taken into account. An additional purpose of the conducted research was to determine the influence of a new generation of polycarboxylate superplasticizer and chemically active admixtures on the permeability, compressive strength, and other properties of concrete. The following four types of concrete were tested: concrete without admixtures, concrete with an admixture to increase the compressive strength, concrete with a superplasticizer, and concrete containing two admixtures simultaneously. The results showed that the proposed method allows to obtain reliable measurements within a very short period of time. The obtained results confirmed that new method may be very useful in engineering practice, particularly in terms of the watertightness of hydrotechnical concretes and the properties of the concretes used in bridge construction, underground parts of office buildings, or sealed tanks.
A fast reduction of a reservoir level may result in instability of an earth dam caused by the high pore water pressures that remain relatively high in the embankment. Moreover, the dissipation of the accumulated pore water pressures is highly dependent on the permeability of the materials used for the embankment and the storage characteristics of the reservoir. Therefore, in the design of embankment dams, the stability analysis under rapid drawdown loading conditions is an important design case. In this study, the influence of different permeability rates on dam stability under different cases of rapid drawdownwas investigated using the finite element method in SEEP/W and SLOPE/W of the GeoStudio with a case of the Lugoda dam in Ndembera catchment, Tanzania. The modeling process considers the time-dependent hydraulic conditions and the transient flow conditions using different water levels during rapid drawdown for evaluation of the factor of safety. From the 1m per day drawdown rate; the lowest minimum factor of safety value (0.90) was obtained from the 10 -7 m/s material permeability of the upstream zone of the dam. It means that, at a drawdown rate of 1m per day, there is a potential for failure of the embankment if the hydraulic conductivity value will be somewhere below 10 -6 m/s.
River embankments are the basic and the oldest measures of protecting areas potentially subjected to flooding, and at the same time pose a serious threat to their environment in the event of damage or failure. The technical condition of the levees and its regular evaluation is a key element of their safety. A general assessment of the technical condition of a levee is the result of many interacting factors and parameters that depend on each other to a varying degree. Therefore, it is necessary to consider the cause-and-effect links between the interrelationships of numerous parameters and sensors of significant impact. In this article the decision-making trial and evaluation laboratory (DEMATEL) method was applied to develop a cause-and-effect model for factors impacting the condition and safety of levees. Effective factors impacting the technical condition of a levee were identified; relationships between these factors were determined; a cause-and-effect model was developed based on identified factors; factors were categorized based on the dependence scale and influential indicators of each factors used in the DEMATEL method. The obtained results demonstrate that three following factors: hydrological factor, type and condition of soils in levee body and condition of levee areas (inter-levee and landside) play the most important role for levee safety. The results of this study can support traditional assessments of hydrotechnical structure or assist entities managing levees.