Mycoplasma synoviae (MS) is an important poultry pathogen worldwide. This bacterium may cause eggshell changes including an altered shell surface, thinning, and increased translucency in different areas, which leads to a greater incidence of eggshell cracks and breaks. In the present study the association between experimental infection of birds with two field strains of MS from different genotypes and the production of abnormal eggs is described. The analysis of those eggshells using a full-field optical coherence tomography (FF OCT) scanner is also reported. Eggshell samples were obtained from three experimental groups of chickens: one control and two infected tracheally with field strains of MS which produced abnormal eggs. In both experimental groups infected with MS a reduction of mean daily egg production by 11% was observed compared to the control group, which started at 21 to 42 dpi. Eggshell apex abnormalities increased to 24.5% of eggs and in some cases, soft-shelled eggs were produced. This study provides the first analysis of shells from anomalous eggs carried out using FF OCT, which allows three-dimensional structural imaging of an investigated sample at micrometre scale. FF OCT showed ultrastructural changes in eggshells and a smaller number of pores on the entire surface of the affected shells. The eggshell pathology and the concomitant egg production losses that result from infections highlight the economic significance of MS in commercial poultry. There are differences in the strains of MS which may induce eggshell apex abnormalities (EAA) and egg production losses. The use of FF OCT, which is a noninvasive measurement method based on analysis of the light backscattered from the measured object, will confer the ability to control the quality of eggshells in flocks infected with MS.
Low back and pelvic pain is one of the most frequently reported disorders in pregnancy, however etiology and pathology of this problem have not been fully determined. The relationship between back pain experienced during pregnancy and posture remains unclear. It is challenging to measure reliably postural and spinal changes at the time of pregnancy, since most imaging studies cannot be used due to the radiation burden. 3D shape measurement, or surface topography (ST), systems designed for posture evaluation could potentially fill this void. A pilot study was conducted to test the potential of monitoring the change of spine curvatures and posture during pregnancy using surface topography. A single case was studied to test the methodology and preliminarily assess the usefulness of the procedure before performing a randomized trial. The apparatus used in this study was metrologically tested and utilized earlier in scoliosis screening. The subject was measured using a custom-made structured light illumination scanner with accuracy of 0.2 mm. Measurement was taken every 2 weeks, between 17th and 37th week of pregnancy, 11 measurements in total. From the measurement the thoracic kyphosis and lumbar lordosis angles, and vertical balance angle were extracted automatically. Custom-written software was used for analysis. Oswestry Low Back Pain Disability Questionnaire (ODI) was done with every measurement. The values were correctly extracted from the measurement. The results were: 50.9 ± 2.4° for kyphosis angle, 58.1 ± 2.1° for lordosis angle and 4.7 ± 1.7° for vertical balance angle. The registered change was 7.4° in kyphosis angle, 8.4° in lordosis angle and 5.5° in vertical balance angle. The calculated ODI values were between moderate disability and severe disability (22 to 58 %). This case study presents that surface topography may be suitable for monitoring of spinal curvature and posture change in pregnant women. The ionizing radiation studies are contraindicated during pregnancy. Surface topography data connected with information from pain level questionnaires allows to investigate the connection between changes in posture and back pain.
Intensive research is currently being conducted on WAAM (Wire Arc Additive Manufacturing) processes. Previous studies have demonstrated the impact of current parameters on altering the structure and properties of 316L stainless steel. However, there is a lack of comprehensive information in the...
An algorithm for interpolation of central fringe position in low-coherence interferometry measurements is presented. The algorithm is based on a polynomial curve fitting. Fast calculation of interpolation is possible due to the use of an NVIDIA Compute Unified Device Architecture (CUDA) technology, which allows independent analysis of different points of a high-resolution detector matrix on separate cores of a graphics processing unit (GPU). The dependency of the method’s accuracy on the spectral width of the light source is checked. The computation times on a GPU are compared with those achieved with a multicore central processing unit, showing nearly 30 times faster calculations when using CUDA technology. The algorithm accuracy is tested by measuring a flat glass surface with two different cameras—an ordinary CCD camera and a cooled EMCCD camera. Finally, the algorithm is applied to measurements of a populated optical fiber connector array prototyped using deep proton writing technology.