24 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Gianluca DianaGianluca Diana
Gianluca Diana
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
SPSilvia Puleo
Silvia Puleo
Salvatore PastaSalvatore Pasta
Salvatore Pasta
LDLeonardo D'Acquisto
Leonardo D'Acquisto
With advancing age, blood vessels undergo deterioration that causes structural and functional changes, including a progressive increase in arterial wall stiffness. Since arterial stiffness is closely linked to the potential risks of cardiovascular diseases, which remains the leading cause of global mortality, it has become essential to develop effective techniques for early diagnosis and continuous monitoring over time. Photoplethysmography, a low-cost and non-invasive technology that measures blood volume changes, has gained increasing popularity in recent years and has proven to be a potential valuable tool for estimating arterial stiffness. This study employs an in vitro experimental setup designed to simulate the cardiovascular system performing under controlled velocity and pressure conditions, in which silicone phantom models with different geometric and mechanical properties were implemented to evaluate their stiffness using a pair of photoplethysmographic sensors. These were employed to measure the pulse wave velocity, currently considered the reference technique for estimating arterial stiffness, correlated through the well-known Moens–Korteweg equation. Photoplethysmographic sensors were placed at three specific distances to determine an optimal configuration for assessing arterial stiffness. Results showed the best performance for softer vascular models at a 15 cm sensor distance, with measurements demonstrating satisfactory accuracy. Variability and standard deviation values increased with model stiffness. The aim of this study is to improve the use of photoplethysmographic sensors for monitoring the mechanical properties of blood vessels and, therefore, to prevent potential cardiovascular diseases.

18 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
Gloria CosoliGloria Cosoli
Gloria Cosoli
CGCosmina Gnoffo
Cosmina Gnoffo
LALuca Antognoli
Luca Antognoli
FBFrancesco Bongiorno
Francesco Bongiorno
Marco ArnesanoMarco Arnesano
Marco Arnesano
Photoplethysmographic (PPG) sensors are small and cheap wearable sensors which open the possibility of monitoring physiological parameters such as heart rate during normal daily routines, ultimately providing valuable information on health status. Despite their potential and distribution within wearable devices, their accuracy is affected by several influencing parameters, such as contact pressure and physical activity. In this study, the effect of contact pressure (i.e., at 20, 60, and 75 mmHg) and intensity of physical activity (i.e., at 3, 6, and 8 km/h) were evaluated on a sample of 25 subjects using both a reference device (i.e., an electrocardiography-based device) and a PPG sensor applied to the skin with controlled contact pressure values. Results showed differing accuracy and precision when measuring the heart rate at different pressure levels, achieving the best performance at a contact pressure of 60 mmHg, with a mean absolute percentage error of between 3.36% and 6.83% depending on the physical activity levels, and a Pearson’s correlation coefficient of between 0.81 and 0.95. Plus, considering the individual optimal contact pressure, measurement uncertainty significantly decreases at any contact pressure, for instance, decreasing from 15 bpm (at 60 mmHg) to 8 bpm when running at a speed of 6 km/h (coverage factor k = 2). These results may constitute useful information for both users and manufacturers to improve the metrological performance of PPG sensors and expand their use in a clinical context.

12 June 2024
Verified
Conference Paper
Closed access
FSFrancesco Scardulla
Francesco Scardulla
CRClarissa Riggi
Clarissa Riggi
Gianluca DianaGianluca Diana
Gianluca Diana
LDLeonardo D'ACquisto
Leonardo D'ACquisto
Photoplethysmographic sensors represent a promising wearable technology as combines its advantages in costs and weight with a wide variety of cardiovascular parameters which can be detected. Despite their potential, the accuracy of heart rate and blood oxygenation measures are affected by several influencing parameters, including the skin temperature. Thus, a multiwavelength PPG sensor was tested in a cohort of 20 subjects to assess the influence of the external temperature in the measurements of heart rate. The performance of the PPG sensor was tested for 5 different temperatures (i.e. 15, 20, 25, 30 and 35°C) at two different measurement sites (at the tip of the finger and at the wrist). Data were subsequently analysed in Matlab and compared with those of a reference ECG-based chest-band. Preliminary results showed that the accuracy of the PPG sensor increases with temperature; specifically, the blue and green wavelengths showed the best overall performances. Red light proved to be the most sensitive to temperature variations and showed the worst overall performance. Although results should be confirmed on a larger cohort of subjects, this study could contribute with a useful indication to enhance the accuracy of PPG-based wearable devices.

26 November 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Gianluca DianaGianluca Diana
Gianluca Diana
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
SPSilvia Puleo
Silvia Puleo
Salvatore PastaSalvatore Pasta
Salvatore Pasta
LDLeonardo D'Acquisto
Leonardo D'Acquisto
Cardiovascular diseases represent the cause of 31% of all global deaths. Unfortunately, there are many difficulties in diagnosing them in a preventive, non-invasive and inexpensive way. However, there are important risk markers, including arterial stiffness. The current reference technique for assessing aortic stiffness is the measurement of Pulse Wave Velocity, and a commonly used mathematical model is the Moens–Korteweg equation, which relates Pulse Wave Velocity to arterial stiffness. A pair of photoplethysmographic sensors was used in this study to estimate Pulse Wave Velocity and, consequently, arterial stiffness on silicone phantom models with different geometric and mechanical properties. These models were placed in an experimental in vitro system that simulated the physiological conditions of a cardiovascular apparatus. The PPG sensors were positioned at three specific distances to determine a possible optimal distance for the estimation of arterial stiffness. The purpose of this study is to enhance the use of PPG sensors for monitoring the mechanical properties of blood vessels and, thus, to prevent potential cardiovascular pathologies.

7 November 2025 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Gianluca DianaGianluca Diana
Gianluca Diana
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
Salvatore PastaSalvatore Pasta
Salvatore Pasta
LDLeonardo D'Acquisto
Leonardo D'Acquisto
The second derivative of the photoplethysmographic signal presents five relevant points that provide information about the structural properties of arteries. This study investigates the ratio between the amplitude of the d wave (end of systole) and the a wave (beginning of systole) as a potential indicator of vascular aging. The research combines an in vitro study on silicone models with different stiffness and an in vivo study on volunteers aged between 26 and 63 years. The results show a strong negative correlation between the d/a ratio and arterial stiffness, confirming the potential of this parameter as a noninvasive index for assessing vascular health status.

26 November 2025
Verified
Conference Paper
Closed access
COCorin Otesteanu
Corin Otesteanu
Gianluca DianaGianluca Diana
Gianluca Diana
FSFrancesco Scardulla
Francesco Scardulla
SPSilvia Puleo
Silvia Puleo
SPSalvatore Pasta
Salvatore Pasta
CMCarlo Menon
Carlo Menon
The second derivative of the photoplethysmographic signal features characteristic peaks that provide information on vascular properties. Our analysis was conducted on deflection wave features of the second derivate of PPG signals from human volunteers aged between 26 to 63 years. We show that machine learning models can leverage these features to accurately distinguish subjects based on their age group in a binary classification approach, achieving a balanced accuracy of 80% and an AUC of 0.88 on unseen data, and 100% accuracy on a sample-level split. When including the ratios of deflection wave peaks in our feature set, accuracies of up to 89% and AUC of 0.95 were achieved. Our feature plot illustrates clear clustering between younger and older volunteers, specifically when using the peak ratios, confirming its discriminatory power and its significant potential as a non-invasive index for assessing vascular age. This study demonstrates that second derivative PPG peak ratios, together with the peak amplitudes, are a more robust marker of vascular age than the peak amplitudes alone.