Seventy cases of computed tomography (CT) data were selected from The Cancer Imaging Archive to aid in the design of a magnetically-guided capsule endoscope platform. According to the distance between the large bowel and the abdomen skin measured on CT images, the supine position showed the advantage in reducing the distance between internal and external magnets; thus, we used the supine position as the detection posture for magnetically-guided capsule colonoscopy. From the selected 70 cases of CT data, we chose 30 supine cases with different waistline lengths to extract the centerline of the large bowel as the motion trajectory of the capsule. We analyzed these trajectories to define the workspace of the capsule and simulated the motion of the capsule inside the large bowel. The distance between the large bowel and the abdomen surface, which can be regarded as the minimum distance of the internal and external magnets, was calculated and used as the reference for designing the magnet. Based on the abdomen volume and the workspace of the capsule, we provided a minimum workspace of the external magnet and designed an auxiliary degree of freedom for the manipulator to control the capsule to pass through the large bowel.

21 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YHYang Hao
Yang Hao
JLJing Li
Jing Li
FMFei Meng
Fei Meng
PZPeisen Zhang
Peisen Zhang
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
The capsule endoscopy robot can only use monocular vision due to the dimensional limit. To improve the depth perception of the monocular capsule endoscopy robot, this paper proposes a photometric stereo-based depth map reconstruction method. First, based on the characteristics of the capsule endoscopy robot system, a photometric stereo framework is established. Then, by combining the specular property and Lambertian property of the object surface, the depth of the specular highlight point is estimated, and the depth map of the whole object surface is reconstructed by a forward upwind scheme. To evaluate the precision of the depth estimation of the specular highlight region and the depth map reconstruction of the object surface, simulations and experiments are implemented with synthetic images and pig colon tissue, respectively. The results of the simulations and experiments show that the proposed method provides good precision for depth map reconstruction in monocular capsule endoscopy.

30 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PZPeisen Zhang
Peisen Zhang
JLJing Li
Jing Li
Weimin ZhangWeimin Zhang
Weimin Zhang
YHYang Hao
Yang Hao
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
A magnetically-guided capsule endoscope, embedding flexible force sensors, is designed to measure the capsule-tissue interaction force. The flexible force sensor is composed of eight force-sensitive elements surrounding the internal permanent magnet (IPM). The control of interaction force acting on the intestinal wall can reduce patient’s discomfort and maintain the magnetic coupling between the external permanent magnet (EPM) and the IPM during capsule navigation. A flexible force sensor can achieve this control. In particular, by analyzing the signals of the force sensitive elements, we propose a method to recognize the status of the motion of the magnetic capsule, and provide corresponding formulas to evaluate whether the magnetic capsule follows the motion of the external driving magnet. Accuracy of the motion recognition in Ex Vivo tests reached 94% when the EPM was translated along the longitudinal axis. In addition, a method is proposed to realign the EPM and the IPM before the loss of their magnetic coupling. Its translational error, rotational error, and runtime are 7.04 ± 0.71 mm, 3.13 ± 0.47∘, and 11.4 ± 0.39 s, respectively. Finally, a control strategy is proposed to prevent the magnetic capsule endoscope from losing control during the magnetically-guided capsule colonoscopy.

27 May 2020 in Robotica
Verified
Journal Article
Closed access
PDF file
LXLei Xu
Lei Xu
JLJing Li
Jing Li
YHYang Hao
Yang Hao
PZPeisen Zhang
Peisen Zhang
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
We present a 3D reconstruction method using brightness and camera motion estimation for registering local colon structure in colonoscopy. The proposed method is based on reverse projection from 2D fold contours to 3D space, motion estimation from 3D reconstructed points between neighboring frames, and model registration to reconstruct the fold structure. On the synthetic colon, the average percentages of the reconstructed depth error and circumference error are about 14.2% and 15.2%, respectively. The accuracy is enough for the navigation and control in capsule robot. This work demonstrates that the proposed method is superior to the methods using single-frame-based brightness intensity.

23 September 2020 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
PDF file
PZPeisen Zhang
Peisen Zhang
JLJing Li
Jing Li
YHYang Hao
Yang Hao
GCGastone Ciuti
Gastone Ciuti
TATatsuo Arai
Tatsuo Arai
PDPaolo Dario
Paolo Dario

30 April 2020 in Advanced Robotics
Verified
Journal Article
Closed access
YHYang Hao
Yang Hao
MVMarco Visentini-Scarzanella
Marco Visentini-Scarzanella
JLJing Li
Jing Li
PZPeisen Zhang
Peisen Zhang
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
For photometric stereo in capsule endoscopy, calibration of light source is crucial for improving the precision of surface normal estimation. Therefore, this paper presents an improved planar-mirror-based light source position calibration method: from captured images of light source and detected poses of planar mirror, light paths are retraced from camera to light source, and position of light source is triangulated with least square method. The contribution of this paper is that a refraction model of the planar mirror is employed in the retracement of light paths, thus the bias of light paths caused by refraction can be compensated and the position of light source can be estimated more precisely. The results of simulation and experiment show that the proposed method provides higher calibration accuracy than the current planar mirror-based calibration method and can improve the precision of subsequent photometric stereo-based 3D reconstruction.