Peisen Zhang

Dr. Peisen Zhang


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2025 in BMC Cancer
Verified
Journal Article
Open access
PDF file
LCLu Cao
Lu Cao
RHRuimin He
Ruimin He
AZAo Zhang
Ao Zhang
LLLingmei Li
Lingmei Li
WCwenfeng cao
wenfeng cao
PZPeisen Zhang
Peisen Zhang
Biochemical recurrence (BCR) occurs in 20%–40% of men with prostate cancer (PCa) who undergo radical prostatectomy. Predicting which patients will experience BCR in advance helps in formulating more targeted prostatectomy procedures. However, current preoperative recurrence prediction mainly relies on the use of the Gleason grading system, which omits within-grade morphological patterns and subtle histopathological features, leaving a significant amount of prognostic potential unexplored. We collected and selected a total of 1585 prostate biopsy images with tumor regions from 317 patients (5 Whole Slide Images per patient) to develop a deep learning system for predicting BCR of PCa before prostatectomy. The Inception_v3 neural network was employed to train and test models developed from patch-level images. The multiple instance learning method was used to extract whole slide image-level features. Finally, patient-level artificial intelligence models were developed by integrating deep learning -generated pathology features with several machine learning algorithms. The BCR prediction system demonstrated great performance in the testing cohort (AUC = 0.911, 95% Confidence Interval: 0.840–0.982) and showed the potential to produce favorable clinical benefits according to Decision Curve Analyses. Increasing the number of WSIs for each patient improves the performance of the prediction system. Additionally, the study explores the correlation between deep learning -generated features and pathological findings, emphasizing the interpretative potential of artificial intelligence models in pathology. Deep learning system can use biopsy samples to predict the risk of BCR in PCa, thereby formulating targeted treatment strategies.

23 March 2018 in Advanced Robotics
Verified
Journal Article
Closed access
PZPeisen Zhang
Peisen Zhang
JLJing Li
Jing Li
YHYang Hao
Yang Hao
FBFederico Bianchi
Federico Bianchi
GCGastone Ciuti
Gastone Ciuti
PDPaolo Dario
Paolo Dario
Seventy cases of computed tomography (CT) data were selected from The Cancer Imaging Archive to aid in the design of a magnetically-guided capsule endoscope platform. According to the distance between the large bowel and the abdomen skin measured on CT images, the supine position showed the advantage in reducing the distance between internal and external magnets; thus, we used the supine position as the detection posture for magnetically-guided capsule colonoscopy. From the selected 70 cases of CT data, we chose 30 supine cases with different waistline lengths to extract the centerline of the large bowel as the motion trajectory of the capsule. We analyzed these trajectories to define the workspace of the capsule and simulated the motion of the capsule inside the large bowel. The distance between the large bowel and the abdomen surface, which can be regarded as the minimum distance of the internal and external magnets, was calculated and used as the reference for designing the magnet. Based on the abdomen volume and the workspace of the capsule, we provided a minimum workspace of the external magnet and designed an auxiliary degree of freedom for the manipulator to control the capsule to pass through the large bowel.

21 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YHYang Hao
Yang Hao
JLJing Li
Jing Li
FMFei Meng
Fei Meng
PZPeisen Zhang
Peisen Zhang
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
The capsule endoscopy robot can only use monocular vision due to the dimensional limit. To improve the depth perception of the monocular capsule endoscopy robot, this paper proposes a photometric stereo-based depth map reconstruction method. First, based on the characteristics of the capsule endoscopy robot system, a photometric stereo framework is established. Then, by combining the specular property and Lambertian property of the object surface, the depth of the specular highlight point is estimated, and the depth map of the whole object surface is reconstructed by a forward upwind scheme. To evaluate the precision of the depth estimation of the specular highlight region and the depth map reconstruction of the object surface, simulations and experiments are implemented with synthetic images and pig colon tissue, respectively. The results of the simulations and experiments show that the proposed method provides good precision for depth map reconstruction in monocular capsule endoscopy.

30 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PZPeisen Zhang
Peisen Zhang
JLJing Li
Jing Li
Weimin ZhangWeimin Zhang
Weimin Zhang
YHYang Hao
Yang Hao
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
A magnetically-guided capsule endoscope, embedding flexible force sensors, is designed to measure the capsule-tissue interaction force. The flexible force sensor is composed of eight force-sensitive elements surrounding the internal permanent magnet (IPM). The control of interaction force acting on the intestinal wall can reduce patient’s discomfort and maintain the magnetic coupling between the external permanent magnet (EPM) and the IPM during capsule navigation. A flexible force sensor can achieve this control. In particular, by analyzing the signals of the force sensitive elements, we propose a method to recognize the status of the motion of the magnetic capsule, and provide corresponding formulas to evaluate whether the magnetic capsule follows the motion of the external driving magnet. Accuracy of the motion recognition in Ex Vivo tests reached 94% when the EPM was translated along the longitudinal axis. In addition, a method is proposed to realign the EPM and the IPM before the loss of their magnetic coupling. Its translational error, rotational error, and runtime are 7.04 ± 0.71 mm, 3.13 ± 0.47∘, and 11.4 ± 0.39 s, respectively. Finally, a control strategy is proposed to prevent the magnetic capsule endoscope from losing control during the magnetically-guided capsule colonoscopy.

5 November 2022 in Breast Cancer Research and Treatment
Verified
Journal Article
Closed access
PDF file
CLCao Lu
Cao Lu
YYYang Yang
Yang Yang
LLLi Lingmei
Li Lingmei
HQHuang Qiujuan
Huang Qiujuan
GQGuo Qianru
Guo Qianru
PZPeisen Zhang
Peisen Zhang

27 May 2020 in Robotica
Verified
Journal Article
Closed access
PDF file
LXLei Xu
Lei Xu
JLJing Li
Jing Li
YHYang Hao
Yang Hao
PZPeisen Zhang
Peisen Zhang
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
We present a 3D reconstruction method using brightness and camera motion estimation for registering local colon structure in colonoscopy. The proposed method is based on reverse projection from 2D fold contours to 3D space, motion estimation from 3D reconstructed points between neighboring frames, and model registration to reconstruct the fold structure. On the synthetic colon, the average percentages of the reconstructed depth error and circumference error are about 14.2% and 15.2%, respectively. The accuracy is enough for the navigation and control in capsule robot. This work demonstrates that the proposed method is superior to the methods using single-frame-based brightness intensity.