Yang Hao

Mr. Yang Hao

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2020 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
YHYang Hao
Yang Hao
JLJing Li
Jing Li
FBFederico Bianchi
Federico Bianchi
PZPeisen Zhang
Peisen Zhang
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
This work proposes a magnetic model for interaction forces and torques calculation between two permanent magnets applied in external magnetically-driven capsule endoscopies. The internal permanent magnet (IPM) embedded in the robotic capsule is characterized as a truncated cylinder which is beneficial to increase the efficiency of the internal space distribution of the capsule, especially for an active capsule robot integrated with medical functions like imaging, standard medical tool insertion, etc. In this paper, the second central moment is used first as the evaluation parameter to choose the shape of the IPM, i.e., the truncated cylinder, considering the demanding efficiency of the internal space of a capsule. Then, the analytical magnetic forces and torques model for the truncated cylinder-shaped permanent magnet has been reported and validated by comparison of results from the proposed magnetic model developed in MATLAB and the software of COMSOL Multiphysics. The experiments are presented in the end to demonstrate that the compact design of the capsule robot with a truncated cylinder-shaped IPM can work effectively and efficiently.

21 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YHYang Hao
Yang Hao
JLJing Li
Jing Li
FMFei Meng
Fei Meng
PZPeisen Zhang
Peisen Zhang
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
The capsule endoscopy robot can only use monocular vision due to the dimensional limit. To improve the depth perception of the monocular capsule endoscopy robot, this paper proposes a photometric stereo-based depth map reconstruction method. First, based on the characteristics of the capsule endoscopy robot system, a photometric stereo framework is established. Then, by combining the specular property and Lambertian property of the object surface, the depth of the specular highlight point is estimated, and the depth map of the whole object surface is reconstructed by a forward upwind scheme. To evaluate the precision of the depth estimation of the specular highlight region and the depth map reconstruction of the object surface, simulations and experiments are implemented with synthetic images and pig colon tissue, respectively. The results of the simulations and experiments show that the proposed method provides good precision for depth map reconstruction in monocular capsule endoscopy.

30 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PZPeisen Zhang
Peisen Zhang
JLJing Li
Jing Li
Weimin ZhangWeimin Zhang
Weimin Zhang
YHYang Hao
Yang Hao
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
A magnetically-guided capsule endoscope, embedding flexible force sensors, is designed to measure the capsule-tissue interaction force. The flexible force sensor is composed of eight force-sensitive elements surrounding the internal permanent magnet (IPM). The control of interaction force acting on the intestinal wall can reduce patient’s discomfort and maintain the magnetic coupling between the external permanent magnet (EPM) and the IPM during capsule navigation. A flexible force sensor can achieve this control. In particular, by analyzing the signals of the force sensitive elements, we propose a method to recognize the status of the motion of the magnetic capsule, and provide corresponding formulas to evaluate whether the magnetic capsule follows the motion of the external driving magnet. Accuracy of the motion recognition in Ex Vivo tests reached 94% when the EPM was translated along the longitudinal axis. In addition, a method is proposed to realign the EPM and the IPM before the loss of their magnetic coupling. Its translational error, rotational error, and runtime are 7.04 ± 0.71 mm, 3.13 ± 0.47∘, and 11.4 ± 0.39 s, respectively. Finally, a control strategy is proposed to prevent the magnetic capsule endoscope from losing control during the magnetically-guided capsule colonoscopy.

27 May 2020 in Robotica
Verified
Journal Article
Closed access
PDF file
LXLei Xu
Lei Xu
JLJing Li
Jing Li
YHYang Hao
Yang Hao
PZPeisen Zhang
Peisen Zhang
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
We present a 3D reconstruction method using brightness and camera motion estimation for registering local colon structure in colonoscopy. The proposed method is based on reverse projection from 2D fold contours to 3D space, motion estimation from 3D reconstructed points between neighboring frames, and model registration to reconstruct the fold structure. On the synthetic colon, the average percentages of the reconstructed depth error and circumference error are about 14.2% and 15.2%, respectively. The accuracy is enough for the navigation and control in capsule robot. This work demonstrates that the proposed method is superior to the methods using single-frame-based brightness intensity.

30 April 2020 in Advanced Robotics
Verified
Journal Article
Closed access
YHYang Hao
Yang Hao
MVMarco Visentini-Scarzanella
Marco Visentini-Scarzanella
JLJing Li
Jing Li
PZPeisen Zhang
Peisen Zhang
GCGastone Ciuti
Gastone Ciuti
QHQiang Huang
Qiang Huang
For photometric stereo in capsule endoscopy, calibration of light source is crucial for improving the precision of surface normal estimation. Therefore, this paper presents an improved planar-mirror-based light source position calibration method: from captured images of light source and detected poses of planar mirror, light paths are retraced from camera to light source, and position of light source is triangulated with least square method. The contribution of this paper is that a refraction model of the planar mirror is employed in the retracement of light paths, thus the bias of light paths caused by refraction can be compensated and the position of light source can be estimated more precisely. The results of simulation and experiment show that the proposed method provides higher calibration accuracy than the current planar mirror-based calibration method and can improve the precision of subsequent photometric stereo-based 3D reconstruction.

27 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YHYang Hao
Yang Hao
TTTao Tang
Tao Tang
CGChunhai Gao
Chunhai Gao
Train distance estimation in a turnout area is an important task for the autonomous driving of urban railway transit, since this function can assist trains in sensing the positions of other trains within the turnout area and prevent potential collision accidents. However, because of large incident angles on object surfaces and far distances, Lidar or stereo vision cannot provide satisfactory precision for such scenarios. In this paper, we propose a method for train distance estimation in a turnout area based on monocular vision: firstly, the side windows of trains in turnout areas are detected by instance segmentation based on YOLOv8; secondly, the vertical directions, the upper edges and lower edges of side windows of the train are extracted by feature extraction; finally, the distance to the target train is calculated with an appropriated pinhole camera model. The proposed method is validated by practical data captured from Hong Kong Metro Tsuen Wan Line. A dataset of 2477 images is built to train the instance segmentation neural network, and the network is able to attain an MIoU of 92.43% and a MPA of 97.47% for segmentation. The accuracy of train distance estimation is then evaluated in four typical turnout area scenarios with ground truth data from on-board Lidar. The experiment results indicate that the proposed method achieves a mean RMSE of 0.9523 m for train distance estimation in four typical turnout area scenarios, which is sufficient for determining the occupancy of crossover in turnout areas.