Aleksandar Jevtic

Aleksandar Jevtic


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Stefan D. IlićStefan D. Ilić
Stefan D. Ilić
AJAleksandar Jevtic
Aleksandar Jevtic
SSSrboljub Stanković
Srboljub Stanković
Goran S. RistićGoran S. Ristić
Goran S. Ristić
This paper describes the possibility of using an Electrically Programmable Analog Device (EPAD) as a gamma radiation sensor. Zero-biased EPAD has the lowest fading and the highest sensitivity in the 300 Gy dose range. Dynamic bias of the control gate during irradiation was presented for the first time; this method achieved higher sensitivity compared to static-biased EPADs and better linear dependence. Due to the degradation of the transfer characteristics of EPAD during irradiation, a function of the safe operation area has been found that determines the maximum voltage at the control gate for the desired dose, which will not lead to degradation of the transistor. Using an energy band diagram, it was explained why the zero-biased EPAD has higher sensitivity than the static-biased EPAD.

16 March 2022 in Electronics
Verified
Journal Article
Open access
PDF file
Goran S. RistićGoran S. Ristić
Goran S. Ristić
Stefan D. IlićStefan D. Ilić
Stefan D. Ilić
Sandra VeljkovicSandra Veljkovic
Sandra Veljkovic
AJAleksandar Jevtic
Aleksandar Jevtic
SDStrahinja Dimitrijević
Strahinja Dimitrijević
MAMarko Andjelkovic
Marko Andjelkovic
The possibility of using commercial p-channel power vertical double-diffused metal-oxide-semiconductor field-effect transistors (VDMOSFETs) as X-ray sensors is investigated in this case study. In this aspect, the dependence of sensitivity on both the gate voltage and the mean energy for three X-ray beams is examined. The eight gate voltages from 0 to 21 V are applied, and the dependence of the sensitivity on the gate voltage is well fitted using the proposed equation. Regarding X-ray energy, the sensitivity first increases and then decreases as a consequence of the behavior of the mass energy-absorption coefficients and is the largest for RQR8 beam. As the mass energy-absorption coefficients of SiO2 are not found in the literature, the mass energy-absorption coefficients of silicon are used. The behavior of irradiated transistors during annealing at room temperature without gate polarization is also considered.

16 March 2022 in Royal Society Open Science
Verified
Journal Article
Open access
JBJan Buytaert
Jan Buytaert
PCPaula Collins
Paula Collins
AAAdam Abed Abud
Adam Abed Abud
PAPhil Allport
Phil Allport
AÁAntonio Pazos Álvarez
Antonio Pazos Álvarez
KWKen Wyllie
Ken Wyllie
A high-quality, low-cost ventilator, dubbed HEV, has been developed by the particle physics community working together with biomedical engineers and physicians around the world. The HEV design is suitable for use both in and out of hospital intensive care units, provides a variety of modes and is capable of supporting spontaneous breathing and supplying oxygen-enriched air. An external air supply can be combined with the unit for use in situations where compressed air is not readily available. HEV supports remote training and post market surveillance via a Web interface and data logging to complement standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the ventilation performance, especially the quality and accuracy of the pressure curves, reactivity of the trigger, measurement of delivered volume and control of oxygen mixing, delivering a global performance which will be applicable to ventilator needs beyond the COVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with a performance evaluation.