Yeying Chen

Ms. Yeying Chen

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
GCGabriella Crotti
Gabriella Crotti
YCYeying Chen
Yeying Chen
HÇHuseyin Çayci
Huseyin Çayci
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
Carmine LandiCarmine Landi
Carmine Landi
HBHelko van den Brom
Helko van den Brom
The integration of renewable energy sources on a large scale in the electrical energy distribution systems, as well as the widespread of non-linear loads, has led to a significant increase in power quality (PQ) disturbances. For this reason, PQ monitoring is also becoming a key task in medium voltage (MV) grids. The measurement of PQ at MV levels can only be performed using instrument transformers (ITs) to scale down the level of voltage and current to levels suitable for the input stage of PQ instruments. However, no international standards currently require the verification of the errors introduced by ITs in the measurement of PQ phenomena. Moreover, this issue is only partially addressed in the scientific literature, where papers dealing with specific and limited aspects of the problem can be found. For this reason, this paper aims to comprehensively assess the issue, proposing IT accuracy verification tests for different PQ parameters. First, a set of PQ phenomena relevant for IT testing is chosen, as well as the associated ranges of variation, based on a review of the enforced standards and the scientific literature. For each selected PQ phenomenon, possible performance indices and test waveforms are proposed. Finally, the proposed procedure is validated by applying it to the characterization of two different types of commercial voltage transformers.

12 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PLPalma Sara Letizia
Palma Sara Letizia
GCGabriella Crotti
Gabriella Crotti
Alessandro MingottiAlessandro Mingotti
Alessandro Mingotti
ROBERTO TINARELLIROBERTO TINARELLI
ROBERTO TINARELLI
YCYeying Chen
Yeying Chen
RSRobert Stiegler
Robert Stiegler
Instrument transformers (ITs) play a key role in electrical power systems, facilitating the accurate monitoring and measurement of electrical quantities. They are essential for measurement, protection, and metering in transmission and distribution grids and accurately reducing the grid voltage and current for low-voltage input instrumentation. With the increase in renewable energy sources, electronic converters, and electric vehicles connected to power grids, ITs now face challenging distorted conditions that differ from the nominal ones. The study presented in this paper is a collaborative work between national metrology institutes and universities that analyzes IT performance in measuring distorted voltages and currents in medium-voltage grids under realistic conditions. Both current and voltage measuring transformers are examined, considering influence quantities like the temperature, mechanical vibration, burden, adjacent phases, and proximity effects. The study provides detailed insights into measurement setups and procedures, and it quantifies potential errors arising from IT behavior in measuring distorted signals in the presence of the various considered influence quantities and their combinations. The main findings reveal that the temperature has the most evident impact on the inductive voltage transformer performance, as well as the burden, causing significant changes in ratio error and phase displacement at the lower temperatures. As for low-power ITs, establishing a priori the effects of adjacent phases and proximity on the frequency responses of low-power ITs is a complex matter, because of their different characteristics and construction solutions.

21 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YCYeying Chen
Yeying Chen
EMEnrico Mohns
Enrico Mohns
MSMichael Seckelmann
Michael Seckelmann
SRSoeren de Rose
Soeren de Rose
Sampling-based calibration systems for calibrating “Sampled Value” (SV)-based instruments for substation automation require synchronised and time-aligned sampling processes. As the signal frequency of the power grid is always asynchronous to the standardised sampling frequencies according to IEC 61869-9, the sampled waveforms of the calibration system and of the SV-based device under test can be resampled to be synchronised and to allow better accuracy in the following measurements based on the Discrete Fourier Transform (DFT) of the resampled waveforms. The paper presents simulations and results for different resampling algorithms. A modified sinc interpolation method with a finite impulse response (FIR) is presented. The deviation of the results for the root mean square (RMS) and phase angle is in the order of 10−8V/V (or rad) for normalised frequencies of up to 20% of the sampling frequency. No practical degradation in the presence of noise and harmonics could be observed. In addition, laboratory experiments demonstrate the realization of the proposed resampling process in the future SV-based calibration systems for SV-based instrumentation.