The measurement of harmonics is one of the key tasks in modern power systems, performed basically for power quality assessment, verification of planning levels compliance, immunity and compatibility purposes, and so on. Especially at medium voltage (MV) and high voltage (HV) levels, harmonics are always measured through voltage and current transformers (VTs and CTs), which very often are inductive. Recent articles show that inductive VTs and CTs, due to the intrinsic iron core nonlinearity, can introduce errors up to some percent in harmonic measurements. This article aims to investigate in-depth this phenomenon by analyzing how the accuracy of harmonic measurements performed through an inductive MV VT is affected by the presence subharmonics in its input voltage. Subharmonics are spectral components having frequencies lower than the power frequency, that is 50 Hz for European countries. Some theoretical considerations are carried out and the performances of two different inductive MV VTs are tested in various operating conditions. Experimental results show that subharmonics can worsen the harmonic measurements done through inductive VTs up to some tens of percent.

4 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
GCGabriella Crotti
Gabriella Crotti
YCYeying Chen
Yeying Chen
HÇHuseyin Çayci
Huseyin Çayci
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
Carmine LandiCarmine Landi
Carmine Landi
HBHelko van den Brom
Helko van den Brom
The integration of renewable energy sources on a large scale in the electrical energy distribution systems, as well as the widespread of non-linear loads, has led to a significant increase in power quality (PQ) disturbances. For this reason, PQ monitoring is also becoming a key task in medium voltage (MV) grids. The measurement of PQ at MV levels can only be performed using instrument transformers (ITs) to scale down the level of voltage and current to levels suitable for the input stage of PQ instruments. However, no international standards currently require the verification of the errors introduced by ITs in the measurement of PQ phenomena. Moreover, this issue is only partially addressed in the scientific literature, where papers dealing with specific and limited aspects of the problem can be found. For this reason, this paper aims to comprehensively assess the issue, proposing IT accuracy verification tests for different PQ parameters. First, a set of PQ phenomena relevant for IT testing is chosen, as well as the associated ranges of variation, based on a review of the enforced standards and the scientific literature. For each selected PQ phenomenon, possible performance indices and test waveforms are proposed. Finally, the proposed procedure is validated by applying it to the characterization of two different types of commercial voltage transformers.

10 February 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
Marco FaiferMarco Faifer
Marco Faifer
Carmine LandiCarmine Landi
Carmine Landi
Christian LauranoChristian Laurano
Christian Laurano
PLPalma Sara Letizia
Palma Sara Letizia
Sergio ToscaniSergio Toscani
Sergio Toscani
Inductive instrument transformers (ITs) are still the most used voltage and current sensors in power systems. Among the numerous applications that require their use, one of the most important is surely represented by harmonics measurement. In this case, the recent literature shows that, since they suffer from both a filtering behavior due to their dynamics and from nonlinear effects produced by their iron core, they can introduce errors up to some percent. This article wants to deeply investigate, in the very same experimental conditions, about the performance of two digital signal processing techniques, recently introduced for the improvement of harmonics measurements performed through ITs, namely, SINusoidal characterization for DIstortion COMPensation (SINDICOMP) and compensation of harmonic distortion through polynomial modeling in the frequency domain (PHD). These methods have been applied to two different voltage transformers, having different specifications, by using two measurement setups based on different architectures. The impact of the voltage generator employed during the identification on the achieved accuracy is theoretically and experimentally evaluated. Modified versions of SINDICOMP and PHD compensation, which are more robust against nonidealities of the measurement setup, are presented. The performances of the techniques are evaluated by adopting voltage waveforms similar to those that can be encountered during the normal operation in a real distribution grid.

1 April 2020 in Measurement
Verified
Journal Article
Open access
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
AFA. Delle Femine
A. Delle Femine
Daniele GalloDaniele Gallo
Daniele Gallo
CLC. Landi
C. Landi
MLM. Luiso
M. Luiso

1 September 2021 in Measurement
Verified
Journal Article
Open access
GCG. Crotti
G. Crotti
DGD. Giordano
D. Giordano
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
PLP.S. Letizia
P.S. Letizia
MLM. Luiso
M. Luiso

19 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
GCGabriella Crotti
Gabriella Crotti
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
DGDomenico Giordano
Domenico Giordano
PLPalma Sara Letizia
Palma Sara Letizia
MLMario Luiso
Mario Luiso
The paper presents a method for the frequency characterization of voltage transformers (VTs) for medium voltage (MV) grids which involves only sine waves. It is called extended SINDICOMP, since it is an extended version of the previously developed technique SINDICOMP. It requires, in the first step, an evaluation and a compensation of the non-linearity introduced by the VT when it is supplied with a 50 Hz sinusoidal input at rated value. Then, the VT is characterized with a low voltage sinusoidal frequency sweep from the second harmonic frequency up to the first resonance frequency. Some rules to build the approximated frequency response, starting from these two sets of data, are given in the paper. The proposed approach is applied to three commercial MV VTs. Significant improvement of the VT performance is obtained, compared to the use of a frequency response obtained from the low voltage characterization.