24 September 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
GCGabriella Crotti
Gabriella Crotti
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
PLPalma Sara Letizia
Palma Sara Letizia
MLMario Luiso
Mario Luiso
The measurement of harmonics is one of the key tasks in modern power systems, performed basically for power quality assessment, verification of planning levels compliance, immunity and compatibility purposes, and so on. Especially at medium voltage (MV) and high voltage (HV) levels, harmonics are always measured through voltage and current transformers (VTs and CTs), which very often are inductive. Recent articles show that inductive VTs and CTs, due to the intrinsic iron core nonlinearity, can introduce errors up to some percent in harmonic measurements. This article aims to investigate in-depth this phenomenon by analyzing how the accuracy of harmonic measurements performed through an inductive MV VT is affected by the presence subharmonics in its input voltage. Subharmonics are spectral components having frequencies lower than the power frequency, that is 50 Hz for European countries. Some theoretical considerations are carried out and the performances of two different inductive MV VTs are tested in various operating conditions. Experimental results show that subharmonics can worsen the harmonic measurements done through inductive VTs up to some tens of percent.

4 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
GCGabriella Crotti
Gabriella Crotti
YCYeying Chen
Yeying Chen
HÇHuseyin Çayci
Huseyin Çayci
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
Carmine LandiCarmine Landi
Carmine Landi
HBHelko van den Brom
Helko van den Brom
The integration of renewable energy sources on a large scale in the electrical energy distribution systems, as well as the widespread of non-linear loads, has led to a significant increase in power quality (PQ) disturbances. For this reason, PQ monitoring is also becoming a key task in medium voltage (MV) grids. The measurement of PQ at MV levels can only be performed using instrument transformers (ITs) to scale down the level of voltage and current to levels suitable for the input stage of PQ instruments. However, no international standards currently require the verification of the errors introduced by ITs in the measurement of PQ phenomena. Moreover, this issue is only partially addressed in the scientific literature, where papers dealing with specific and limited aspects of the problem can be found. For this reason, this paper aims to comprehensively assess the issue, proposing IT accuracy verification tests for different PQ parameters. First, a set of PQ phenomena relevant for IT testing is chosen, as well as the associated ranges of variation, based on a review of the enforced standards and the scientific literature. For each selected PQ phenomenon, possible performance indices and test waveforms are proposed. Finally, the proposed procedure is validated by applying it to the characterization of two different types of commercial voltage transformers.

12 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PLPalma Sara Letizia
Palma Sara Letizia
GCGabriella Crotti
Gabriella Crotti
Alessandro MingottiAlessandro Mingotti
Alessandro Mingotti
ROBERTO TINARELLIROBERTO TINARELLI
ROBERTO TINARELLI
YCYeying Chen
Yeying Chen
RSRobert Stiegler
Robert Stiegler
Instrument transformers (ITs) play a key role in electrical power systems, facilitating the accurate monitoring and measurement of electrical quantities. They are essential for measurement, protection, and metering in transmission and distribution grids and accurately reducing the grid voltage and current for low-voltage input instrumentation. With the increase in renewable energy sources, electronic converters, and electric vehicles connected to power grids, ITs now face challenging distorted conditions that differ from the nominal ones. The study presented in this paper is a collaborative work between national metrology institutes and universities that analyzes IT performance in measuring distorted voltages and currents in medium-voltage grids under realistic conditions. Both current and voltage measuring transformers are examined, considering influence quantities like the temperature, mechanical vibration, burden, adjacent phases, and proximity effects. The study provides detailed insights into measurement setups and procedures, and it quantifies potential errors arising from IT behavior in measuring distorted signals in the presence of the various considered influence quantities and their combinations. The main findings reveal that the temperature has the most evident impact on the inductive voltage transformer performance, as well as the burden, causing significant changes in ratio error and phase displacement at the lower temperatures. As for low-power ITs, establishing a priori the effects of adjacent phases and proximity on the frequency responses of low-power ITs is a complex matter, because of their different characteristics and construction solutions.

10 February 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
Marco FaiferMarco Faifer
Marco Faifer
Carmine LandiCarmine Landi
Carmine Landi
Christian LauranoChristian Laurano
Christian Laurano
PLPalma Sara Letizia
Palma Sara Letizia
Sergio ToscaniSergio Toscani
Sergio Toscani
Inductive instrument transformers (ITs) are still the most used voltage and current sensors in power systems. Among the numerous applications that require their use, one of the most important is surely represented by harmonics measurement. In this case, the recent literature shows that, since they suffer from both a filtering behavior due to their dynamics and from nonlinear effects produced by their iron core, they can introduce errors up to some percent. This article wants to deeply investigate, in the very same experimental conditions, about the performance of two digital signal processing techniques, recently introduced for the improvement of harmonics measurements performed through ITs, namely, SINusoidal characterization for DIstortion COMPensation (SINDICOMP) and compensation of harmonic distortion through polynomial modeling in the frequency domain (PHD). These methods have been applied to two different voltage transformers, having different specifications, by using two measurement setups based on different architectures. The impact of the voltage generator employed during the identification on the achieved accuracy is theoretically and experimentally evaluated. Modified versions of SINDICOMP and PHD compensation, which are more robust against nonidealities of the measurement setup, are presented. The performances of the techniques are evaluated by adopting voltage waveforms similar to those that can be encountered during the normal operation in a real distribution grid.

19 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
GCGabriella Crotti
Gabriella Crotti
Giovanni D'AvanzoGiovanni D'Avanzo
Giovanni D'Avanzo
DGDomenico Giordano
Domenico Giordano
PLPalma Sara Letizia
Palma Sara Letizia
MLMario Luiso
Mario Luiso
The paper presents a method for the frequency characterization of voltage transformers (VTs) for medium voltage (MV) grids which involves only sine waves. It is called extended SINDICOMP, since it is an extended version of the previously developed technique SINDICOMP. It requires, in the first step, an evaluation and a compensation of the non-linearity introduced by the VT when it is supplied with a 50 Hz sinusoidal input at rated value. Then, the VT is characterized with a low voltage sinusoidal frequency sweep from the second harmonic frequency up to the first resonance frequency. Some rules to build the approximated frequency response, starting from these two sets of data, are given in the paper. The proposed approach is applied to three commercial MV VTs. Significant improvement of the VT performance is obtained, compared to the use of a frequency response obtained from the low voltage characterization.

16 August 2022 in IEEE Open Journal of Instrumentation and Measurement
Verified
Journal Article
Open access
GCGabriella Crotti
Gabriella Crotti
GDGiovanni D'AVanzo
Giovanni D'AVanzo
Carmine LandiCarmine Landi
Carmine Landi
PLPalma Sara Letizia
Palma Sara Letizia
MLMario Luiso
Mario Luiso
The measurement of Power Quality (PQ), generally performed at Low Voltage (LV) level, is gaining more and more importance also at the Medium Voltage (MV) level, due to the increasing presence of switching power converters (both loads or generators) directly connected to MV grids. In this case, the use of Voltage Transformers (VTs) is unavoidable to scale voltage down to amplitudes compatible with the input ranges of PQ instruments. However, the current absence of an international standard dealing with VTs used for PQ measurements leaves the manufacturers and the users in a situation of complete uncertainty, since different products can have performance specifications tested and stated in completely different ways. This paper aims at defining an integrated approach for the evaluation of VTs accuracy used for PQ measurements, focusing on harmonics and interharmonics. The paper provides experimental results of the tests performed on a MV inductive VT according to the proposed procedure. As a result, it is demonstrated that VT accuracy in the measurement of a specific phenomenon should be evaluated with complex waveforms including the contemporary presence of different PQ phenomena.