Muhammad Saufi Kamarudin

Dr. Muhammad Saufi Kamarudin

Universiti Tun Hussein Onn Malaysia
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Salem Mgammal Al-AmeriSalem Mgammal Al-Ameri
Salem Mgammal Al-Ameri
MKMuhammad Saufi Kamarudin
Muhammad Saufi Kamarudin
MYMohd Fairouz Mohd Yousof
Mohd Fairouz Mohd Yousof
ASAli Salem
Ali Salem
Ahmed Abu-SiadaAhmed Abu-Siada
Ahmed Abu-Siada
Mohamed MosaadMohamed Mosaad
Mohamed Mosaad
Frequency response analysis (FRA) is a method of monitoring a power transformer’s mechanical integrity. However, identifying the type of fault and its severity by comparing measured responses is still challenging and mostly relies on personnel expertise. This paper is taking one step forward to standardize the FRA interpretation process by proposing guidelines based on various international standards and FRA case studies. In this study, the FRA signature is divided into three regions: low-, mid- and high-frequency regions. The deviation from the fingerprint signature for various faults is classified into small, large, and no variations, based on the calculation of the correlation coefficient. The proposed guidelines are developed based on the frequency regions, and the level of variation is represented using a simple arrow method to simplify the interpretation process. A case study is conducted on a three-phase 11/0.433 kV, 500 kVA distribution transformer with a short circuit winding fault to validate the proposed guidelines.

1 December 2008
Verified
Conference Paper
Closed access
APAsmarashid Ponniran
Asmarashid Ponniran
MKMuhammad Saufi Kamarudin
Muhammad Saufi Kamarudin
Performance of underground XLPE cables in service is critical because of ageing mechanisms influences. One of the techniques to evaluate performance of aged and unaged underground XLPE cables is based on tan delta and capacitance measurements of the cable insulations. This study focuses on underground XLPE cables which rated at 11 kV and 22 kV for both 1-core and 3-core types. Tan delta and capacitance data of underground XLPE cables are obtained using a Schering bridge instrument. Tan delta and capacitance measurements are performed at ambient temperature (about 27degC) and 50 Hz power frequency. The analysis of data show that tan delta values increased in proportion to the aging time of the cables. Meanwhile the data analysis of the capacitance measurement shows that the values of capacitance inconsistent. Nevertheless, tan delta measurement is more accurate and appropriate parameter for evaluating performance of underground XLPE cables as compared to capacitance parameter. Therefore, the finding of this study shows that aging mechanisms contributes the deteriorations of underground XLPE cable insulations in service and consequently the value of tan delta increases with aging time of the cables.

12 November 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SISyed Zahurul Islam
Syed Zahurul Islam
MOMohammad Lutfi Othman
Mohammad Lutfi Othman
MKMuhammad Saufi Kamarudin
Muhammad Saufi Kamarudin
RORosli Omar
Rosli Omar
Arash ToudeshkiArash Toudeshki
Arash Toudeshki
This study analyzes the performance of two PV modules, amorphous silicon (a-Si) and crystalline silicon (c-Si) and predicts energy yield, which can be seen as facilitation to achieve the target of 35% reduction of greenhouse gases emission by 2030. Malaysia Energy Commission recommends crystalline PV modules for net energy metering (NEM), but the climate regime is a concern for output power and efficiency. Based on rainfall and irradiance data, this study aims to categorize the climate of peninsular Malaysia into rainy and dry seasons; and then the performance of the two modules are evaluated under the dry season. A new mathematical model is developed to predict energy yield and the results are validated through experimental and systematic error analysis. The parameters are collected using a self-developed ZigBeePRO-based wireless system with the rate of 3 samples/min over a period of five days. The results unveil that efficiency is inversely proportional to the irradiance due to negative temperature coefficient for crystalline modules. For this phenomenon, efficiency of c-Si (9.8%) is found always higher than a-Si (3.5%). However, a-Si shows better shadow tolerance compared to c-Si, observed from a lesser decrease rate in efficiency of the former with the increase in irradiance. Due to better spectrum response and temperature coefficient, a-Si shows greater performance on output power efficiency (OPE), performance ratio (PR), and yield factor. From the regression analysis, it is found that the coefficient of determination (R2) is between 0.7179 and 0.9611. The energy from the proposed model indicates that a-Si yields 15.07% higher kWh than c-Si when luminance for recorded days is 70% medium and 30% high. This study is important to determine the highest percentage of energy yield and to get faster NEM payback period, where as of now, there is no such model to indicate seasonal energy yield in Malaysia.

1 October 2017
Verified
Conference Paper
Closed access
Ali Ahmed SalemAli Ahmed Salem
Ali Ahmed Salem
Rahisham Abd RahmanRahisham Abd Rahman
Rahisham Abd Rahman
MKMuhammad Saufi Kamarudin
Muhammad Saufi Kamarudin
NON. A. Othman
N. A. Othman
This paper reviews pollution flashover phenomenon on high voltage outdoor insulators, focusing on modeling approaches for analysing flashover behavior other than influential factors affecting pollution performance. Previously proposed dynamic and static flashover models by well-known researchers i.e. Obenaus, Neumarker, Wilkin, Claverie etc. have been compared and evaluated. Resistance and conductivity of pollution layer have been simulated by using the proposed models. The results for all models reveal the same trend of plot with good consistency indicating reliable modeling technique for pollution flashover. The best pollution model which giving close agreement to the experimental results also been suggested in this articles.

11 December 2018 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
ASAli. A. Salem
Ali. A. Salem
Rahisham Abd RahmanRahisham Abd Rahman
Rahisham Abd Rahman
MKMuhammad Saufi Kamarudin
Muhammad Saufi Kamarudin
HAH. Ahmad
H. Ahmad
NJN.A.M. Jamail
N.A.M. Jamail
Salem Mgammal Al-AmeriSalem Mgammal Al-Ameri
Salem Mgammal Al-Ameri
Glass insulators, due to its diverse characteristics, were used widely around the world for high voltage transmission lines. Surfaces of the insulators are exposed to high electrical, mechanical, and thermal stresses over the period of service. Accumulation of contamination distort stresses distribution along the insulators that may lead to flashover under severe condition. In this paper, Obenaus pollution model has been adopted to propose a dynamic mathematical modelling to determine flashover critical voltage with regard to parameters such as pollution conductivity, arc length, and width of layer of contamination on the surface of glass insulator. In addition, laboratory experimental works have been carried out according to IEC60305 to validate the results from numerical approach, which indicate a good agreement.

8 September 2016 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Open access
LCLujia Chen
Lujia Chen
HGH. Griffiths
H. Griffiths
AHA. Haddad
A. Haddad
MKMuhammad Saufi Kamarudin
Muhammad Saufi Kamarudin
SF6 is widely used in modern transmission and distribution networks because of its outstanding dual qualities: arc quenching and dielectric insulation. As a gas medium, SF6 is chemically inert, non-toxic, and non-flammable, which makes possible the construction of compact SF6 switchgear. One major known disadvantage of the gas is that it has a global warming potential which is 23,900 times higher than CO2. This has led to research into alternative gases with a much lower environmental impact, and one of the emerging candidates is CF3I. The high boiling temperature of CF3I means that it has to be used as part of a mixture inside gas-insulated equipment. To carry out the investigation on CF3I, a scaled-down coaxial system that replicates the maximum electric field of a 400 kV GIL system was designed and fabricated. The insulation performances of CF3I/CO2 and CF3I/N2 gas mixtures were then examined by measuring the 50% breakdown voltage, U50, using a standard lightning impulse waveform (1.2/50) under absolute pressures of 1 to 4 bar. The experimental results show that CF3I gas mixtures have promising potential as an insulation medium for application in gasinsulated lines.