Yoon-Seong Lee

Mr. Yoon-Seong Lee

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2021 in Electronics
Verified
Journal Article
Open access
PDF file
KKKang Kyungmin
Kang Kyungmin
BCBong-Yeon Choi
Bong-Yeon Choi
HLHoon Lee
Hoon Lee
CAChang-Gyun An
Chang-Gyun An
TKTae-Gyu Kim
Tae-Gyu Kim
CWChung-Yuen Won
Chung-Yuen Won
This paper proposes an artificial neural network (ANN)-based energy management system (EMS) for controlling power in AC–DC hybrid distribution networks. The proposed ANN-based EMS selects an optimal operating mode by collecting data such as the power provided by distributed generation (DG), the load demand, and state of charge (SOC). For training the ANN, profile data on the charging and discharging amount of ESS for various distribution network power situations were prepared, and the ANN was trained with an error rate within 10%. The proposed EMS controls each power converter in the optimal operation mode through the already trained ANN in the grid-connected mode. For the experimental verification of the proposed EMS, a small-scale hybrid AD/DC microgrid was fabricated, and simulations and experiments were performed for each operation mode.

22 November 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HBHyung-Jun Byun
Hyung-Jun Byun
SKSung-Hun Kim
Sung-Hun Kim
YLYoon-Seong Lee
Yoon-Seong Lee
JYJunsin Yi
Junsin Yi
CWChung-Yuen Won
Chung-Yuen Won
The main assignment of a bipolar dc microgrid is the settlement of the bipolar voltage imbalance due to unbalanced loads and asymmetric powers. It is necessary to consider maintaining the bipolar systems whether in grid-connected mode or islanded mode of the microgrid. This article introduces the control strategy of the triple-active-bridge (TAB) converter for the bipolar dc microgrid by voltage balancing. The presented control strategy performs PN voltage regulation and voltage balancing based on the interrelation analysis between power and voltage in the bipolar dc microgrid. With the separately configured voltage balancing loop in the controller, the active voltage balancing through the power transfer between the bipolar buses is ensured even in the islanded mode without additional circuit components. The TAB converter operates with phase-shift modulation as conventional, and the control strategy is implemented through the digital signal processor. The validity of the proposal is verified by lab-scale experimental results.

11 February 2022 in IEEE Access
Verified
Journal Article
Open access
CAChang-Gyun An
Chang-Gyun An
BCBong-Yeon Choi
Bong-Yeon Choi
HLHoon Lee
Hoon Lee
TKTae-Gyu Kim
Tae-Gyu Kim
KKKyung-Min Kang
Kyung-Min Kang
CWChung-Yuen Won
Chung-Yuen Won
In this paper, we propose a novel switching modulation scheme for three-phase four-leg inverters that enables the separation of the fault points occurring in AC distribution networks. The proposed method is aimed at continuously supplying normal voltage to the remaining healthy phases while applying zero voltage to any faulty phase when a single line-to-ground (SLG) fault occurs in the distribution network. This modulation scheme allows isolation without physically blocking the point of failure. This can prevent unnecessary continuous outages in the AC distribution network. To this end, we propose a novel coordinate transformation method to extract accurate values for the magnitude of unbalanced three-phase voltages. A novel space vector pulse-width modulation (SVPWM) method for switching schemes that are used under fault conditions is also presented. The proposed coordinate transformation considers a plane lying in a three-dimensional (3-D) space that describes the rotation of a three-phase voltage vector. This transformation converts a physical quantity that rotates in 3-D space into a value that moves in two-dimensional (2-D) space. Subsequently, the use of synchronous reference frame (SRF) transformation enables the detection and control of the voltage magnitude in case of an SLG fault. Additionally, switching vectors are selected to apply zero voltage to the faulty phase by analyzing the switching vector diagram of a four-leg inverter. Mathematical analyses conducted for the entire process are detailed herein. Further, the experimental results of four-leg inverters designed for the 10 kW class verify the proposed strategies.

31 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
WJWon-Sang Jeong
Won-Sang Jeong
YLYoon-Seong Lee
Yoon-Seong Lee
JLJung-Hyo Lee
Jung-Hyo Lee
CLChang-Hee Lee
Chang-Hee Lee
CWChung-Yuen Won
Chung-Yuen Won
This paper proposes a space vector modulation (SVM)-based common-mode (CM) currents reduction method of an H8 inverter for permanent magnet synchronous motor (PMSM) drives. There are power quality issues in the PMSM drive systems, such as current distortions and CM electromagnetic interference (EMI) due to the fast-switching operation of the inverter. These issues are related to CM voltage (CMV) and CM current (CMC). Although several studies have been conducted to reduce the CMV and CMC, some CMV variations and CMCs are still generated in the real implementation. Unlike conventional methods, the proposed method selects the voltage vectors with similar CMV levels and arranges them considering the series-connected switch operation of the H8 inverter in a voltage vector modulation sequence. At a low modulation index (MI), the proposed method completely restricts the CMV variations into six times. At high MI, the proposed method synthesizes the reference voltage vector differently, depending on the position of the reference vector, to reduce both current distortions and CMCs. The validity of the proposed method is verified through simulations and experimental results.

13 November 2023 in Energies
Verified
Journal Article
Open access
PDF file
KKKang Kyungmin
Kang Kyungmin
YKYoung-Sang Ko
Young-Sang Ko
YLYoon-Seong Lee
Yoon-Seong Lee
JYJunsin Yi
Junsin Yi
CWChung-Yuen Won
Chung-Yuen Won
This paper proposes a hybrid power supply system for commercial drones. The proposed hybrid power supply system consists of a lithium polymer battery, a supercapacitor, and a power converter for charging the supercapacitor. In the proposed system, the supercapacitor is pre-charged with a lithium polymer battery through a power converter, and the supercapacitor first supplies the power required for the drone’s initial startup and lift-up. Afterward, in the section where the power consumption of the drone is low, the battery and the supercapacitor supply power together, minimizing the stress on the battery. To verify the proposed hybrid power supply system, a computer simulation was conducted, the actual hardware was fabricated, and experiments were performed.

20 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
YLYoon-Seong Lee
Yoon-Seong Lee
KCKyoung-Min Choo
Kyoung-Min Choo
WJWon-Sang Jeong
Won-Sang Jeong
CLChang-Hee Lee
Chang-Hee Lee
JYJunsin Yi
Junsin Yi
CWChung-Yuen Won
Chung-Yuen Won
A virtual impedance-based flying start considering transient characteristics for permanent magnet synchronous machine drive systems is proposed. The conventional flying start based on virtual resistance (VR) assumes that the load of the system is resistive. However, the maximum value of VR, which is determined by the machine parameter and sampling frequency, is sometimes small. In this case, the load of the system is non-resistive. This assumption error causes an estimated position error and degrades transient characteristics. In the proposed method, algebraic-type virtual inductance (VI) is added to the estimation current regulator of the flying start based on VR. This change improves the accuracy of the estimated rotor position and the transient characteristics. In addition, the discrete-time system model of the proposed flying start method is given, the stability was analyzed considering the change in VR caused by the proposed method, and the improvements were verified by PSIM simulations and experimental results.