Objectives: To assess the behavior of dual-cure and conventional bulk-fill composite materials on real-time linear shrinkage, shrinkage stress, and degree of conversion. Materials and methods: Two dual-cure bulk-fill materials (Cention, Ivoclar Vivadent (with ion-releasing properties) and Fill-Up!, Coltene) and two conventional bulk-fill composites (Tetric PowerFill, Ivoclar Vivadent; SDR flow + , Dentsply Sirona) were compared to conventional reference materials (Ceram.x Spectra ST (HV), Dentsply Sirona; X-flow; Dentsply Sirona). Light curing was performed for 20 s, or specimens were left to self-cure only. Linear shrinkage, shrinkage stress, and degree of conversion were measured in real time for 4 h (n = 8 per group), and kinetic parameters were determined for shrinkage stress and degree of conversion. Data were statistically analyzed by ANOVA followed by post hoc tests (α = 0.05). Pearson’s analysis was used for correlating linear shrinkage and shrinkage force. Results: Significantly higher linear shrinkage and shrinkage stress were found for the low-viscosity materials compared to the high-viscosity materials. No significant difference in degree of conversion was revealed between the polymerization modes of the dual-cure bulk-fill composite Fill-Up!, but the time to achieve maximum polymerization rate was significantly longer for the self-cure mode. Significant differences in degree of conversion were however found between the polymerization modes of the ion-releasing bulk-fill material Cention, which also exhibited the significantly slowest polymerization rate of all materials when chemically cured. Conclusions: While some of the parameters tested were found to be consistent across all materials studied, heterogeneity increased for others. Clinical relevance: With the introduction of new classes of composite materials, predicting the effects of individual parameters on final clinically relevant properties becomes more difficult.
This study investigated the effect of over-etching and prolonged application time of a universal adhesive on dentin bond strength. Ninety extracted human molars were ground to dentin and randomly allocated into nine groups (G1–9; n = 10 per group), according to the following acid etching and adhesive application times. In the control group (G1), phosphoric acid etching was performed for 15 s followed by application of the universal adhesive Scotchbond Universal (3M) for 20 s, as per manufacturer’s instructions. In groups G2–5, both the etching and adhesive application times were either halved, doubled, quadrupled, or increased eightfold. In groups G6–9, etching times remained the same as in G2–5 (7.5 s, 30 s, 60 s, and 120 s, respectively), but the adhesive application time was set at 20 s as in the control group (G1). Specimens were then restored with a nanofilled composite material and subjected to microtensile bond strength testing. Bond strength data were statistically analyzed by ANOVA and Tukey’s post-hoc tests (α = 0.05). The relationship of bond strength with etching and adhesive application time was examined using linear regression analysis. Treatment of dentin with halved phosphoric acid etching and adhesive application times (G2) resulted in a significant bond strength decrease compared to the control group (G1) and all other test groups, including the group with halved acid etching, but 20 s of adhesive application time (G6). No significant differences in bond strength were found for groups with multiplied etching times and an adhesive application time of 20 s or more, when compared to the control group (G1). In conclusion, a universal adhesive application time of at least 20 s is recommended when bonding to over-etched dentin.
This study investigated polymerization kinetics, linear shrinkage, and shrinkage stress development for six contemporary composite materials of different viscosities cured using radiant exitances of 1100–2850 mW/cm2. Real-time measurements of degree of conversion, linear shrinkage, and shrinkage stress were performed over 5 min using Fourier-transform infrared spectrometry, a custom-made linometer, and a custom-made stress analyzer, respectively. For most tested variables, the factor “material” had a higher effect size than the factor “curing protocol”. Maximum polymerization rate and maximum shrinkage stress rate were the most affected by changes in curing conditions. In contrast, no significant effects of curing conditions were identified within each material for shrinkage stress values measured at the end of the 5 min observation period. Linear shrinkage and shrinkage stress values measured after 5 min were closely correlated (R = 0.905–0.982). The analysis of polymerization kinetics suggested that the two composites specifically designed for rapid light-curing responded to higher radiant exitances differently than other composites. Polymerization kinetics and shrinkage stress behavior of contemporary restorative composite materials of different viscosities were overall more affected by material type than differences in curing conditions. Subtle differences in polymerization kinetics behavior shown by the two composites specifically designed for rapid high-intensity light-curing did not translate into significant differences in the development of polymerization shrinkage stress.
This study investigates the effect of defined working distances between the tip of a sandblasting device and a resin composite surface on the composite–composite repair bond strength. Resin composite specimens (Ceram.x Spectra ST (HV); Dentsply Sirona, Konstanz, Germany) were aged by thermal cycling (5000 cycles, 5–55 °C) and one week of water storage. Mechanical surface conditioning of the substrate surfaces was performed by sandblasting with aluminum oxide particles (50 µm, 3 bar, 10 s) from varying working distances of 1, 5, 10, and 15 mm. Specimens were then silanized and restored by application of an adhesive system and repair composite material (Ceram.x Spectra ST (HV)). In the negative control group, no mechanical surface pretreatment or silanization was performed. Directly applied inherent increments served as the positive control group (n = 8). After thermal cycling of all groups, microtensile repair bond strength was assessed, and surfaces were additionally characterized using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). The negative control group reached the significantly lowest microtensile bond strength of all groups. No significant differences in repair bond strength were observed within the groups with varying sandblasting distances. Composite surfaces sandblasted from a distance of 1 mm or 5 mm showed no difference in repair bond strength compared to the positive control group, whereas distances of 10 or 15 mm revealed significantly higher repair bond strengths than the inherent incremental bond strength (positive control group). In conclusion, all sandblasted test groups achieved similar or higher repair bond strength than the inherent incremental bond strength, indicating that irrespective of the employed working distance between the sandblasting device and the composite substrate surface, repair restorations can be successfully performed.
Enzymes in toothpastes can support host immune responses, and thus maintain oral health. This study aimed to investigate gingival health and the plaque-reducing effects of enzyme-containing toothpastes. A laboratory study tested the antimicrobial potential of different enzyme-containing toothpaste formulations. Two promising formulations (enzyme-containing toothpastes with glucose oxidase and D-glucose with (C+) and without Citrox (C−) Citrox) were investigated in a clinical crossover trial (two slurries: sodium lauryl sulfate-containing (SLS), a toothpaste without SLS (reference), and water). Subjects (n = 20) abstained from toothbrushing for four days and rinsed with a toothpaste slurry. Bleeding on probing (BOP) and plaque indices (PI) were measured. A mixed linear model was used to statistically compare the slurries with respect to BOP and PI change. The in vitro bacterial growth-inhibiting evaluation showed the best results for SLS, followed by C+ and C−. The change in BOP and PI exhibited statistically significant differences to water rinsing (BOP; PI changes in % points (difference of the baseline and post-rinse values: water = 8.8%; 90.0%; C+ = −1.4%; 80.4%; SLS = 1.5%; 72.1%; reference = 0.8%; 77.5%; C− = −1.8%; 75.1%). All slurries exhibited anti-gingivitis and anti-plaque effects, resulting in a prophylactic benefit for limited-access regions during brushing.
We embedded copper-doped mesoporous bioactive glass nanospheres (Cu-MBGN) with antibacterial and ion-releasing properties into experimental dental composites and investigated the effect of Cu-MBGN on the polymerisation properties. We prepared seven composites with a BisGMA/TEGDMA (60/40) matrix and 65 wt.% total filler content, added Cu-MBGN or a combination of Cu-MBGN and silanised silica to the silanised barium glass base, and examined nine parameters: light transmittance, degree of conversion (DC), maximum polymerisation rate (Rmax), time to reach Rmax, linear shrinkage, shrinkage stress (PSS), maximum PSS rate, time to reach maximum PSS rate, and depth of cure. Cu-MBGN without silica accelerated polymerisation, reduced light transmission, and had the highest DC (58.8 ± 0.9%) and Rmax (9.8 ± 0.2%/s), but lower shrinkage (3 ± 0.05%) and similar PSS (0.89 ± 0.07 MPa) versus the inert reference (0.83 ± 0.13 MPa). Combined Cu-MBGN and silica slowed the Rmax and achieved a similar DC but resulted in higher shrinkage. However, using a combined 5 wt.% Cu-MBGN and silica, the PSS resembled that of the inert reference. The synergistic action of 5 wt.% Cu-MBGN and silanised silica in combination with silanised barium glass resulted in a material with the highest likelihood for dental applications in future.