Di Liu

Di Liu

Auto-generated profile, based on publicly available information

Di Liu

Department of Electronic and Electrical Engineering University of Strathclyde Glasgow UK

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
DLDi Liu
Di Liu
ADAdam Dysko
Adam Dysko
QHQiteng Hong
Qiteng Hong
DTDimitrios Tzelepis
Dimitrios Tzelepis
CBCampbell Booth
Campbell Booth
When faults occur in the microgrids, high frequency transients will be superimposed on the system currents and voltages. The magnitude of those transients will attenuate as it encounters the discontinuity points in the network such as busbars, or any other impedance discontinuity points. This phenomenon can also be quantified by wavelet energy, which provides a useful tool to detect faults and locate the faulted feeder in the microgrid. In this paper, a novel protection scheme based on the transient wavelet energy of the superimposed current extracted by the Maximal Overlap Discrete Wavelet Transform (MODWT) algorithm is developed to detect faults and locate the faulted feeder in microgrids. Compared with existing protection schemes, the proposed protection scheme has the advantage of being largely immune to the changes in system fault level, fault types and positions, microgrid operating status and the control strategies deployed on the inverters, while presenting much lower requirement on the sampling frequency (10 kHz) compared with travelling wave-based methods. Unlike the conventional differential protection, the proposed scheme does not require synchronized measurement or high bandwidth communication channels, and thus, it can be considered as an economical and promising solution for microgrids.

20 July 2024 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
LLLingxia Li
Lingxia Li
WZWenbo Zhang
Wenbo Zhang
JZJiayin Zhang
Jiayin Zhang
DLDi Liu
Di Liu
LJLi Junchen
Li Junchen
XLXuefeng Lu
Xuefeng Lu

10 April 2024 in Journal of Energy Storage
Verified
Journal Article
Closed access
LLLingxia Li
Lingxia Li
WZWenbo Zhang
Wenbo Zhang
JZJiayin Zhang
Jiayin Zhang
DLDi Liu
Di Liu
JRJunqiang Ren
Junqiang Ren
XLXuefeng Lu
Xuefeng Lu

1 January 2012
Verified
Conference Paper
Closed access
WSWang Shuo
Wang Shuo
XXXiao Xiangning
Xiao Xiangning
XYXu Yonghai
Xu Yonghai
ZJZheng Jianhui
Zheng Jianhui
STShun Tao
Shun Tao
LYLin Yan
Lin Yan

11 October 2024 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
CLChengwei Liu
Chengwei Liu
JRJoan Marc Rodriguez‐Bernuz
Joan Marc Rodriguez‐Bernuz
DLDi Liu
Di Liu
SYSaizhao Yang
Saizhao Yang
YLYitong Li
Yitong Li
AJAdrià Junyent‐Ferré
Adrià Junyent‐Ferré
Low voltage DC (LVDC) microgrids (MGs) can be linked together through an interconnection network to enhance the utilization of their energy resources in remote locations, particularly in rural low‐income areas. However, the identification of the fault is challenging due to the fast fault transients and equipment limitations, where there are no sensors and DC circuit breakers (DCCBs) in the lines. To solve this problem, this article proposes a fault detection and location algorithm without requiring extra sensors and DCCBs in lines. The proposed algorithm uses the sensors of the interface converters to detect the fault. Following this, a coordinated current injection method is used to identify the faulty element by coordinating converters with disconnectors. This process employs two strategies “weight check” and “scope check” to minimize the time and the number of actions. The algorithm is robust to various fault impedance, fault types and network topology modifications. The effectiveness of the algorithm is validated through a series of simulation case studies.

15 June 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
PRPannita Rajakrom
Pannita Rajakrom
CBCampbell Booth
Campbell Booth
DLDi Liu
Di Liu
QHQiteng Hong
Qiteng Hong
The increasing penetration of Renewable Energy Resources (RESs) across the distribution network is fundamentally reshaping the fault behaviour of power networks. Variable fault levels and bidirectional power flow become more prevalent, which present significant challenges for conventional protection systems and increase the risk of maloperation or protection failure. To address these issues, this paper presents a current measurement-based protection algorithm for identifying the faulted section in active distribution networks with high penetrations of Distributed Energy Resources (DERs). The proposed scheme compares and analyses pre-fault and during-fault current data to locate the faulted section within the network. In contrast to conventional differential protection, which requires the continuous exchange of three‐phase current measurements between local and remote terminals, the proposed scheme transmits only compact binary-coded information during fault events, thereby substantially reducing communication requirements while maintaining high reliability. The performance of the proposed scheme is comprehensively validated under a wide range of system operation and fault conditions with both simulation-based and Real-Time-Digital-Simulator (RTDS)-based Hardware-in-the-Loop (HIL) tests. Results from both tests demonstrate that the proposed algorithm consistently delivers high performance, security, and reliability, while reducing the complexity of algorithm and simplifying data handling.