Valentin Craciun

Dr. Valentin Craciun

(1) Laser Department, National Institute for Laser, Plasma, and Radiation Physics, 77125 Mǎgurele, Romania
+1

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Irimiciuc Stefan-AndreiIrimiciuc Stefan-Andrei
Irimiciuc Stefan-Andrei
SCSergii Chertopalov
Sergii Chertopalov
Jan LancokJan Lancok
Jan Lancok
VCValentin Craciun
Valentin Craciun
The history of pulsed laser deposition (PLD) and transient plasmas generated by laser ablation is intertwined with the development of various techniques for its fundamental understanding. Some diagnostic tools have been developed to better suit the rapid transient nature of the plasma (space and time dependence of all parameters, fast decay and complex chemistry inside the plasma), whereas others have been adapted from basic plasma physics studies. Langmuir probe method has been used as a real-time in situ diagnostic tool for laser ablation and later for PLD. It remains a useful tool for the PLD community arsenal, which can easily be adapted to the development of new lasers and ablation regimes and new deposition configuration, being one of the most versatile techniques for plasma diagnostics. It is the cornerstone on which charge particles are analyzed and has led to several important discoveries, such as multiple peak distribution, selective acceleration during expansion, plume splitting, plasma turbulences and fluctuations. However, because the Langmuir probe theory adaptation from classical plasma physics is not straightforward, it might lead to misinterpretation and often incorrect analysis of data. This review analyzes the limits and understanding of the technique as a foundation for attaining its full potential, which can impact the way PLD is used. This is especially useful for the pressing need of real-time, in-situ diagnostics and feedback loops for systematic semi-industrial implementation of the PLD technique.

20 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
GCGeorge Constantin
George Constantin
EBEmilia Balan
Emilia Balan
Ionelia VoiculescuIonelia Voiculescu
Ionelia Voiculescu
VGVictor Geantă
Victor Geantă
VCValentin Craciun
Valentin Craciun
There is an increased interest in high entropy alloys as a result of the special possibilities of improving the mechanical, physical or chemical characteristics resulting from metallic matrices made of different chemical elements added in equimolar proportions. The next step in developing new alloys is to determine the cutting conditions to optimize manufacturing prescriptions. This article presents a series of tests performed to estimate the machining behavior of the Al0.6CoCrFeNi high entropy alloy. The effects of temperature during machining, wear effects on the cutting tool, evolution of the hardness on the processed areas, cutting force components and resultant cutting force for high entropy alloy (HEA) in comparison with 304 stainless steel, scrap aspect and machined surface quality were analyzed to have an image of the HEA machinability. In terms of cutting forces, the behavior of the HEA was found to be about 59% better than that of stainless steel. XRD analysis demonstrated that the patterns are very similar for as-cast and machined surfaces. The wear effects that appear on the cutting edge faces for the tool made of rapid steel compared to carbide during HEA machining led to the conclusion that physical vapor deposition (PVD)-coated carbide inserts are suitable for the cutting of HEAs.

20 April 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
GDGabriela Dorcioman
Gabriela Dorcioman
VGValentina Grumezescu
Valentina Grumezescu
George StanGeorge Stan
George Stan
Carmen ChifiriucCarmen Chifiriuc
Carmen Chifiriuc
Gratiela GRADISTEANU PircalabioruGratiela GRADISTEANU Pircalabioru
Gratiela GRADISTEANU Pircalabioru
Liviu DutaLiviu Duta
Liviu Duta
Novel biomaterials with promising bone regeneration potential, derived from rich, renewable, and cheap sources, are reported. Thus, thin films were synthesized from marine-derived (i.e., from fish bones and seashells) hydroxyapatite (MdHA) by pulsed laser deposition (PLD) technique. Besides the physical–chemical and mechanical investigations, the deposited thin films were also evaluated in vitro using dedicated cytocompatibility and antimicrobial assays. The morphological examination of MdHA films revealed the fabrication of rough surfaces, which were shown to favor good cell adhesion, and furthermore could foster the in-situ anchorage of implants. The strong hydrophilic behavior of the thin films was evidenced by contact angle (CA) measurements, with values in the range of 15–18°. The inferred bonding strength adherence values were superior (i.e., ~49 MPa) to the threshold established by ISO regulation for high-load implant coatings. After immersion in biological fluids, the growth of an apatite-based layer was noted, which indicated the good mineralization capacity of the MdHA films. All PLD films exhibited low cytotoxicity on osteoblast, fibroblast, and epithelial cells. Moreover, a persistent protective effect against bacterial and fungal colonization (i.e., 1- to 3-log reduction of E. coli, E. faecalis, and C. albicans growth) was demonstrated after 48 h of incubation, with respect to the Ti control. The good cytocompatibility and effective antimicrobial activity, along with the reduced fabrication costs from sustainable sources (available in large quantities), should, therefore, recommend the MdHA materials proposed herein as innovative and viable solutions for the development of novel coatings for metallic dental implants.

5 June 2015 in Materials
Verified
Journal Article
Open access
PDF file
Andrei PopescuAndrei Popescu
Andrei Popescu
George StanGeorge Stan
George Stan
Liviu DutaLiviu Duta
Liviu Duta
CNCristina Nita
Cristina Nita
EPElena Camelia Popescu
Elena Camelia Popescu
VCValentin Craciun
Valentin Craciun
Hard carbon thin films were synthesized on Si (100) and quartz substrates by the Pulsed Laser Deposition (PLD) technique in vacuum or methane ambient to study their suitability for applications requiring high mechanical resistance. The deposited films’ surface morphology was investigated by scanning electron microscopy, crystalline status by X-ray diffraction, packing and density by X-ray reflectivity, chemical bonding by Raman and X-ray photoelectron spectroscopy, adherence by “pull-out” measurements and mechanical properties by nanoindentation tests. Films synthesized in vacuum were a-C DLC type, while films synthesized in methane were categorized as a-C:H. The majority of PLD films consisted of two layers: one low density layer towards the surface and a higher density layer in contact with the substrate. The deposition gas pressure played a crucial role on films thickness, component layers thickness ratio, structure and mechanical properties. The films were smooth, amorphous and composed of a mixture of sp3-sp2 carbon, with sp3 content ranging between 50% and 90%. The thickness and density of the two constituent layers of a film directly determined its mechanical properties.

27 December 2022 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
JLJian-Sian Li
Jian-Sian Li
XXXinyi Xia
Xinyi Xia
CCChao-Ching Chiang
Chao-Ching Chiang
DHDavid C. Hays
David C. Hays
BGBrent P. Gila
Brent P. Gila
SPStephen Pearton
Stephen Pearton
The characteristics of sputtered NiO for use in pn heterojunctions with Ga2O3 were investigated as a function of sputtering parameters and postdeposition annealing temperature. The oxygen/ nickel and Ni2O3/NiO ratios, as well as the bandgap and resistivity, increased as a function of O2/Ar gas flow ratio. For example, the bandgap increased from 3.7 to 3.9 eV and the resistivity increased from 0.1 to 2.9 Ω cm for the O2/Ar ratio increasing from 1/30 to 1/3. By sharp contrast, the bandgap and Ni2O3/NiO ratio decreased monotonically with postdeposition annealing temperatures up to 600 °C, but the density of films increased due to a higher fraction of NiO being present. Hydrogen is readily incorporated into NiO during exposure to plasmas, as delineated by secondary ion mass spectrometry measurements on deuterated films. The band alignments of NiO films were type II-staggered gaps with both α- and β-Ga2O3. The breakdown voltage of NiO/β-Ga2O3 heterojunction rectifiers was also a strong function of the O2/Ar flow ratio during deposition, with values of 1350 V for 1/3 and 830 V for 1/30.

25 July 2019 in Beilstein Journal of Nanotechnology
Verified
Journal Article
Open access
PDF file
Petronela GaroiPetronela Garoi
Petronela Garoi
Ionel StavaracheIonel Stavarache
Ionel Stavarache
DCDoina Craciun
Doina Craciun
FGFlorin Garoi
Florin Garoi
CNConstantin-Catalin Negrila
Constantin-Catalin Negrila
VCValentin Craciun
Valentin Craciun
Rapid thermal annealing for high-quality ITO thin films deposited by radio-frequency magnetron sputtering