In the frame of the Next Generation Europe program, the EU program to boost after-COVID recovery, the Italian Minister of University and Research has funded a project called Innovative Research Infrastructure for applied Superconductivity (IRIS). New laboratories will be built or upgraded in six poles: Milan (hub of the infrastructure), Genoa, Frascati, Naples, Salerno, and Lecce, to carry out basic research on magnetism and superconducting materials, test of wires, tapes, and large current cables, superconducting magnets construction with advanced instrumentation, power tests of magnets, and a special facility for high current-high voltage superconducting lines. The program will be executed over three years and then will operate for at least 10 years. It includes two first demonstrators: one HTS magnet to be operated at 10–20 K and a superconducting line of 1 GW (40 kA–25 kV) about 140 m long. The demonstrators anticipate the main scope of the investment in the IRIS infrastructure: to support the use of superconductivity for improving sustainability by decreasing the energy consumption without compromising performance. This article describes the global IRIS project.
Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.
The CompactLight European consortium is designing a state-of-the-art X-ray free-electron laser driven by radiofrequency X-band technology. Rooted in experimental data on photo-injector performance in the recent literature, this study estimates analytically and numerically the performance of the CompactLight delivery system for bunch charges in the range 75–300 pC. Space-charge forces in the injector, linac transverse wakefield, and coherent synchrotron radiation in bunch compressors are all taken into account. The study confirms efficient lasing in the soft X-rays regime with pulse energies up to hundreds of microjoules at repetition rates as high as 1 kHz.
12 January 2024 in IEEE Transactions on Applied Superconductivity
In the framework of the euro SIG project and within an international collaboration between CNAO, CERN, INFN, and MedAustron, the design of a novel gantry for hadron therapy based on superconducting magnets and a downstream scanning system has been undertaken. The choice of placing the scanning system downstream of the last superconducting dipole plays a crucial role in the overall layout of the gantry, having a direct impact on its radius, weight, and cost. The proposed design for the scanning system considers two separate normal-conducting scanning magnets with a central field in the order of 1 T, three times higher than the current state-of-the-art scanning magnets for hadron therapy. Such a magnetic field value for a fast-pulsed magnet poses interesting questions regarding non-linearities due to the yoke saturation, hysteretic effects, and eddy currents. In this context, it is important to develop reliable models to study the behavior of the magnet at various levels of current and magnetic field. For this reason, we implemented two and three-dimensional simulations of a short dipole with FeCo yoke and we validated them against experimental measurements. In this paper, we focus on the modelization of the hysteretic behavior of this magnet, providing insight into the feasibility of proposed scanning magnets.
1 July 2020 in Journal of Physics: Conference Series
Applications such as colliders and plasma wake field acceleration require high gradient quadrupoles, in the range of 400-500 T/m and with a bore of few millimeters in diameter. The design of a tunable high gradient permanent magnet quadrupole (PMQ), based on the QUAPEVA design [1] developed for the SOLEIL synchrotron, is presented. The quadrupole has a fixed part made of a Halbach quadrupole array [3, 4] surrounded by four permanent magnet cylinders with a radial orientation of the magnetic momentum. The gradient is regulated by rotating the cylinders, reaching a tunability greater than the 25%. The quadrupole has been designed for the COMB plasma wake field beam driven experiment for the SPARC_LAB test-facility at INFN-LNF [2], one of the candidates to host the EuPRAXIA project [7, 8]. The present layout foresees two triplets where the focusing strength tuning is performed by moving two quadrupoles of each triplet along the beam axis. The new quadrupoles have bigger gradient and less multipolar content than actual ones, moreover it has a tuning system that does not need any shift of the magnet.
19 May 2026 in Physical Review Accelerators and Beams
The SPARC_LAB facility, operating at the LNF-INFN laboratories in Frascati, has been devoted over the past years to R&D related to accelerators, advanced diagnostics, and generation of radiation ranging from THz to extreme UV light. The facility has recently been significantly upgraded and moved toward user-oriented applications, especially after the approval of two additional projects with the goal to develop radiation sources up to the soft x-ray range and in view of the EuPRAXIA project, whose preparatory phase is ongoing with the support of the European Commission. This paper summarizes the electron beam and radiation parameters and describes the layout and main features of the upgraded facility in view of future user-oriented experimental activities and applications.
About Me
PhD in accelerator Physics. Magnet designer and power supply expert
PhD in accelerator Physics. Magnet designer and power supply expert