Yuan Yao

Dr. Yuan Yao


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
JCJiaxiao Chen
Jiaxiao Chen
QLQianbo Lu
Qianbo Lu
Jian BaiJian Bai
Jian Bai
XXXiang Xu
Xiang Xu
YYYuan Yao
Yuan Yao
WFWeidong Fang
Weidong Fang
External temperature changes can detrimentally affect the properties of a microaccelerometer, especially for high-precision accelerometers. Temperature control is the fundamental method to reduce the thermal effect on microaccelerometer chips, although high-performance control has remained elusive using the conventional proportional-integral-derivative (PID) control method. This paper proposes a modified approach based on a genetic algorithm and fuzzy PID, which yields a profound improvement compared with the typical PID method. A sandwiched microaccelerometer chip with a measurement resistor and a heating resistor on the substrate serves as the hardware object, and the transfer function is identified by a self-built measurement system. The initial parameters of the modified PID are obtained through the genetic algorithm, whereas a fuzzy strategy is implemented to enable real-time adjustment. According to the simulation results, the proposed temperature control method has the advantages of a fast response, short settling time, small overshoot, small steady-state error, and strong robustness. It outperforms the normal PID method and previously reported counterparts. This design method as well as the approach can be of practical use and applied to chip-level package structures.

29 September 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
HTHongyu Tan
Hongyu Tan
DPDebin Pan
Debin Pan
CWChensheng Wang
Chensheng Wang
YYYuan Yao
Yuan Yao
The cavity optomechanical accelerometer based on photonic crystal microcavities combines mechanical resonators with high-quality factor photonic crystal cavities. The mechanical vibrator is sensitive to weak force/displacement in mechanical resonance modes, which can achieve extremely low noise levels and theoretically reach the standard qillatum noise limit. It is an important development direction for high-precision accelerometers. This article analyzes the principle and structural characteristics of a zipper type photonic crystal cavity optomechanical accelerometer, and designs a silicon-based zipper type photonic crystal cavity and mechanical vibrator structure applied to the accelerometer. The influence of the structural parameters of the zipper cavity on the optical Q factor was analyzed in detail. The resonant frequency of the optical cavity was controlled around 195 THz by adjusting the structural parameters, and the mechanical resonance characteristics of the mechanical vibrator and the optical cavity were analyzed. The effective mass of the optical cavity was 30 pg, and, with the addition of the mechanical vibrator, the effective mass was 3.1 ng. The optical mechanical coupling rate reached the GHz/nm level, providing guidance for the manufacturing and characterization of silicon-based zipper cavity accelerometers.

10 October 2024 in Research Square
Verified
Preprint
Open access
PDF file
HUAFENG LIUHUAFENG LIU
HUAFENG LIU
CWChen Wang
Chen Wang
YYYuan Yao
Yuan Yao
MSMilad Shojaeian
Milad Shojaeian
SSSina Sadeghpour
Sina Sadeghpour
PMPui-In Mak
Pui-In Mak
This paper presents a MEMS accelerometer featuring an auto-tuning system based on an electrostatic anti-spring mechanism. The accelerometer's sensitivity can be automatically adjusted to modify its measurement range and bandwidth in response to varying acceleration inputs. Comprehensive theoretical analysis and experimental validation were performed, demonstrating strong agreement between experimental results and theoretical predictions. As the acceleration input increased, the sensitivity of the MEMS accelerometer with the auto-tuning system increased, while its bandwidth decreased. Furthermore, this new design exhibited significantly higher sensitivity for a given acceleration input compared to the conventional design. Specifically, the sensitivity of the new design at 15.4 V actuation voltage was measured at 39.43 V/g at 0 g acceleration, which is 30.80 times greater than that of the conventional design (1.28 V/g). The spring constant was reduced from its original mechanical value of 41.0 N/m to 1.38 N/m at 0 g acceleration. Additionally, the noise floor and dynamic range of the new design are 279 ng/ √Hz at 100 Hz (30.9 times higher than that of the conventional design) and 157 dB (30 dB higher than that of the conventional design), respectively.