Olesya Kytko

Prof. Olesya Kytko


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
KZKirill Zhandarov
Kirill Zhandarov
EBEkaterina Blinova
Ekaterina Blinova
EOEgor Ogarev
Egor Ogarev
DSDmitry Sheptulin
Dmitry Sheptulin
ETElizaveta Terekhina
Elizaveta Terekhina
YEYulianna Enina
Yulianna Enina
This study addresses the cervical part of the vertebral column. Clinical pictures of dystrophic diseases of the cervical part of the vertebral column do not always correspond only to the morphological changes—they may be represented by connective tissue formation and nerve and vessel compression. To find out the possible reason, this morphometric study of the cervical part of the vertebral column in 40 cadavers was performed. CT scans were performed on 17 cadaveric material specimens. A total of 12 histological samples of connective tissue structures located in intervertebral canals (IC) were studied. One such formation, an intracanal ligament (IL) located in the IC, was found. Today, there is no term “intervertebral canal”, nor is there a detailed description of the intervertebral canal in the cervical part of the vertebral column. Cervical intervertebral canals make up five pairs in segments C2–C7. On cadavers, the IC lateral and medial apertures were 0.9–1.5 cm and 0.5–0.9 cm, correspondingly. According to our histological study, the connective tissue structures in the IC are ligaments—IL. According to the presence of these ligaments, ICs were classified into three types. Complete regional anatomy characterization of the IC of the cervical part of the vertebral column with a description of its constituent anatomical elements was provided. The findings demonstrate the need to include the terms “intervertebral canal” and “intervertebral ligament” in the Terminologia anatomica.

4 October 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
OKOlesya Kytko
Olesya Kytko
YVYuriy Vasil'ev
Yuriy Vasil'ev
EEEkaterina Emelyanova
Ekaterina Emelyanova
EKEvgeniy Kutin
Evgeniy Kutin
RSRamin Sarmadian
Ramin Sarmadian
RERebrova Ekaterina
Rebrova Ekaterina
Objective: The objective of this study was to clarify the connection between BTX-A injections and local changes in skin temperature and to assess the correlation between post-BTX-A injection facial vascular hyperthermia and subcutaneous adipose tissue thickness (SAT) in the frontal area using thermography. Methods: The study involved 30 patients (mean age 42 ± 0.5 years; 18 women, 12 men). Facial skin temperature was measured via thermography (Thermo GEAR G30) before, immediately after, and 20 min after subcutaneous injection of BTX-A with hemagglutinin complex, gelatin (6 mg), and maltose monohydrate (12 mg). SAT development was graded by combined visual-palpation assessment. Statistical analysis included Student’s t-test and the Mann–Whitney U-test. Results: Biphasic thermal response: immediately post-injection: Significant decrease in min (−1.1 °C) and mean (−0.3 °C) facial temperatures (p < 0.05); 20 min post-injection: pronounced increase in mean (+1.5 °C), max (+1.3 °C), and min (+1.6 °C) temperatures (p < 0.001), attributed to BTX-A-induced vasodilation and local inflammation. Subjects with pronounced SAT exhibited significantly higher baseline temperatures (Me = 33.1 °C vs. 29.8 °C; p < 0.001) and more intense hyperthermic responses (+1.6 °C mean increase vs. +1.1 °C in low-SAT group; p < 0.001). Pronounced SAT was predominantly female (10/15; p < 0.05) and linked to higher BMI (33.3% overweight vs. 0% in low-SAT; *p = 0.036*). Conclusions: SAT thickness is a key determinant of post-BTX-A vascular hyperthermia, with pronounced SAT predicting stronger reactions. Practical Recommendation: Targeted local hypothermia (+4 °C to +8 °C for 5–7 min post-injection, adjustable by SAT thickness) mitigates hyperemia, edema, hematoma risk, and potential toxin diffusion, especially in high-SAT individuals.

17 March 2025 in Life
Verified
Journal Article
Open access
PDF file
Ekaterina DiachkovaEkaterina Diachkova
Ekaterina Diachkova
STSvetlana Tarasenko
Svetlana Tarasenko
MSMarina Skachkova
Marina Skachkova
YZYury Zhilkov
Yury Zhilkov
NSNatalia Serova
Natalia Serova
OKOlesya Kytko
Olesya Kytko
(1) Background: A decrease in bone mineral density has been noted not only in at-risk patients (e.g., postmenopausal women) but also in young and middle-aged individuals due to changes in lifestyle. The aim of the study was to find a possible correlation for dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT) with cone beam computed tomography (CBCT) of the jaws. (2) Methods: A total of 24 patients (14 women and 10 men aged 25 to 50 years) with partial secondary tooth loss and vitamin D insufficiency underwent cone beam computed tomography of the jaws and skeletal mineral density assessment using DXA (n = 12) and QCT (n = 12). (3) Results: When conducting CBCT of the jaws, a predominance of bone tissue type D3 (350–850 Hu) on the upper jaw (p > 0.05 (F = 0.68) and D2 (850–1350 Hu) on the lower jaw (p > 0.05 (F = 1) was revealed. According to the results of QCT densitometry of the skeleton, signs of osteopenia were found in four patients (with vitamin D3 deficiency) (33%) according to DXA; signs of osteopenia were found in six patients (with severe deficiency and deficiency of vitamin D3) (50%). The difference between QCT and DXA was not significant (p > 0.05) for each group. The significant strong correlation between CBCT and DXA or QCT was not found (p > 0.05). (4) Conclusions: Primary changes in bone density can be detected earlier in the dental system using cone beam computed tomography of the jaws. At the same time, the question of using a specific densitometry method—DXA or QCT—remains open, as their results correlating with CBCT optical density was not approved.

29 August 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ekaterina DiachkovaEkaterina Diachkova
Ekaterina Diachkova
MSMarina Skachkova
Marina Skachkova
YZYury Zhilkov
Yury Zhilkov
MKMagamed Kerimov
Magamed Kerimov
STSvetlana Tarasenko
Svetlana Tarasenko
SCStefano Corbella
Stefano Corbella
Background: Vitamin D3 is an important factor for bone metabolism, and its deficiency may affect dental implantation results. Materials and methods: 384 patients with a diagnosis of tooth loss and vitamin D deficiency were examined and treated with dental implants. Vitamin D3 supplements were prescribed by the endocrinologist for all patients in the individual dose. The patients were divided into two equal study groups (n = 192) depending on the dental implantation period: Group 1—operation after blood serum vitamin D3 level normalization; group 2—before reaching the reference level of vitamin D3. Follow-up examinations were performed on the day of dental implantation, 7 days later, 1, 3, 6, and 12 months later, and every 1 year after treatment (up to 10 years). Implant stability and peri-implant tissue condition were assessed with clinical and X-ray diagnostics. Patients also visited an endocrinologist 2 months after the start of the treatment, then every 6 months. Results: The target vitamin D3 level (30–60 ng/mL) (p < 0.001) was achieved in all patients after treatment. At the control examinations, peri-implantitis was diagnosed in 10 patients (2.6%). It was detected in the group of patients with severe vitamin D deficiency and vitamin D deficiency—2 (25%) and 8 (3.4%) patients; respectively (p < 0.05). There was no significant difference between groups for risk of complications or bone quality after treatment. Conclusions: Timely screening of vitamin D3 levels and the appropriate treatment by an endocrinologist in young and middle-aged patients allow for achieving 97.4% dental implantation success for a ten-year period.

2 May 2026 in Life
Verified
Journal Article
Open access
PDF file
YVYuriy Vasil'ev
Yuriy Vasil'ev
OKOlesya Kytko
Olesya Kytko
EBElena Bakhrushina
Elena Bakhrushina
ISIrina Smilyk
Irina Smilyk
PSPavel Sarygin
Pavel Sarygin
Dmitry V KalininDmitry V Kalinin
Dmitry V Kalinin
Introduction. The superficial musculoaponeurotic system (SMAS) is fundamental for facial soft tissue support and surgical rejuvenation. Although its morphology in the midface and neck is well characterized, the structure of its cranial extension to the forehead remains a subject of terminological uncertainty. The aim of this study was to conduct a detailed histological and immunohistochemical examination of the forehead supporting structures to characterize their morphology and propose an expanded, region-specific classification of the SMAS. Material and methods. Full-thickness tissue specimens (n = 30) were obtained from five standardized facial regions (parotid, buccal, temporal, frontal, and cervical) from 12 male and 18 female body donors (aged 25–70 years). Specimens were processed for histological analysis using hematoxylin and eosin, van Gieson staining, and Masson’s trichrome. Immunohistochemical staining for S100 protein was used to identify neural structures. Morphometric analysis was performed on digitized sections to quantify interseptal distances and the depth of superficial nerve trunks. Results. The analysis confirmed the established SMAS types (I–V) in the cheek, parotid gland, and neck, confirming the validity of the method. Two distinct, sequentially arranged structures were identified on the forehead, proposed as new types. Type VI (neurovascular arborization) is a discrete fan-shaped structures with a central collagen core surrounding a neurovascular bundle, showing positive S100 staining. These structures, spaced approximately 2.2 mm apart, function as true retaining ligaments. Type VII (fibroseptal) SMAS patterns is vertically oriented, purely fibrous septa (retinacula cutis) connecting the aponeurosis to the dermis, devoid of neural elements, and spaced approximately 9.2 mm apart. Importantly, the superficial nerve trunks were located at an average depth of only 1.09 mm (range: 0.57–1.97 mm) from the skin surface. Conclusion. This study identified two novel SMAS patterns in the forehead—neurovascular arborization (type VI) and fibroseptal (type VII)—supporting the expanded functional seven-type classification of the SMAS. The extremely superficial location of the forehead nerves (average 1.1 mm) defines a critical “danger zone” for aesthetic procedures. These findings provide a refined anatomical basis for improving the precision and safety of both surgical and minimally invasive facial procedures.

19 April 2026 in Actual problems in dentistry
Verified
Journal Article
Open access
PDF file
IVIgor Volokhov
Igor Volokhov
DNDmitriy Nosovickiy
Dmitriy Nosovickiy
OKOlesya Kytko
Olesya Kytko
AHArtur Heigetyan
Artur Heigetyan
YVYuri Vasiliev
Yuri Vasiliev
MKMikhail Kushlinov
Mikhail Kushlinov
Background. The elderly population represents a distinct patient category with a high prevalence of dental and somatic diseases. Pharmacotherapy for comorbid conditions in elderly patients increases the risk of adverse effects and complications in dental practice. Stress and fear associated with pain and the injection procedure itself can provoke tachycardia, elevated blood pressure, and lead to refusal of necessary treatment. Recent scientific reviews and statistics demonstrate a significant reduction in injection pain with computer-controlled delivery of local anesthetic compared to the traditional technique. However, the number of studies on the application of this technology in elderly and senile patients, with comprehensive assessment of hemodynamic parameters, stress levels, and anesthesia efficacy and safety, remains limited. Objective. To evaluate the efficacy and safety of a 4 % articaine-containing local anesthetic with a 1:200,000 vasoconstrictor administered via computer-controlled delivery for the treatment of dental diseases in the retromolar area in elderly patients. Materials and Methods. A prospective comparative randomized controlled study was conducted at the dental clinic of Fivestarsdent LLC (Moscow). Patients were randomly allocated into two groups: the first group received anesthesia using a traditional cartridge syringe, the second group using a “Injecta” computer-controlled syringe. The efficacy and safety of anesthesia were assessed based on adverse reactions and complications following mandibular anesthesia with "Articaine INIBSA." Results. The obtained results demonstrate significant advantages of the computer-controlled method for local anesthetic delivery in elderly patients compared to the traditional technique and are consistent with contemporary scientific literature data. Conclusion. The computer-controlled delivery method of 4 % articaine local anesthetic 1:200000 using computer-assisted anesthetic delivery system “Injecta” can be recommended as the method of choice for local anesthesia in elderly and senile patients during dental treatment.