Juozas Ramanauskas

Mr. Juozas Ramanauskas

Kaunas University of Technology

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2015 in Sustainability
Verified
Journal Article
Open access
PDF file
JŠJolanta Šadauskienė
Jolanta Šadauskienė
JRJuozas Ramanauskas
Juozas Ramanauskas
Lina SeduikyteLina Seduikyte
Lina Seduikyte
Mindaugas DaukšysMindaugas Daukšys
Mindaugas Daukšys
AVAlgimantas Vasylius
Algimantas Vasylius
In the design of high-energy performance buildings with ventilated facade systems, the evaluation of point thermal bridges is complicated and is often ignored in practice. This paper analyzes the relationship between the point thermal bridges resulting from aluminum fasteners, which are used for installation facades cladding, and the thermal properties of materials that are used in external walls layers and dimension of layers. Research has shown that the influence of the point thermal bridges on the U-value of the entire wall may achieve an average of up to 30% regarding thermal properties of materials of the external wall layers and the dimension of layers. With the increase in thermal conductivity of the bearing layer material and the thickness of the thermal insulation layer, the point thermal transmittance χ-value increased. For this reason, the U-value of the entire wall may increase by up to 35%. With the increase of the thickness of the bearing layer and thermal conductivity value of thermal insulation layer, the point thermal transmittance χ-value decreased by up to 28%. A simplified methodology is presented for the evaluation of point thermal bridges based on the thermal and geometrical properties of external wall layers.

18 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
Karolis BanionisKarolis Banionis
Karolis Banionis
JKJurga Kumžienė
Jurga Kumžienė
ABArūnas Burlingis
Arūnas Burlingis
JRJuozas Ramanauskas
Juozas Ramanauskas
VPValdas Paukštys
Valdas Paukštys
Windows, which have a U-value that is governed by an insulating glass unit (IGU) U-value, must be a building’s only enclosure element, which has no design value concept. The declared U-value, which is calculated or measured with 0 °C of external ambient temperature, is used instead of the design value. For most of a building’s elements, its thermal transmittance with a decrease in the external temperature diminishes a little, i.e., improves. However, for modern window IGUs with Low-E coatings, it is the opposite: the thermal transmittance with a lowering external temperature increases. Therefore, for calculating the peak power for the heating of buildings it is necessary to pay attention to this phenomenon and, therefore, it would be wise to introduce the concept of design U-value for windows, recalculation rules, or affix their declared U-values. This is especially the case in modern times with the prevailing architectural tendencies for enlargement of transparent building elements. For IGUs with Low-E coatings and inert gas fillers, the thermal transmittance depends on the temperature difference between warm and cold environments. When the external temperature is −30 °C instead of 0 °C, the thermal transmittance of the IGU can increase by up to 35%. This study presents the thermal properties of windows’ IGUs depending on the changes in outdoor temperatures by using guarded a hot box climate chamber and presents the proposed simplified methodology for determining the thermal properties of windows’ glass units. The accuracy of the composed simplified methods, comparing the calculated thermal transmittances of IGUs with those measured in the “hot box”, were up to 1.25%.

20 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
EMEdmundas Monstvilas
Edmundas Monstvilas
SBSimon Paul Borg
Simon Paul Borg
Rosita NorvaisieneRosita Norvaisiene
Rosita Norvaisiene
Karolis BanionisKarolis Banionis
Karolis Banionis
JRJuozas Ramanauskas
Juozas Ramanauskas
As per general provisions of European Directive 2010/31/EU on the energy efficiency of buildings (recast), the Lithuanian government transposed the Directive into Lithuanian national law. In the process, the Lithuanian government prepared strategic documents in the field of energy performance and renewable energy that were integrated together through the National Energy and Climate Plan for 2021–2030 (NECP). To better understand the current situation vis-à-vis energy performance, the main characteristics of buildings pertaining to the Lithuanian multi-apartment building stock, classified according to their energy performance class, are analysed and discussed in this paper. Through the exploitation of data from the national Energy Performance Certificate (EPC) register, an overview of the energy performance of the existing Lithuanian residential building stock is presented along with an analysis of the unused potential energy savings pertinent to this building category. The results obtained from the analysed data of energy consumption in buildings shows that the policies adopted over the years were successful in improving the building stock, promoting the move towards the specifications required by a Class A++ (nearly zero energy buildings—NZEB) by 2021. The results show that this was primarily achieved by a significant reduction in the thermal energy used for space heating.

29 April 2022 in Buildings
Verified
Journal Article
Open access
PDF file
JŠJolanta Šadauskienė
Jolanta Šadauskienė
JRJuozas Ramanauskas
Juozas Ramanauskas
Dorota KrawczykDorota Krawczyk
Dorota Krawczyk
Egle KlumbyteEgle Klumbyte
Egle Klumbyte
Paris FokaidesParis Fokaides
Paris Fokaides
The investigation of building elements regarding energy saving is a paramount issue, with EU Directives driving achievement goals, focusing on buildings’ energy performance and energy efficiency. This work focuses on investigating thermal bridges in a new high-performance window installation. This work aims to investigate the thermal properties of windows installed in the thermal insulation layer and to compare different installation methods and thermal bridge evaluation methodologies from the point of view of thermal physics. The results show that comparing the obtained values of the thermal bridge according to two- and three-dimensional domain (2-D and 3-D) calculation methods, the values show a difference of 68%. After examining the method of installing a new high-performance window in the thermal insulation layer, the effect of installing a window on the wall of a building is highlighted in this work. Given that windows are the most thermally conductive elements in a building, this paper provides guidance for both the scientific community and practitioners regarding trends in thermal bridges that change completely when using different assessment methods.