Department of Automation and Applied Informatics, Faculty of Automation and Computers, Politehnica University of Timisoara, 14 Remus Str., 300191 Timisoara, Romania
Dr. Florin Dragan
Department of Automation and Applied Informatics, Faculty of Automation and Computers, Politehnica University of Timisoara, 14 Remus Str., 300191 Timisoara, Romania
In this paper, a new analytical approach is proposed to investigate the electrical and mechanical behavior of a low-power permanent magnet synchronous generator (PMSG) in the presence of a wind gust. The proposed model for the wind gust and wind power system was analytically investigated using the optimal auxiliary functions method (OAFM), which has proven to be a reliable tool. The reaction of the system to a wind gust was explicitly obtained, which is useful for stability analysis, protection issues, and risk assessment concerning the PMSG. A substantial reduction of computations in analytically analysing a complicated dynamical system is ensured by this new approach, through some auxiliary functions and convergence-control parameters.
This paper proposes an easily understandable Grey Wolf Optimizer (GWO) applied to the optimal tuning of the parameters of Takagi-Sugeno proportional-integral fuzzy controllers (T-S PI-FCs). GWO is employed for solving optimization problems focused on the minimization of discrete-time objective functions defined as the weighted sum of the absolute value of the control error and of the squared output sensitivity function, and the vector variable consists of the tuning parameters of the T-S PI-FCs. Since the sensitivity functions are introduced with respect to the parametric variations of the process, solving these optimization problems is important as it leads to fuzzy control systems with a reduced process parametric sensitivity obtained by a GWO-based fuzzy controller tuning approach. GWO algorithms applied with this regard are formulated in easily understandable terms for both vector and scalar operations, and discussions on stability, convergence, and parameter settings are offered. The controlled processes referred to in the course of this paper belong to a family of nonlinear servo systems, which are modeled by second order dynamics plus a saturation and dead zone static nonlinearity. Experimental results concerning the angular position control of a laboratory servo system are included for validating the proposed method.
In this paper a second-order data-driven Active Disturbance Rejection Control (ADRC) is merged with a proportional-derivative Takagi-Sugeno Fuzzy (PDTSF) logic controller, resulting in two new control structures referred to as second-order data-driven Active Disturbance Rejection Control combined with Proportional-Derivative Takagi-Sugeno Fuzzy Control (ADRC–PDTSFC). The data-driven ADRC–PDTSFC structure was compared with a data-driven ADRC structure and the control system structures were validated by real-time experiments on a nonlinear Multi Input-Multi Output tower crane system (TCS) laboratory equipment, where the cart position and the arm angular position of TCS were controlled using two Single Input-Single Output control system structures running in parallel. The parameters of the data-driven algorithms were tuned in a model-based way using a metaheuristic algorithm in order to improve the efficiency of energy consumption.
19 December 2022 in Studies in Informatics and Control
The sustainability of the food production achieved with the help of irrigation systems and the sustainability of their energy consumption are major challenges of the current century. Pumping systems currently account for approximately 30% of global electrical energy consumption. As electricity prices rise, there is a growing need for technological advancements to enhance energy efficiency and reduce consumption costs effectively. This study focuses on operating centrifugal pumps at variable frequency as an effective means of achieving this goal. Most centrifugal pump manufacturers/providers traditionally assume that pump efficiency remains constant across various operating frequencies, often equating the efficiency at various frequencies to that at the standard frequency (50/60 Hz). In contrast, this paper introduces a new formula for estimating pump efficiency, crucial to precise power consumption determination, particularly in variable-frequency scenarios. The formula parameters are identified by using experimental data acquired from an existing pumping system. The tests and results presented in this paper demonstrate that the proposed formula outperforms the formulas of the current industry standards in accuracy. Practically, the new relation assures enhanced accuracy in estimating pump efficiency and absorbed power, allowing for the design of a more precise model used for control systems synthesis required for operating centrifugal pumps at variable frequency. This research offers a new way of calculating pump efficiency, which could be very useful for industry practitioners seeking to optimize energy consumption in pumping systems.
14 December 2022 in International Journal of Computers Communications & Control
Digital technology has drastically transformed businesses’ activities, operations, and processes. Today, digital efficiencies have inspired companies to take initiatives to leverage the firm’s environmental performance. The study’s primary purpose was to examine how a digital transformation strategy affects environmental performance under the mediating role of innovation capabilities and moderating role of digital organizational culture. The data was obtained from manufacturing industry employees in Pakistan. The results reveal that digital transformation strategy (DTS) positively and significantly affects innovation capabilities and environmental performance. The link between digital transformation and environmental performance is mediated by innovation capabilities, while digital organizational culture moderates the relationship between innovation capabilities and environmental performance.