Iosif Szeidert

Dr. Iosif Szeidert

Politehnica University Timisoara, Bvd. V. Parvan, no.2, 300223, Timisoara, Romania
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
DBDorin Bordeasu
Dorin Bordeasu
Florin DraganFlorin Dragan
Florin Dragan
IFIoan Filip
Ioan Filip
Iosif SzeidertIosif Szeidert
Iosif Szeidert
GTGELU OVIDIU TIRIAN
GELU OVIDIU TIRIAN
The sustainability of the food production achieved with the help of irrigation systems and the sustainability of their energy consumption are major challenges of the current century. Pumping systems currently account for approximately 30% of global electrical energy consumption. As electricity prices rise, there is a growing need for technological advancements to enhance energy efficiency and reduce consumption costs effectively. This study focuses on operating centrifugal pumps at variable frequency as an effective means of achieving this goal. Most centrifugal pump manufacturers/providers traditionally assume that pump efficiency remains constant across various operating frequencies, often equating the efficiency at various frequencies to that at the standard frequency (50/60 Hz). In contrast, this paper introduces a new formula for estimating pump efficiency, crucial to precise power consumption determination, particularly in variable-frequency scenarios. The formula parameters are identified by using experimental data acquired from an existing pumping system. The tests and results presented in this paper demonstrate that the proposed formula outperforms the formulas of the current industry standards in accuracy. Practically, the new relation assures enhanced accuracy in estimating pump efficiency and absorbed power, allowing for the design of a more precise model used for control systems synthesis required for operating centrifugal pumps at variable frequency. This research offers a new way of calculating pump efficiency, which could be very useful for industry practitioners seeking to optimize energy consumption in pumping systems.

1 July 2016 in Expert Systems with Applications
Verified
Journal Article
Closed access
IFIoan Filip
Ioan Filip
Iosif SzeidertIosif Szeidert
Iosif Szeidert

21 July 2018 in European Journal of Control
Verified
Journal Article
Closed access
IFIoan Filip
Ioan Filip
Cristian VasarCristian Vasar
Cristian Vasar
Iosif SzeidertIosif Szeidert
Iosif Szeidert
Octavian ProsteanOctavian Prostean
Octavian Prostean

1 September 2017 in European Journal of Control
Verified
Journal Article
Closed access
IFIoan Filip
Ioan Filip
Iosif SzeidertIosif Szeidert
Iosif Szeidert

27 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
IFIoan Filip
Ioan Filip
FDFlorin Dragan
Florin Dragan
Iosif SzeidertIosif Szeidert
Iosif Szeidert
AAAdriana ALBU
Adriana ALBU
The present paper proposes (as the main contribution) an additional self-tuning mechanism for an adaptive minimum-variance control system, whose main goal is to extend its functionality for a large value range of unmeasurable perturbations which disturb the controlled process. Through the standard design procedure, a minimum variance controller uses by default an internal self-tuning mechanism based on the process parameter estimates. However, the main parameter which overwhelmingly influences the control performance is the control penalty factor ( ρ ) . This parameter weights the term that describes the control variance in a criterion function whose minimization is the starting point of the control law design. The classical minimum-variance control involves an off-line tuning of this parameter, its value being set as constant throughout the entire operating regime. Based on the measurement of the process output error, the contribution of the proposed strategy consists in a real-time tuning of the control penalty factor, to ensure the stability of the control system, even under conditions of high disturbances. The proposed tuning mechanism adjusts this parameter by implementing a bipositional switching strategy based on a sharp hysteresis loop. Therefore, instead of the standard solution that involves a constant value of the control penalty factor ρ (a priori computed and set), this paper proposes a dual value for this controller parameter. The main objective is to allow the controlled process to operate in a stable fashion even in more strongly disturbed regimes (regimes where the control system becomes unstable and is usually switched off for safety reasons). To validate the proposed strategy, an induction generator integrated into a wind energy conversion system was considered as controlled plant. Operating under the action of strong disturbances (wind gusts, electrical load variations), the extension of safe operating range (thus avoiding the system disengagement) is an important goal of such a control system.

1 October 2007
Verified
Conference Paper
Closed access
Lucian MihetLucian Mihet
Lucian Mihet
VGV. Groza
V. Groza
Gabriela ProsteanGabriela Prostean
Gabriela Prostean
IFIoan Filip
Ioan Filip
Iosif SzeidertIosif Szeidert
Iosif Szeidert
In this paper, the performance of variable speed wind turbine concept with cage rotor induction generator connected to the grid is investigated. Variable-speed wind turbine generator system has been modeled and simulated to study their steady state and dynamic behavior. A cage rotor induction machine of 11 kW rating with a vector controlled back-to-back PWM-VSI inverter on the stator side have been tested and the results compared with digital simulations. The cage rotor induction machine allows good speed range and it should be used in low-power variable-speed systems, replacing the classical direct grid connected fixed speed wind generator systems. Its capacity to deliver reactive power is remarkable.