Ulya Farahdina

Ms. Ulya Farahdina


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2023 in Molecules
Verified
Journal Article
Open access
PDF file
VZVinda Zakiyatuz Zulfa
Vinda Zakiyatuz Zulfa
Nasori NasoriNasori Nasori
Nasori Nasori
UFUlya Farahdina
Ulya Farahdina
MFMiftakhul Firdhaus
Miftakhul Firdhaus
IAIhwanul Aziz
Ihwanul Aziz
Agus RubiyantoAgus Rubiyanto
Agus Rubiyanto
The fabrication of a ZnO/Au nanosquare-array electrode was successfully carried out for the detection of glucose concentration in biomedical applications. The fabrication of the ZnO/Au nanosquare array using an ultra-thin alumina mask (UTAM) based on the imprinted anodic aluminum oxide (AAO) template and the direct current (DC) sputtering method was able to produce a very well-ordered nanosquare arrangement with a side size of 300 nm and a thickness of 100 nm. Tests were done to evaluate the performance of the electrode by means of cyclic voltammetry (CV) which showed that the addition of glucose oxidase (GOx) increased the sensitivity of the electrode up to 1180 ± 116 μA mM−1cm−2, compared with its sensitivity prior to the addition of GOx of 188.34 ± 18.70 mA mM−1 cm−2. A iox/ired ratio equal to ~1 between the peaks of redox reactions was obtained for high (hyperglycemia), normal, and low (hypoglycemia) levels of glucose. The ZnO/Au nanosquare-array electrode was 7.54% more sensitive than the ZnO/Au thin-film electrode. Furthermore, finite-difference time-domain (FDTD) simulations and theoretical calculations of the energy density of the electric and magnetic fields produced by the ZnO/Au electrode were carried out and compared to the results of CV. From the results of CV, FDTD simulation, and theoretical calculations, it was confirmed that the ZnO/Au nanosquare array possessed a significant optical absorption and that the quantum effect from the nanosquare array resulted in a higher sensitivity than the thin film.

13 May 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Nasori NasoriNasori Nasori
Nasori Nasori
DCDawei Cao
Dawei Cao
ZWZhijie Wang
Zhijie Wang
UFUlya Farahdina
Ulya Farahdina
ARAgus Rubiyanto
Agus Rubiyanto
Yong LeiYong Lei
Yong Lei
The fabrication of the photoanode of the n-type CuWO4 nanorod arrays was successfully carried out through electrochemical deposition using anodic aluminum oxide (AAO) control templates and for the first time produced distinct gaps between the nanorod arrays. The effectiveness and efficiency of the resulting deposition was shown by the performance of the photoelectrochemical (PEC) procedure with a current density of 1.02 mA cm−2 with irradiation using standard AM 1.5G solar simulator and electron changed radiation of 0.72% with a bias potential of 0.71 V (vs. Ag/AgCl). The gap between each nanorod indicated an optimization of the electrolyte penetration on the interface, which resulted in the expansion of the current density as much as 0.5 × 1024 cm−3 with a flat band potential of 0.14 V vs. Ag/AgCl and also a peak quantum efficiency of wavelength 410 nm. Thus, also indicating the gaps between the nanorod arrays is a promising structure to optimize the performance of the PEC water splitting procedure as a sustainable energy source.

18 November 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Nasori NasoriNasori Nasori
Nasori Nasori
UFUlya Farahdina
Ulya Farahdina
VZVinda Zakiyatuz Zulfa
Vinda Zakiyatuz Zulfa
MFMiftakhul Firdhaus
Miftakhul Firdhaus
IAIhwanul Aziz
Ihwanul Aziz
Agus RubiyantoAgus Rubiyanto
Agus Rubiyanto
The development of silver (Ag) thin films and the fabrication of Ag nanosquare arrays with the use of an anodic aluminum oxide (AAO) template and leaf extracts were successfully carried out using the DC sputtering and spin coating deposition methods. Ag thin films and Ag nanosquare arrays are developed to monitor cancer prognosis due to the correlation between serum albumin levels and prognostic factors, as well as the binding of serum albumin to the surface of these electrodes. Nanosquare structures were fabricated using AAO templates with varying diameters and a gap distance between adjacent unit cells of 100 nm. The nanosquare array with a diameter of 250 nm and irradiated with electromagnetic waves with a wavelength of around 800 nm possessed the greatest electric field distribution compared to the other variations of diameters and wavelengths. The results of the absorption measurement and simulation showed a greater shift in absorption peak wavelength when carried out using the Ag nanosquare array. The absorption peak wavelengths of the Ag nanosquare array in normal blood and blood with cancer lymphocytes were 700–774 nm and 800–850 nm, respectively. The electrochemical test showed that the sensitivity values of the Ag thin-film electrode deposited using DC sputtering, the Ag thin-film electrode deposited using spin coating, and the Ag nanosquare array in detecting PBS+BSA concentration in the cyclic voltammetry (CV) experiment were 1.308 µA mM−1cm−2, 0.022 µA mM−1cm−2, and 39.917 µA mM−1cm−2, respectively. Meanwhile, the sensitivity values of the Ag thin film and the Ag nanosquare array in detecting the PBS+BSA concentration in the electrochemical impedance spectroscopy (EIS) measurement were 6593.76 Ohm·cm2/mM and 69,000 Ohm·cm2/mM, respectively. Thus, our analysis of the optical and electrochemical characteristics of Ag thin films and Ag nanosquare arrays showed that both can be used as an alternative biomedical technology to monitor the prognosis of blood cancer based on the concentration of serum albumin in blood.

14 January 2023 in Coatings
Verified
Journal Article
Open access
PDF file
UFUlya Farahdina
Ulya Farahdina
AMAmastasia Salsabila Muliawati
Amastasia Salsabila Muliawati
VZVinda Zakiyatuz Zulfa
Vinda Zakiyatuz Zulfa
MFMiftakhul Firdhaus
Miftakhul Firdhaus
IAIhwanul Aziz
Ihwanul Aziz
Agus RubiyantoAgus Rubiyanto
Agus Rubiyanto
The fabrication of silver (Ag) and gold (Au) thin film electrodes was successfully carried out using the DC sputtering deposition method. These thin film electrodes were able to detect the increase in serum albumin concentration that was used as a prognostic factor for leukemia. The simulation and the optical experimental analysis show that an increase in BSA concentration can increase the absorbance peak observed at a wavelength of 435 nm on hypoalbumin medium and 470 nm on normal concentration of serum albumin medium. The performance of the electrodes was electrochemically tested, in which it was shown that a decrease in oxidation and reduction peaks occurred with respect to an increase in BSA concentration. An oxidation peak was observed at a voltage of 0.5 V for the Ag thin film. For the Au, Au/Ag, and Ag/Au thin films, an oxidation peak was observed at a voltage of 1.0 V. The limits of detection (LODs) of the Ag, Ag/Au, Au, and Au/Ag thin films were 0.56, 0.24, 0.64, and 0.36 g/dL, respectively. Therefore, based on both the electrochemical and optical analysis, the Ag/Au thin film possessed the highest potential for prognosis monitoring of leukemia compared with the other Ag and Au thin films.

1 January 2024 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
UFUlya Farahdina
Ulya Farahdina
VZVinda Zakiyatuz Zulfa
Vinda Zakiyatuz Zulfa
EEEndarko Endarko
Endarko Endarko
Nasori NasoriNasori Nasori
Nasori Nasori
ARAgus Rubiyanto
Agus Rubiyanto
Combinations of various types and structures of materials were developed to obtain highest sensitivity of biosensor. The optical analysis of the electric field

15 March 2025 in Jurnal Penelitian Sains
Verified
Journal Article
Open access
PDF file
NANadine Nova Arini
Nadine Nova Arini
SBShahwa Namira Bisri
Shahwa Namira Bisri
JJJaenuri Jaenuri
Jaenuri Jaenuri
UFUlya Farahdina
Ulya Farahdina
Due to weather instability in recent years, dried fish production in Indonesia has declined, while the quality of the produced dried fish remains low. To address this challenge, the authors introduce "SMART FISH DRYING," an automatic fish drying system based on a transparent greenhouse structure. This system uses acrylic walls and a convex lens roof that focuses sunlight. Inside "SMART FISH DRYING," fish are arranged on a stainless steel wire mesh table equipped with a humidity sensor that automatically rotates the table when the fish's moisture content on one side reaches 30%. When both sides reach the desired moisture level, an LED light and alarm activate, signaling that the dried fish is ready for harvesting. "SMART FISH DRYING" operates using solar cells connected to a battery, significantly reducing energy consumption and operational costs. Additionally, the system features a gas collection system to capture H?S compounds released during the drying process, which can be processed into pesticides. This process is monitored by an MQ136 gas sensor to measure the concentration of harmful compounds. Moreover, "SMART FISH DRYING" optimizes the moisture from the drying process through a distillation system to produce purified water as a byproduct. With this technology, dried fish production can be accelerated by two times compared to traditional methods, with a fourfold increase in profitability and a 20% improvement in product quality.Keywords: dried fish; convex lens; automatic; solar.