Horia Octavian Manolea

Prof. Dr. Horia Octavian Manolea

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VGVlad Alexandru Georgeanu
Vlad Alexandru Georgeanu
OGOANA Gingu
OANA Gingu
Antoniac IulianAntoniac Iulian
Antoniac Iulian
Horia Octavian ManoleaHoria Octavian Manolea
Horia Octavian Manolea
The ideal biomaterials substitute for bone repair should possess the following characteristics: provide osteogenic, osteoinductive and osteoconductive properties; stimulate the neo-angiogenesis process; absence of antigenic, teratogenic or carcinogenic reactions; avoid the systemic toxicity complications; assure satisfactory support and stability from mechanical properties point of view; hydrophilic nature of the surface properties and good interface with human bone; good handling in clinical condition and ability to be easy sterilized; and able to be supplied in sufficient quantities with reduced costs. Despite years of effort, the perfect bone reconstruction material has not yet been developed; further effort is required to make this objective feasible. The aim of this article is to provide a contemporary and comprehensive overview of the grafting materials that can be applied for the treatment of bone defects by the clinicians from orthopedics surgery, neurosurgery and dentistry, discussing their properties, advantages and disadvantages, and illuminating present and future perspectives in the field of bone graft and biomaterials substitutes for bone repair, from clinical needs to advanced biomaterials research.

Verified
Journal Article
Open access
PDF file
Târtea Daniel AdrianTârtea Daniel Adrian
Târtea Daniel Adrian
MIMihaela Ionescu
Mihaela Ionescu
Horia Octavian ManoleaHoria Octavian Manolea
Horia Octavian Manolea
VMVeronica Mercuț
Veronica Mercuț
EOEugenia Obădan
Eugenia Obădan
Mihaela PopescuMihaela Popescu
Mihaela Popescu
The implementation of CAD-CAM systems in dentistry has significantly influenced the evolution of dental implantology and implant-supported prosthetics within the past three decades. Implant-supported prostheses are comfortable and aesthetic. The prosthetic abutment has also faced a rapid design evolution, from the individualization of standard stock abutments offered by various manufacturers to a modern customization process using CAD-CAM technology. This paper presents a comparative study between 20 dental custom CAD-CAM implant abutments and 20 dental implant stock abutments, based on a set of measurements performed on the digital casts obtained from 24 cases of prosthetic rehabilitation on implants. The statistical analysis (Mann–Whitney U test) revealed significant differences between these two types of abutments: the incisal margin line diameter dimensions for custom abutments were significantly improved compared to standard abutments at the cervical level (U = 343.00, z = 3.868, p < 0.0005) and the incisal/occlusal level (U = 352.00, z = 4.112, p < 0.0005), while the inclination angle of the custom abutments relative to the 0-axis was significantly smaller than that of standard abutments (U = 115.50, z = −2.286, p = 0.022). The use of custom abutments leads to an increase in the final size of the abutment, an improvement in the retention of the prosthetic work, and reduces the angulation of the abutment in relation to the implant axis, thus decreasing the risk of unscrewing or fracturing the dental screw.

DVDiana Elena Vlăduțu
Diana Elena Vlăduțu
MIMihaela Ionescu
Mihaela Ionescu
LNLorenzo Noveri
Lorenzo Noveri
Horia Octavian ManoleaHoria Octavian Manolea
Horia Octavian Manolea
MSMonica Scrieciu
Monica Scrieciu
VMVeronica Mercuț
Veronica Mercuț
This study evaluated the occlusal relationships in students with bruxism, using the T-Scan III system, and their correlation with the activity of the masticatory muscles assessed through surface electromyography (sEMG). The study group was divided into two subgroups (based on self-reporting): 20 participants with possible bruxism and 20 participants without possible bruxism; all participants underwent the following evaluations: sEMG recordings using the dia-BRUXO device for masticatory muscles assessment, as well as static and dynamic occlusion using the T-SCAN III system. The analysis of the maximum intercuspidal (MI) position revealed a positive moderate association between the values of the occlusal forces in MI distributed along the two hemiarches, and the number of grinding events during daytime, which was statistically significant (p < 0.05). The analysis of protrusion movements reflected statistically significant differences between the non-working interferences and sEMG parameters specific to bruxism (p < 0.05). The analysis of laterotrusion movements indicated that participants with anterolateral guidance presented higher values of awake bruxism indexes and higher values of clenching events during nighttime. For all three mandibular movements, their duration was higher for the study group compared to the control group. Therefore, this study confirmed the utility of sEMG recordings in the bruxism diagnosis process, as well as the association between dental occlusion and bruxism.

DVDiana Elena Vlăduțu
Diana Elena Vlăduțu
MIMihaela Ionescu
Mihaela Ionescu
RMRăzvan Mercuț
Răzvan Mercuț
LNLorenzo Noveri
Lorenzo Noveri
GLGrigore Lăzărescu
Grigore Lăzărescu
VMVeronica Mercuț
Veronica Mercuț
According to the International Bruxism Consensus, bruxism refers to the activity of the masticatory muscles reflecting contraction disorders, regardless of whether it is during sleep (SB) or an awake (AB) state. The objective of the present study was to evaluate the activity of the masseter muscle by surface electromyographic (sEMG) recordings. This study was performed on 20 participants with self-reported “possible bruxism” (study group) and 20 participants with no self-reported bruxism (control group); all participants underwent an evaluation of the masseter muscle activity using the dia-BRUXO device, which provides numerical parameters regarding sEMG (the total duration and the type of bruxism specific events, the effort made by the masticatory muscles during the recording period, and the personal bruxism index of each participant). Participants from the study group presented more clenching events during AB, three times more frequent than the control group (p = 0.002, Mann–Whitney U test); for SB, the frequency of clenching and grinding events was comparable within the study group, being more frequent than for the control group; the mean value of the effort index was higher for AB (1.177%) than SB (0.470%) and the same for the duration index, with a mean value of 2.788% for AB and 1.054% for SB. All participants from the control group presented reduced values for all acquired parameters. Overall, the personal bruxism index in AB was approximately four times higher for the study group (2.251%) compared to the control group (0.585%) (p < 0.005, Mann–Whitney U test). Similar values were obtained for SB. All participants with “possible bruxism” from the study group presented a higher activity of the masseter muscle, which is specific for bruxism, thus being defined as “definite bruxism”.

Verified
Journal Article
Open access
PDF file
IIIoana Ioana
Ioana Ioana
FBFilip George Boeru
Filip George Boeru
Antoniac IulianAntoniac Iulian
Antoniac Iulian
IMIoana Mitrut
Ioana Mitrut
ISIonela Elisabeta Staicu
Ionela Elisabeta Staicu
Horia Octavian ManoleaHoria Octavian Manolea
Horia Octavian Manolea
Temporary anchorage devices (TADs) are orthodontic mini-implants with remarkable characteristics that, once inserted, present mechanical retention (primary stability) without the process of bone osseointegration. However, interaction with the biological environment may cause changes in the morphology of the external surface of dental TADs. In this study, we used 17 TADs made of aluminum–vanadium titanium alloy, produced by two companies, which were analyzed through optical microscopy after being removed from the patients during orthodontic treatment. We evaluated the changes that appeared on the TADs’ surfaces after their use in the biological environment, depending on the morphological area in which they were inserted. In our study, we found changes in the morphology of the implant surface, and especially deposits of biological material in all study groups. On all samples examined after clinical use, regardless of the period of use, corrosion surfaces in different locations were observed. Our obtained results support the idea that the biological environment is aggressive for mini-implant structures, always producing changes to their surface during their clinical use.

3 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
AKAntonia Samia Khaddour
Antonia Samia Khaddour
RGRăzvan Eugen Ghiță
Răzvan Eugen Ghiță
MIMihaela Ionescu
Mihaela Ionescu
RRRadu Gabriel Rîcă
Radu Gabriel Rîcă
VMVeronica Mercuț
Veronica Mercuț
Mihaela PopescuMihaela Popescu
Mihaela Popescu
Background: Over time, numerous surgical procedures and biomaterials have been proposed for the reconstruction of post-extraction bone defects, each with their advantages and disadvantages. The main objective of this study was to evaluate dimensional changes in the alveolar bone 3 months after tooth extraction, before implant planning, comparing alveolar ridge preservation (ARP) with spontaneous healing. Methods: A total of 84 patients with non-restorable molars were included in the study. Forty-two patients received ARP with advanced platelet-rich fibrin (A-PRF) and spontaneous healing was evaluated in these patients. Cone beam computed tomography (CBCT) analysis performed before and after surgical intervention was used to determine the changes in vertical and horizontal bone dimensions produced after tooth extraction. Results: CBCT measurements showed reduction in both vertical and horizontal alveolar bone size in both groups. For the study group, the alveolar parameters (height, width) were higher compared to the control group. The percentage variations between dimensional differences from the two groups were 38.58% for height, and for width were 36.88% at 0 mm, 35.56% at 3 mm, 36.61% at 5 mm, and 38.73% at 7 mm. The differences were statistically significant (p ˂ 0.0005). Conclusions: The results obtained after ARP with A-PRF showed a reduced loss of bone volume compared to spontaneous healing.