Dahnan Spurling

Mr. Dahnan Spurling

Trinity College Dublin
+2
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2024 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Open access
RBRajiv Borah
Rajiv Borah
JOJulia O'SUllivan
Julia O'SUllivan
Meenakshi SukuMeenakshi Suku
Meenakshi Suku
DSDahnan Spurling
Dahnan Spurling
DCDaniel Diez Clarke
Daniel Diez Clarke
MMMichael Monaghan
Michael Monaghan
With no effective treatments for functional recovery after injury, spinal cord injury (SCI) remains one of the unresolved healthcare challenges. Human induced pluripotent stem cell (hiPSC) transplantation is a versatile patient‐specific regenerative approach for functional recovery after SCI. Injectable electroconductive hydrogel (ECH) can further enhance the cell transplantation efficacy through a minimally invasive manner as well as recapitulate the native bioelectrical microenvironment of neural tissue. Given these considerations, we report a novel ECH prepared through self‐assembly facilitated in situ gelation of natural silk fibroin (SF) derived from mulberry Bombyx mori silk and electrically conductive PEDOT:PSS. PEDOT:PSS was pre‐stabilized to prevent the potential delamination of its hydrophilic PSS chain under aqueous environment using 3% (v/v) (3‐glycidyloxypropyl)trimethoxysilane (GoPS) and 3% (w/v) poly(ethylene glycol)diglycidyl ether (PeGDE). The resultant ECH formulations are easily injectable with standard hand force with flow point below 100 Pa and good shear‐thinning properties. The ECH formulations with unmodified and GoPS‐modified PEDOT:PSS, that is, SF/PEDOT and SF/PEDOTGoP maintain comparable elastic modulus to spinal cord (~10–60 kPa) under physiological condition, indicating their flexibility. The GoPS‐modified ECHs also display improved structural recoverability (~70%–90%) as compared to the unmodified versions of the ECHs (~30%–80%), as indicated by the three interval time thixotropy (3ITT) test. Additionally, these ECHs possess electrical conductivity in the range of ~0.2–1.2 S/m comparable to spinal cord (1–10 S/m), indicating their ability to mimic native bioelectrical environment. Approximately 80% or more cell survival was observed when hiPSC‐derived cortical neurons and astrocytes were encapsulated within these ECHs. These ECHs support the maturation of cortical neurons when embedded for 7 days, fostering the development of a complex, interconnected network of long axonal processes and promoting synaptogenesis. These results underline the potential of silk ECHs in cell transplantation therapy for spinal cord regeneration.

15 July 2025 in Advanced Science
Verified
Journal Article
Open access
IWIan Woods
Ian Woods
DSDahnan Spurling
Dahnan Spurling
SSSandra Sunil
Sandra Sunil
AOAnne Marie O'CAllaghan
Anne Marie O'CAllaghan
JMJack Maughan
Jack Maughan
Fergal O'BrienFergal O'Brien
Fergal O'Brien
No effective treatments are currently available for central nervous system neurotrauma although recent advances in electrical stimulation suggest some promise in neural tissue repair. It is hypothesized that structured integration of an electroconductive biomaterial into a tissue engineering scaffold can enhance electroactive signaling for neural regeneration. Electroconductive 2D Ti 3 C 2 T x MXene nanosheets are synthesized from MAX‐phase powder, demonstrating excellent biocompatibility with neurons, astrocytes and microglia. To achieve spatially‐controlled distribution of these MXenes, melt‐electrowriting is used to 3D‐print highly‐organized PCL micro‐meshes with varying fiber spacings (low‐, medium‐, and high‐density), which are functionalized with MXenes to provide highly‐tunable electroconductive properties (0.081 ± 0.053‐18.87 ± 2.94 S/m). Embedding these electroconductive micro‐meshes within a neurotrophic, immunomodulatory hyaluronic acid‐based extracellular matrix (ECM) produced a soft, growth‐supportive MXene‐ECM composite scaffold. Electrical stimulation of neurons seeded on these scaffolds promoted neurite outgrowth, influenced by fiber spacing in the micro‐mesh. In a multicellular model of cell behavior, neurospheres stimulated for 7 days on high‐density MXene‐ECM scaffolds exhibited significantly increased axonal extension and neuronal differentiation, compared to low‐density scaffolds and MXene‐free controls. The results demonstrate that spatial‐organization of electroconductive materials in a neurotrophic scaffold can enhance repair‐critical responses to electrical stimulation and that these biomimetic MXene‐ECM scaffolds offer a promising new approach to neurotrauma repair.

29 June 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
NTNicola Taurisano
Nicola Taurisano
GBGianluca Bravetti
Gianluca Bravetti
SCSonia Carallo
Sonia Carallo
MLMeiying Liang
Meiying Liang
OROskar Ronan
Oskar Ronan
Aurora RizzoAurora Rizzo
Aurora Rizzo
Organic–inorganic hybrid perovskite materials have raised great interest in recent years due to their excellent optoelectronic properties, which promise stunning improvements in photovoltaic technologies. Moreover, two-dimensional layered materials such as graphene, its derivatives, and transition metal dichalcogenides have been extensively investigated for a wide range of electronic and optoelectronic applications and have recently shown a synergistic effect in combination with hybrid perovskite materials. Here, we report on the inclusion of liquid-phase exfoliated molybdenum disulfide nanosheets into different perovskite precursor solutions, exploring their influence on final device performance. We compared the effect of such additives upon the growth of diverse perovskites, namely CH3NH3PbI3 (MAPbI3) and triple-cation with mixed halides Csx (MA0.17FA0.83)(1−x)Pb (I0.83Br0.17)3 perovskite. We show how for the referential MAPbI3 materials the addition of the MoS2 additive leads to the formation of larger, highly crystalline grains, which result in a remarkable 15% relative improvement in power conversion efficiency. On the other hand, for the mixed cation–halide perovskite no improvements were observed, confirming that the nucleation process for the two materials is differently influenced by the presence of MoS2.

5 March 2023 in Electrochimica Acta
Verified
Journal Article
Open access
SRSeán Ryan
Seán Ryan
MBMichelle P. Browne
Michelle P. Browne
Ainur ZhussupbekovaAinur Zhussupbekova
Ainur Zhussupbekova
DSDahnan Spurling
Dahnan Spurling
LMLorcan McKeown
Lorcan McKeown
VNValeria Nicolosi
Valeria Nicolosi

1 December 2021 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
Michela BorghettiMichela Borghetti
Michela Borghetti
Mauro SerpelloniMauro Serpelloni
Mauro Serpelloni
Emilio SardiniEmilio Sardini
Emilio Sardini
DSDahnan Spurling
Dahnan Spurling
VNValeria Nicolosi
Valeria Nicolosi

14 February 2026 in Biomaterials
Verified
Journal Article
Open access
RBRajiv Borah
Rajiv Borah
JOJulia O'SUllivan
Julia O'SUllivan
DSDahnan Spurling
Dahnan Spurling
AMAoife McLoughlin
Aoife McLoughlin
DADiana Eveline Sanchez Amador
Diana Eveline Sanchez Amador
MMMichael Monaghan
Michael Monaghan
Spinal cord injury (SCI) remains a major clinical challenge due to its complex pathophysiology and lack of effective treatments. While electrical stimulation (ES) offers therapeutic potential for promoting neural repair, its clinical translation is limited by the invasiveness of conventional systems. Here, we report a non-invasive wireless electrical stimulation (WES) platform based on charge polarisation-induced capacitive coupling, enabled by a conductive silk fibroin/PEDOT:PSS (SF/PEDOT) hydrogel. SF/PEDOT hydrogels exhibit a tuneable mechanical stiffness (2-120 kPa), injectable delivery (<5 N injection force), and electrical conductivity (∼0.3 S/m) closely matching the spinal cord. This hydrogel platform has low charge transfer resistance and enhanced capacitive behaviour, supporting efficient non-invasive capacitive coupling for secondary field transduction at low frequencies (∼10 kHz). Using this WES system, we demonstrated modulation of human blood-derived macrophages (hBDMs) toward a reparative phenotype, while downregulating pro-inflammatory markers even under inflammatory conditions. In parallel, hiPSC derived cortical astrocytes (CTX-ASTRO) encapsulated within SF/PEDOT hydrogels showed enhanced functional maturation under WES, evidenced by upregulated connexin 43 (Cx43) gap junction protein expression. In an in vitro SCI-like model of reactive astrogliosis, WES via SF/PEDOT partially mitigated astrocytic reactivity by reducing CXCL10, GM-CSF, and IL-6 secretion and increasing Cx43 expression. Conditioned media from WES treated CTX-ASTRO further suppressed pro-inflammatory activation of hBDMs. Together, these results provide the first evidence of the dual neuroprotective and immunomodulatory potential of a non-invasive, conductive hydrogel-based WES platform, validated using two human cell types specific to SCI pathophysiology. Thus, this approach offers a minimally invasive, translationally relevant solution for spinal cord repair via non-invasive neuromodulation.