Mahmoud Hussein

Dr. Mahmoud Hussein

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2021 in IEEE Access
Verified
Journal Article
Open access
ARAbdelhady Ramadan
Abdelhady Ramadan
Salah KamelSalah Kamel
Salah Kamel
MHMahmoud Hussein
Mahmoud Hussein
Mohamed Hosny HassanMohamed Hosny Hassan
Mohamed Hosny Hassan
The precision of the PV model greatly influences the simulation results to enhance the effectiveness of photovoltaic (PV) energy systems. The PV mathematical model is based on a remarkably nonlinear relationship of its I-V characteristic. The data sheets of overall PV cells do not supply complete information of its parameters. This leads to a nonlinear mathematical model of PV with numerous unknown parameters. Consequently, in this paper, a new application of an appropriate optimization algorithm called Chaos Game Optimization algorithm (CGO) is proposed for estimating the unknown parameters of the three-diode (TD) PV model. The simulation results are carried out for PV real cells and PV module which with varying the temperature and irradiation. The proposed model of the PV module is evaluated by matching its results with the actual PV modules experimental results. To confirm the performance of the CGO algorithm in extracting the parameters of the PV model, its results are compared with the most present and robust techniques results in the literature. The results show that the CGO algorithm attains the least Root Mean Square Error (RMSE), the mean and standard deviation as the best solution. In addition, CGO provides the smallest implementation time compared with the other investigated algorithms.

11 April 2013 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MHMahmoud Hussein
Mahmoud Hussein
Tomonobu SenjyuTomonobu Senjyu
Tomonobu Senjyu
MOMohamed Orabi
Mohamed Orabi
MWMohamed A. A. Wahab
Mohamed A. A. Wahab
MHMohamed M. Hamada
Mohamed M. Hamada
This paper presents a simple control strategy for the operation of a variable speed stand-alone wind turbine with a permanent magnet synchronous generator (PMSG). The PMSG is connected to a three phase resistive load through a switch mode rectifier and a voltage source inverter. Control of the generator side converter is used to achieve maximum power extraction from the available wind power. Control of the DC-DC bidirectional buck-boost converter, which is connected between batteries bank and DC-link voltage, is used to maintain the DC-link voltage at a constant value. It is also used to make the batteries bank stores the surplus of wind energy and supplies this energy to the load during a wind power shortage. The load side voltage source inverter uses a relatively complex vector control scheme to control the output load voltage in terms of amplitude and frequency. The control strategy works under wind speed variation as well as with variable load. Extensive simulation results have been performed using MATLAB/SIMULINK.

14 August 2019 in IEEE Systems Journal
Verified
Journal Article
Closed access
Karar MahmoudKarar Mahmoud
Karar Mahmoud
MHMahmoud Hussein
Mahmoud Hussein
Mohamed Abdel-NasserMohamed Abdel-Nasser
Mohamed Abdel-Nasser
Matti LehtonenMatti Lehtonen
Matti Lehtonen
The intermittent photovoltaic (PV) units significantly affect the performance of distribution systems, and they often cause several operational problems, most importantly, voltage rise/drop. At high PV penetration, excessive tap movements of transformers and high curtailed PV power are expected to completely solve the voltage violation problem. In this paper, we propose an optimal voltage control method for distribution systems considering the number of tap movements of transformers and the active power curtailment of PV units. The objective function of the proposed method comprises: 1) voltage drop violation, 2) voltage rise violation, 3) tap movement rate (TMR) of transformers, and 4) curtailed power of PV (CPPV). A multiobjective grey wolf optimizer integrated with a Lévy mutation operator (GWO-Lévy) is formulated to accurately solve the voltage control problem. A 24-h simulation is performed on the 119-bus distribution system with PV and different types of loads. The performance of GWO-Lévy is compared with three other optimizers, finding that it achieves the best performance. The simulation results demonstrate the efficacy of the proposed method for solving the voltage violation problem with PV while simultaneously optimizing TMR and CPPV.

28 March 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LYliu yang
liu yang
LNLoai S. Nasrat
Loai S. Nasrat
MBMohamed E. Badawy
Mohamed E. Badawy
DWDaniel Eutyche Mbadjoun Wapet
Daniel Eutyche Mbadjoun Wapet
MOManar A. Ourapi
Manar A. Ourapi
Abdallah Elshawadfy ElwakeelAbdallah Elshawadfy Elwakeel
Abdallah Elshawadfy Elwakeel
Egypt is among the world’s largest producers of sugarcane. This crop is of great economic importance in the country, as it serves as a primary source of sugar, a vital strategic material. The pre-cutting planting mode is the most used technique for cultivating sugarcane in Egypt. However, this method is plagued by several issues that adversely affect the quality of the crop. A proposed solution to these problems is the implementation of a sugarcane-seed-cutting device, which incorporates automatic identification technology for optimal efficiency. The aim is to enhance the cutting quality and efficiency of the pre-cutting planting mode of sugarcane. The developed machine consists of a feeding system, a node scanning and detection system, a node cutting system, a sugarcane seed counting and monitoring system, and a control system. The current research aims to study the pulse widths (PW) of three-color channels (R, G, and B) of the RGB color sensors under laboratory conditions. The output PW of red, green, and blue channel values were recorded at three color types for hand-colored nodes [black, red, and blue], three speeds of the feeding system [7.5 m/min, 5 m/min, and 4.3 m/min], three installing heights of the RGB color sensors [2.0 cm, 3.0 cm, and 4.0 cm], and three widths of the colored line [10.0 mm, 7.0 mm, and 3.0 mm]. The laboratory test results s to identify hand-colored sugarcane nodes showed that the recognition rate ranged from 95% to 100% and the average scanning time ranged from 1.0 s to 1.75 s. The capacity of the developed machine ranged up to 1200 seeds per hour. The highest performance of the developed machine was 100% when using hand-colored sugarcane stalks with a 10 mm blue color line and installing the RGB color sensor at 2.0 cm in height, as well as increasing the speed of the feeding system to 7.5 m/min. The use of IoT and RGB color sensors has made it possible to get analytical indicators like those achieved with other automatic systems for cutting sugar cane seeds without requiring the use of computers or expensive, fast industrial cameras for image processing.

15 October 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Abdallah Elshawadfy ElwakeelAbdallah Elshawadfy Elwakeel
Abdallah Elshawadfy Elwakeel
MGMohsen A Gameh
Mohsen A Gameh
AOAwad Ali Tayoush Oraiath
Awad Ali Tayoush Oraiath
IEI. M. Elzein
I. M. Elzein
AEAhmed S Eissa
Ahmed S Eissa
Khaled A. MetwallyKhaled A. Metwally
Khaled A. Metwally
The purpose of this study is to investigate how a tracking indirect solar dryer (SD) powered by photovoltaic cells affected the drying kinetics (DK) and thermo-environmental conditions of tomato slices. In this current investigation, three air speeds (1, 1.5, and 2 m/s) are used, as well as three slice thicknesses (ST) (4, 6, and 8 mm) and two SD, one of which is integrated with fixed collector motion (FCM) and another with SD tracking collector motion (TCM). The obtained results showed that the drying time (DT) isn’t significantly change with increasing air speeds from 1 to 2 m/s, this may be due to many reasons such as short DT, high temperature inside drying room, and little difference between the exanimated air speeds. When the ST is changed from 4 to 8 mm and maintaining constant air speeds, the DT for FCM and TCM rose by roughly 1.667 and 1.6 times, respectively. In addition, the drying coefficient of the TCM is higher than the FCM due to higher temperature. At 1.5 m/s air speed and 8 mm ST, the maximum values of moisture diffusivity (MD) are 7.15×10−10 and 9.30×10−10 m2/s for both FCM and TCM systems, respectively. During the study of DK, nine drying models and chose the best based on higher R2 and lower χ2 and RMSE are used. The findings of the DK analysis revealed that the modified two term II model fit the experimental data of various air speeds well when TF was dried using TCM and FCM systems at varying ST. These findings are based on recorded observations. Where the models’ R2 values varied from 0.98005 to 0.99942 for FCM system and varied from 0.99386 to 0.99976 for TCM system. Regarding environmental analysis, it is found that the CO2 mitigation per lifetime is ranged between 5334.9–6795.4 tons for FCM and 6305.7–6323.3 tons for TCM.

16 April 2024 in International Journal of Robotics and Control Systems
Verified
Journal Article
Open access
PDF file
AHAhmed Tawfik Hassan
Ahmed Tawfik Hassan
FBFahd A. Banakhr
Fahd A. Banakhr
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
ARAsmaa Fawzy Rashwan
Asmaa Fawzy Rashwan
MMMohamed Roshdy Moussa
Mohamed Roshdy Moussa
THTarek Hassan Mohamed Hassan
Tarek Hassan Mohamed Hassan
The negative impacts of microgrids (µGs) on the load frequency highlight the importance of implementing a robust, efficient, and adaptable controller to ensure stability. This work introduces an adaptive load frequency control (LFC) for an isolated µG that includes a PV system and electric vehicles (EVs), which have a significant impact on frequency. This control utilizes a combination of sine cosine optimization (SCO) and balloon effect identifier (BEI) algorithms. The controller presented in this work transforms the LFC process into an optimization problem that is highly compatible with various random situations encountered in the control process. The suggested control method is a novel approach by utilizing SCO+BEI for adaptive LFC application, resulting in a highly efficient response. The effectiveness of the proposed adaptive controller is assessed under the conditions of 17 MW variable load, system parameters uncertainties, and installed PV systems of 6 MW. MATLAB / Simulink package is rummage-sale as a digital test environment. According to simulation results, the proposed adaptive controller succeeds in regulating the frequency and power of an islanded µG. To measure the efficiency of the proposed control scheme, a comparison between other control techniques (such as adaptive controller using Jaya+BEI and classical integral controller) is done. The findings of the studied scenarios assured that the not compulsory control method using (SCO+BEI) has an obvious superiority over other control methods in terms of frequency solidity in case of random load instabilities and parameter uncertainties. Finally, it can be said that the proposed controller can better ensure the safe operation of the µGs.