Alexandr Jančárek

Dr. Alexandr Jančárek

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
MVMiroslava Vrbova
Miroslava Vrbova
PVP. Vrba
P. Vrba
AJAlexandr Jančárek
Alexandr Jančárek
MNMichal Nevrkla
Michal Nevrkla
NBN. A. Bobrova
N. A. Bobrova
PSPavel Sasorov
Pavel Sasorov
Magnetohydrodynamic simulations of plasma evolution in nitrogen-filled alumina capillaries, taking into account the ablation of capillary walls, are reported. Time dependences of the ionization state and populations of the selected energy levels of nitrogen ions are evaluated by the kinetic code FLYCHK, used as a postprocessor. Plasma properties, including the spectral characteristics, simulated according to experiments done in different laboratories, are in good agreement with experimental results. We made some estimations of the wall evaporation, showing that capillary wall ablation may play a significant role. We show that ablation of the capillary material is a serious barrier on the way to 13 nm nitrogen laser recombination pumping by the capillary pinch.

28 July 2018 in Materials
Verified
Journal Article
Open access
PDF file
PWPrzemyslaw Wachulak
Przemyslaw Wachulak
MDMartin Duda
Martin Duda
TFTomasz Fok
Tomasz Fok
ABAndrzej Bartnik
Andrzej Bartnik
ZWZhanshan Wang
Zhanshan Wang
HFHenryk Fiedorowicz
Henryk Fiedorowicz
We present a proof of principle experiment on single-shot near edge soft X-ray fine structure (NEXAFS) spectroscopy with the use of a laboratory laser-plasma light source. The source is based on a plasma created as a result of the interaction of a nanosecond laser pulse with a double stream gas puff target. The laser-plasma source was optimized for efficient soft X-ray (SXR) emission from the krypton/helium target in the wavelength range from 2 nm to 5 nm. This emission was used to acquire simultaneously emission and absorption spectra of soft X-ray light from the source and from the investigated sample using a grazing incidence grating spectrometer. NEXAFS measurements in a transmission mode revealed the spectral features near the carbon K-α absorption edge of thin polyethylene terephthalate (PET) film and L-ascorbic acid in a single-shot. From these features, the composition of the PET sample was successfully obtained. The NEXAFS spectrum of the L-ascorbic acid obtained in a single-shot exposure was also compared to the spectrum obtained a multi-shot exposure and to numerical simulations showing good agreement. In the paper, the detailed information about the source, the spectroscopy system, the absorption spectra measurements and the results of the studies are presented and discussed.

13 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TPTomas Parkman
Tomas Parkman
MNMichal Nevrkla
Michal Nevrkla
AJAlexandr Jančárek
Alexandr Jančárek
JTJana Turňová
Jana Turňová
DPDalibor Pánek
Dalibor Pánek
MVMiroslava Vrbova
Miroslava Vrbova
We present a design of a compact transmission water-window microscope based on the Z-pinching capillary discharge nitrogen plasma source. The microscope operates at wavelength of 2.88 nm (430 eV), and with its table-top dimensions provides an alternative to large-scale soft X-ray (SXR) microscope systems based on synchrotrons and free-electron lasers. The emitted soft X-ray radiation is filtered by a titanium foil and focused by an ellipsoidal condenser mirror into the sample plane. A Fresnel zone plate was used to create a transmission image of the sample onto a charge-coupled device (CCD) camera. To assess the resolution of the microscope, we imaged a standard sample-copper mesh. The spatial resolution of the microscope is 75 nm at half-pitch, calculated via a 10–90% intensity knife-edge test. The applicability of the microscope is demonstrated by the imaging of green algae-Desmodesmus communis. This paper describes the principle of capillary discharge source, design of the microscope, and experimental imaging results of Cu mesh and biological sample.

1 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MNMichal Nevrkla
Michal Nevrkla
JHJakub Hubner
Jakub Hubner
JŠJiří Šišma
Jiří Šišma
PVPavel Vrba
Pavel Vrba
MVMiroslava Vrbova
Miroslava Vrbova
AJAlexandr Jančárek
Alexandr Jančárek
Time dependencies of the electrical resistance and electron density evolution in the discharge in a tube, with nitrogen at different pressures, with a diameter of 9.2mm and a length of 10cm were studied. A current pulse with an amplitude of 500A and duration of 10μs has created the discharge in the tube. Instantaneous electron densities are estimated from the interference pattern in Mach–Zehnder interferometer using femtosecond Ti: sapphire laser beam. Laboratory results are compared with results of computer modelling by MHD computer codes NPINCH and ZSTAR. Time development of the discharge resistance according to experiment is measured and evaluated. Minimum measurable value of the electron density in the experiment is determined as 2×1015cm−3.

1 February 2025 in Physics of Plasmas
Verified
Journal Article
Open access
AJAlexandr Jančárek
Alexandr Jančárek
NBN. A. Bobrova
N. A. Bobrova
MNMichal Nevrkla
Michal Nevrkla
PSPavel Sasorov
Pavel Sasorov
JŠJiří Šišma
Jiří Šišma
MVMiroslava Vrbova
Miroslava Vrbova
The evolution of a nitrogen plasma discharge in a tube with an inner diameter of 9.2 mm, excited by a particular pulse shape, is studied to suppress ablation from the inner wall. Excitation is realized by two current pulses. The first one is a long pre-ionization pulse, which guarantees the stability of the plasma column, and the second one is a higher current pulse, which causes the detachment of the discharge plasma from the wall. The evolution of plasma in the tube is modeled using the magneto-hydrodynamic code NPINCH in two approximations: (1) non-ablative and (2) strongly ablative walls. The time dependences of the optical radiation power in the direction along the discharge tube axis are measured and compared with simulated experimental results in non-ablative and ablative approaches. Time dependence of the measured optical radiation emission corresponds to the non-ablative model. In the selected large diameter capillary, the development of the pinching plasma is not significantly affected by the ablation of the material from the capillary walls.