Magnetohydrodynamic simulations of plasma evolution in nitrogen-filled alumina capillaries, taking into account the ablation of capillary walls, are reported. Time dependences of the ionization state and populations of the selected energy levels of nitrogen ions are evaluated by the kinetic code FLYCHK, used as a postprocessor. Plasma properties, including the spectral characteristics, simulated according to experiments done in different laboratories, are in good agreement with experimental results. We made some estimations of the wall evaporation, showing that capillary wall ablation may play a significant role. We show that ablation of the capillary material is a serious barrier on the way to 13 nm nitrogen laser recombination pumping by the capillary pinch.
We present a proof of principle experiment on single-shot near edge soft X-ray fine structure (NEXAFS) spectroscopy with the use of a laboratory laser-plasma light source. The source is based on a plasma created as a result of the interaction of a nanosecond laser pulse with a double stream gas puff target. The laser-plasma source was optimized for efficient soft X-ray (SXR) emission from the krypton/helium target in the wavelength range from 2 nm to 5 nm. This emission was used to acquire simultaneously emission and absorption spectra of soft X-ray light from the source and from the investigated sample using a grazing incidence grating spectrometer. NEXAFS measurements in a transmission mode revealed the spectral features near the carbon K-α absorption edge of thin polyethylene terephthalate (PET) film and L-ascorbic acid in a single-shot. From these features, the composition of the PET sample was successfully obtained. The NEXAFS spectrum of the L-ascorbic acid obtained in a single-shot exposure was also compared to the spectrum obtained a multi-shot exposure and to numerical simulations showing good agreement. In the paper, the detailed information about the source, the spectroscopy system, the absorption spectra measurements and the results of the studies are presented and discussed.
We present a design of a compact transmission water-window microscope based on the Z-pinching capillary discharge nitrogen plasma source. The microscope operates at wavelength of 2.88 nm (430 eV), and with its table-top dimensions provides an alternative to large-scale soft X-ray (SXR) microscope systems based on synchrotrons and free-electron lasers. The emitted soft X-ray radiation is filtered by a titanium foil and focused by an ellipsoidal condenser mirror into the sample plane. A Fresnel zone plate was used to create a transmission image of the sample onto a charge-coupled device (CCD) camera. To assess the resolution of the microscope, we imaged a standard sample-copper mesh. The spatial resolution of the microscope is 75 nm at half-pitch, calculated via a 10–90% intensity knife-edge test. The applicability of the microscope is demonstrated by the imaging of green algae-Desmodesmus communis. This paper describes the principle of capillary discharge source, design of the microscope, and experimental imaging results of Cu mesh and biological sample.
Time dependencies of the electrical resistance and electron density evolution in the discharge in a tube, with nitrogen at different pressures, with a diameter of and a length of were studied. A current pulse with an amplitude of and duration of has created the discharge in the tube. Instantaneous electron densities are estimated from the interference pattern in Mach–Zehnder interferometer using femtosecond Ti: sapphire laser beam. Laboratory results are compared with results of computer modelling by MHD computer codes NPINCH and ZSTAR. Time development of the discharge resistance according to experiment is measured and evaluated. Minimum measurable value of the electron density in the experiment is determined as .
The evolution of a nitrogen plasma discharge in a tube with an inner diameter of 9.2 mm, excited by a particular pulse shape, is studied to suppress ablation from the inner wall. Excitation is realized by two current pulses. The first one is a long pre-ionization pulse, which guarantees the stability of the plasma column, and the second one is a higher current pulse, which causes the detachment of the discharge plasma from the wall. The evolution of plasma in the tube is modeled using the magneto-hydrodynamic code NPINCH in two approximations: (1) non-ablative and (2) strongly ablative walls. The time dependences of the optical radiation power in the direction along the discharge tube axis are measured and compared with simulated experimental results in non-ablative and ablative approaches. Time dependence of the measured optical radiation emission corresponds to the non-ablative model. In the selected large diameter capillary, the development of the pinching plasma is not significantly affected by the ablation of the material from the capillary walls.