Low-density meter-scale plasma waveguides produced in meter-scale supersonic gas jets have paved the way for recent demonstrations of all-optical multi-gigaelectronvolt laser wakefield acceleration (LWFA). This paper reviews recent advances by the University of Maryland, which have enabled these results, focusing on the development of elongated supersonic gas jets up to ∼1 m in length, experimental and simulation studies of plasma waveguide formation, and a new three-stage model for relativistic pulse propagation dynamics in these waveguides. We also present results from recent LWFA experiments conducted at the Laboratory for Advanced Lasers and Extreme Photonics at Colorado State University demonstrating high charge, low divergence electron bunches to ∼10 GeV, with laser-to-electron beam efficiency of at least ∼30%.
29 April 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Time dependencies of the electrical resistance and electron density evolution in the discharge in a tube, with nitrogen at different pressures, with a diameter of and a length of were studied. A current pulse with an amplitude of and duration of has created the discharge in the tube. Instantaneous electron densities are estimated from the interference pattern in Mach–Zehnder interferometer using femtosecond Ti: sapphire laser beam. Laboratory results are compared with results of computer modelling by MHD computer codes NPINCH and ZSTAR. Time development of the discharge resistance according to experiment is measured and evaluated. Minimum measurable value of the electron density in the experiment is determined as .
We demonstrate a method to characterize the beam energy, transverse profile, charge, and dose of a pulsed electron beam generated by a 1 kHz TW laser-plasma accelerator. The method is based on imaging with a scintillating screen in an inhomogeneous, orthogonal magnetic field produced by a wide-gap magnetic dipole. Numerical simulations were developed to reconstruct the electron beam parameters accurately. The method has been experimentally verified and calibrated using a medical LINAC. The energy measurement accuracy in the 6–20 MeV range is proven to be better than 10%. The radiation dose has been calibrated by a water-equivalent phantom, RW3, showing a linear response of the method within 2% in the 0.05–0.5 mGy/pulse range.
The evolution of a nitrogen plasma discharge in a tube with an inner diameter of 9.2 mm, excited by a particular pulse shape, is studied to suppress ablation from the inner wall. Excitation is realized by two current pulses. The first one is a long pre-ionization pulse, which guarantees the stability of the plasma column, and the second one is a higher current pulse, which causes the detachment of the discharge plasma from the wall. The evolution of plasma in the tube is modeled using the magneto-hydrodynamic code NPINCH in two approximations: (1) non-ablative and (2) strongly ablative walls. The time dependences of the optical radiation power in the direction along the discharge tube axis are measured and compared with simulated experimental results in non-ablative and ablative approaches. Time dependence of the measured optical radiation emission corresponds to the non-ablative model. In the selected large diameter capillary, the development of the pinching plasma is not significantly affected by the ablation of the material from the capillary walls.
12 May 2026 in High Power Laser Science and Engineering
We present recent results on high-power guiding and laser wakefield acceleration in the ELectron Beam Accelerator (ELBA) beamline at ELI Beamlines, using the L3-HAPLS laser system (13 J, 30 fs, 0.2 Hz). By employing self-waveguiding in a 20 cm plasma channel in helium, we achieved stable acceleration of electron beams to energies of approximately 5 GeV. A novel all-reflective optical setup, including an off-axis reflective axicon, enabled efficient acceleration at 0.2 Hz and guiding at repetition rates up to 3.3 Hz. This compact single laser, single-compressor implementation of plasma channels for electron acceleration stabilizes electron pointing and enhances energy gain without requiring modifications to the laser system, paving the way for broader adoption of the technology across user facilities.