Despite the remarkable development of the medical industry in the current era, herbal products with therapeutic potentials arise as attractive alternative treatments. Consequently, Chios mastiha, a natural, aromatic resin obtained from the trunk and brunches of the mastic tree, has recently gained increasing scientific interest due to its multiple beneficial actions. Chios mastiha is being exclusively produced on the southern part of Chios, a Greek island situated in the northern Aegean Sea, and its therapeutic properties have been known since Greek antiquity. There is now substantial evidence to suggest that mastiha demonstrates a plethora of favorable effects, mainly attributed to the anti-inflammatory and anti-oxidative properties of its components. The main use of mastiha nowadays, however, is for the production of natural chewing gum, although an approval by the European Medicines Agency for mild dyspeptic disorders and for inflammations of the skin has been given. The aim of this article is to summarize the most important data about the therapeutic actions of Chios mastiha and discuss future fields for its medical application.
Pulsed field ablation (PFA) is an innovative technology recently adopted for the treatment of atrial fibrillation (AF). Preclinical and clinical studies have reported a remarkable safety profile, as a result of its tissue specific effect targeting cardiomyocytes and sparing adjacent tissues. Single-shot pentaspline system was the first PFA device to receive regulatory approval. We performed a meta-analysis to compare the efficacy and safety of PFA with the single-shot pentaspline system versus currently available 2nd/3rd/4th generation Cryoballoon technologies (CRYO). We systematically searched electronic databases for studies focusing on AF ablation employing the PFA single-shot pentaspline system or 2nd/3rd/4th generation CRYO technologies. The primary endpoints were acute procedural success assessed on a vein and patient basis. Safety endpoints included overall periprocedural complications and major periprocedural complications. We also compared procedural, fluoroscopy times, and freedom from atrial tachyarrhythmias (ATs) at follow-up (secondary endpoints). Twenty and 70 studies were included for PFA and CRYO, respectively. PFA demonstrated greater acute procedural success on a vein basis (99.9% vs 99.1%; p<0.001), as well as per patient (99.5% vs 98.4%; p<0.001). PFA yielded lower overall periprocedural complications (3.1% vs 5.6%; p<0.001), shorter procedural time (75.9 min vs 105.6 min; p<0.001) and fluoroscopy time (14.2 min vs 18.9 min; p<0.001) compared to CRYO. No differences were found for major periprocedural complications (1.2% vs 1.0%; p=0.46) and freedom from ATs at 1 year (82.3% vs 80.3%; Log-rank p= 0.61). PFA contributed to higher acute procedural success, and safety compared to CRYO. No statistically significant differences in AT recurrence at 1-year follow-up were observed.