ZUQUAN WU

Dr. ZUQUAN WU

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Analytica Chimica Acta
Verified
Journal Article
Closed access
ZWZUQUAN WU
ZUQUAN WU
SZShibu Zhu
Shibu Zhu
XDXiu-cheng Dong
Xiu-cheng Dong
YYYao Yao
Yao Yao
YGYifan Guo
Yifan Guo
Zuowan ZhouZuowan Zhou
Zuowan Zhou

11 November 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ZWZUQUAN WU
ZUQUAN WU
LLLei Liang
Lei Liang
SZShibu Zhu
Shibu Zhu
YGYifan Guo
Yifan Guo
YYYao Yao
Yao Yao
Zuowan ZhouZuowan Zhou
Zuowan Zhou
Recently, as a two-dimensional (2D) material, black phosphorous (BP) has attracted more and more attention. However, few efforts have been made to investigate the BP/polyaniline (PANI) nanocomposite for ammonia (NH3) gas sensors. In this work, the BP/PANI nanocomposite as a novel sensing material for NH3 detection, has been synthesized via in situ chemical oxidative polymerization, which is then fabricated onto the interdigitated transducer (IDTs). The electrical properties of the BP/PANI thin film are studied in a large detection range from 1 to 4000 ppm, such as conduction mechanism, response, reproducibility, and selectivity. The experimental result indicates that the BP/PANI sensor shows higher sensitivity and larger detection range than that of PANI. The BP added into PANI, that may enlarge the specific surface area, obtain the special trough structure for gas channels, and form the p–π conjugation system and p–p isotype heterojunctions, which are beneficial to increase the response of BP/PANI to NH3 sensing. Meanwhile, in order to support the discussion result, the structure and morphology of the BP/PANI are respectively measured by Fourier transform infrared spectroscopy (FTIR), ultraviolet-visible spectroscopy (UV−vis), transmission electron microscopy (TEM), and field emissions scanning electron microscopy (SEM). Moreover, the sensor shows good reproducibility, and fast response and recovery behavior, on NH3 sensing. In addition, this route may offer the advantages of an NH3 sensor, which are of simple structure, low cost, easy to assemble, and operate at room temperature.

10 December 2022 in International Journal of Control, Automation, and Systems
Verified
Journal Article
Closed access
PDF file
YYYong Yang
Yong Yang
XDXiu-cheng Dong
Xiu-cheng Dong
ZWZUQUAN WU
ZUQUAN WU
XLXiu Liu
Xiu Liu
DHDeqing Huang
Deqing Huang

26 August 2024 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
JSJianwen Song
Jianwen Song
LLLei Liang
Lei Liang
XYXiao Yong
Xiao Yong
XCXinpeng Chen
Xinpeng Chen
SZShibu Zhu
Shibu Zhu
ZWZUQUAN WU
ZUQUAN WU
In this article, molybdenum disulfide (MoS $_{\text{2}}$ )/ cellulose nanocrystal (CNC) nanocomposites are coated on silver electrodes of the quartz crystal microbalance (QCM) by the drop-coating method for humidity sensing. The performance of QCM humidity sensors of MoS $_{\text{2}}$ , CNC, and MoS $_{\text{2}}$ /CNC thin films is investigated in the relative humidity (RH) range of 11.31%–97.59%. The experimental results reveal that MoS $_{\text{2}}$ /CNC humidity sensor has high sensitivity (ca. 36.03 Hz/%RH), which is higher than CNC (ca. 1.25 times) and MoS $_{\text{2}}$ (ca. 2.5 times). Meanwhile, the sensor has excellent repeatability, high stability, and low humidity hysteresis (ca. 3.3%RH). Moreover, the Langmuir isotherm adsorption model is also used to investigate the humidity-sensitive mechanism of MoS $_{\text{2}}$ /CNC humidity sensors. In addition, MoS $_{\text{2}}$ /CNC humidity sensor can be well applicable for respiration monitoring which has good application prospect.

17 August 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
HGHuihui Guo
Huihui Guo
YLYuhang Li
Yuhang Li
TLTingting Liu
Tingting Liu
ZWZUQUAN WU
ZUQUAN WU
Conductive graphene polymer composites are considered promising functional materials in gas detection, strain detection, metal corrosion prevention, and electromagnetic wave absorption, owing to their good flexibility, lightweight, and adjustable conductivity. The internal defects or external damages of composite films will seriously affect the electrical and functional properties of the materials. Based on the conductive network inside the conductive polymer film and the self-inductance to ultrasonic wave, the defect self-monitoring system of the conductive polymer film is designed and optimized in this work. The self-damage detection system is composed of an electrode array, excitation source, resistance signal acquisition and processing circuit, and damage display. Aiming at different scenarios, the improved interdigital structure transducer for sensors and damage detection device for coating film with a large area are presented and optimized respectively. Meanwhile, the damage location algorithm based on time difference measurement and kernel density estimation algorithm is also optimized. The multiple damage detection is realized by a device with a 4 × 8 electrode array, and the relative error of damage area with 1 mm × 1 mm is less than 5%, and the lower detection limits of damage size are 0.3 mm × 0.3 mm.

12 December 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WZWeihang Zhang
Weihang Zhang
XYXiao Yong
Xiao Yong
QZQing Zhou
Qing Zhou
XCXingpeng Chen
Xingpeng Chen
ZWZUQUAN WU
ZUQUAN WU
In this paper, a novel Nafion/cellulose nanocrystal (CNC) nanocomposite was synthesized by mixing method, which has been fabricated onto Quartz Crystal Microbalance (QCM) as humidity sensor via drop-coating method. The humidity sensitive characteristic of the QCM sensor is investigated in various relative humidity (RH). The experimental result indicates that the Nafion/CNC exhibits excellent sensitivity, slight humidity hysteresis (ca. 4.3%), good repeatability and high stability. Among them, the sensitivity of Nafion/CNC (ca. 48.43 Hz/RH) is higher than that of CNC (ca. 1.31 times) and Nafion (ca. 1.43 times). The humidity sensitive mechanism of Nafion/CNC is also discussed by the Langmuir isothermal adsorption model. Meanwhile, the structure and morphology of the synthesized products are analyzed by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and transmission electron microscopy (TEM), respectively. Additionally, the Nafion/CNC humidity sensor has been applied for respiration monitoring, demonstrating good potential for application.