Omar Hammad Ali

Dr. Omar Hammad Ali

Bruno Kessler Foundation (FBK, Trento Italy)
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2021 in Instruments
Verified
Journal Article
Open access
PDF file
MMMauro Mauro Menichelli
Mauro Mauro Menichelli
MBMarco Bizzarri
Marco Bizzarri
MBMaurizio Boscardin
Maurizio Boscardin
MCMirco Caprai
Mirco Caprai
Anna Paola CaricatoAnna Paola Caricato
Anna Paola Caricato
Nicolas WyrschNicolas Wyrsch
Nicolas Wyrsch
Hydrogenated amorphous silicon (a-Si:H) can be produced by plasma-enhanced chemical vapor deposition (PECVD) of SiH4 (silane) mixed with hydrogen. The resulting material shows outstanding radiation hardness properties and can be deposited on a wide variety of substrates. Devices employing a-Si:H technologies have been used to detect many different kinds of radiation, namely, minimum ionizing particles (MIPs), X-rays, neutrons, and ions, as well as low-energy protons and alphas. However, the detection of MIPs using planar a-Si:H diodes has proven difficult due to their unsatisfactory S/N ratio arising from a combination of high leakage current, high capacitance, and limited charge collection efficiency (50% at best for a 30 µm planar diode). To overcome these limitations, the 3D-SiAm collaboration proposes employing a 3D detector geometry. The use of vertical electrodes allows for a small collection distance to be maintained while preserving a large detector thickness for charge generation. The depletion voltage in this configuration can be kept below 400 V with a consequent reduction in the leakage current. In this paper, following a detailed description of the fabrication process, the results of the tests performed on the planar p-i-n structures made with ion implantation of the dopants and with carrier selective contacts are illustrated.

20 November 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Giada MarchiGiada Marchi
Giada Marchi
VMViviana Mulloni
Viviana Mulloni
OAOmar Hammad Ali
Omar Hammad Ali
Leandro LorenzelliLeandro Lorenzelli
Leandro Lorenzelli
Massimo DonelliMassimo Donelli
Massimo Donelli
This study is supposed to introduce a valid strategy for increasing the sensitivity of chipless radio frequency identification (RFID) encoders. The idea is to properly select the dielectric substrate in order to enhance the contribution of the sensitive layer and to maximize the frequency shift of the resonance peak. The specific case of a chipless sensor suitable for the detection of humidity in low-humidity regimes will be investigated both with numerical and experimental tests.

25 October 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
OVO.A. Marti Villarreal
O.A. Marti Villarreal
AVanna vignati
anna vignati
SGS. Giordanengo
S. Giordanengo
MAM. Abujami
M. Abujami
GBGiacomo Borghi
Giacomo Borghi
MPMarco Pullia
Marco Pullia

17 December 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
Ashish BishtAshish Bisht
Ashish Bisht
GBGiacomo Borghi
Giacomo Borghi
MBMaurizio Boscardin
Maurizio Boscardin
MVMatteo Centis Vignali
Matteo Centis Vignali
FFFrancesco Ficorella
Francesco Ficorella
GPGiovanni Paternoster
Giovanni Paternoster

31 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MAMaria del mar Carulla Areste
Maria del mar Carulla Areste
RBRebecca Barten
Rebecca Barten
FBFilippo Baruffaldi
Filippo Baruffaldi
ABAnna Bergamaschi
Anna Bergamaschi
GBGiacomo Borghi
Giacomo Borghi
JZJiaguo Zhang
Jiaguo Zhang
Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement.

29 November 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
VMVincenzo Monaco
Vincenzo Monaco
OAOmar Hammad Ali
Omar Hammad Ali
DBDavide Bersani
Davide Bersani
MAMohammed Abujami
Mohammed Abujami
MBMaurizio Boscardin
Maurizio Boscardin
Roberto SacchiRoberto Sacchi
Roberto Sacchi
Objective . The performance of silicon detectors with moderate internal gain, named low-gain avalanche diodes (LGADs), was studied to investigate their capability to discriminate and count single beam particles at high fluxes, in view of future applications for beam characterization and on-line beam monitoring in proton therapy. Approach . Dedicated LGAD detectors with an active thickness of 55 μ m and segmented in 2 mm 2 strips were characterized at two Italian proton-therapy facilities, CNAO in Pavia and the Proton Therapy Center of Trento, with proton beams provided by a synchrotron and a cyclotron, respectively. Signals from single beam particles were discriminated against a threshold and counted. The number of proton pulses for fixed energies and different particle fluxes was compared with the charge collected by a compact ionization chamber, to infer the input particle rates. Main results . The counting inefficiency due to the overlap of nearby signals was less than 1% up to particle rates in one strip of 1 MHz, corresponding to a mean fluence rate on the strip of about 5 × 10 7 p/(cm 2 ·s). Count-loss correction algorithms based on the logic combination of signals from two neighboring strips allow to extend the maximum counting rate by one order of magnitude. The same algorithms give additional information on the fine time structure of the beam. Significance . The direct counting of the number of beam protons with segmented silicon detectors allows to overcome some limitations of gas detectors typically employed for beam characterization and beam monitoring in particle therapy, providing faster response times, higher sensitivity, and independence of the counts from the particle energy.