Raluca Maria Vieriu

Dr. Raluca Maria Vieriu

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2024 in Materials
Verified
Journal Article
Open access
PDF file
NONicolae Daniel Olteanu
Nicolae Daniel Olteanu
Ionut TaraboantaIonut Taraboanta
Ionut Taraboanta
Tinela PanaiteTinela Panaite
Tinela Panaite
CBCarina Balcoş
Carina Balcoş
SRSorana Nicoleta Rosu
Sorana Nicoleta Rosu
Irina nicoleta ZetuIrina nicoleta Zetu
Irina nicoleta Zetu
This study aimed to compare the color changes in two different orthodontic clear aligner systems after submersion in various beverages for 14 days. The tested aligner systems were Taglus Premium made of polyethylene terephthalate glycol (the TAG group) and CA® Prodin+ made of a transparent copolyester and a thermoplastic elastomer (the PRO group). A total of 56 samples were firstly divided into two groups according to the tested system—TAG and PRO. Each group was subsequently divided in four subgroups according to immersion solution: A—artificial saliva, B—cola, C—coffee, D—red wine. Color measurements were performed on Days 1, 7 and 14 using a portable colorimeter and the CIE L*a*b* system. The obtained results showed significant color changes in both materials when exposed to coffee and red wine (p > 0.05). Samples in the PRO group showed a greater susceptibility to discoloration (higher ΔE values) when compared to the TAG group after submersion in cola (p = 0.025), coffee (p = 0.005) and red wine (p = 0.041) solutions. Statistical analysis revealed that all of the color parameters ΔL*, Δa*, Δb* and ΔE of both tested materials were affected by submersion in coffee solution for 14 days. In conclusion, the CA® Pro+ aligner system is more prone to staining compared to the Taglus material after submersion for 14 days in cola, coffee and red wine solutions. Submersion for 14 days in coffee solution alters all of the color parameters (ΔL, Δa, Δb and ΔE) of both tested aligner materials.

11 April 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Tinela PanaiteTinela Panaite
Tinela Panaite
CSCARMEN SAVIN
CARMEN SAVIN
NONicolae Daniel Olteanu
Nicolae Daniel Olteanu
NKNikolaos Karvelas
Nikolaos Karvelas
CRCristian Romanec
Cristian Romanec
Irina nicoleta ZetuIrina nicoleta Zetu
Irina nicoleta Zetu
Orthodontic mini-implants are devices used for anchorage in various orthodontic treatments. We conducted a pilot study which aimed to observe preliminary trends regarding the impact of heat treatment on the elastic modulus of Ti6Al4V alloy and stainless steel 316L mini-implants. The initial phase involved testing the impact of heat treatment on the mechanical properties of Ti6Al4V alloy and stainless steel 316L mini-implants. Material and methods: Ten self-drilling mini-implants sourced from two distinct manufacturers (Jeil Medical Corporation® and Leone®) with dimensions of 2.0 mm diameter and 10 mm length were tested. They were separated into two material groups: Ti6Al4V and 316L. Using the CETRUMT-2 microtribometer equipment, indentation testing was conducted employing a diamond-tipped Rockwell penetrator at a constant force of 4.5 N. Results: Slight differences were observed in the elastic modulus of the Ti6Al4V alloy (103.99 GPa) and stainless steel 316L (203.20 GPa) compared to natural bone. The higher elastic moduli of these materials indicate that they are stiffer, which could potentially lead to stress-shielding phenomena and bone resorption. Heat treatment resulted in significant changes in mechanical properties, including elastic modulus reductions of approximately 26.14% for Ti6Al4V and 24.82% for 316L, impacting their performance in orthodontic applications. Conclusion: Understanding the effects of heat treatment on these alloys is crucial for optimizing their biomechanical compatibility and longevity in orthodontic treatment. To fully evaluate the effects of heat treatment on mini-implants and to refine their design and efficacy in clinical practice, further research is needed.

OȚOana Țănculescu
Oana Țănculescu
AAAlina-Mihaela Apostu
Alina-Mihaela Apostu
ADAdrian Doloca
Adrian Doloca
SSSorina Mihaela Solomon
Sorina Mihaela Solomon
DPDiana Antonela Diaconu Popa
Diana Antonela Diaconu Popa
Catalina Iulia SaveanuCatalina Iulia Saveanu
Catalina Iulia Saveanu
The COVID-19 pandemic has forced the transfer of traditional on-site educational activities to the online environment. This study aimed to evaluate the perception and acceptance of remote learning among fixed prosthodontic students attending the Faculty of Dental Medicine of “Grigore T. Popa” University of Medicine and Pharmacy in Iasi, Romania, and to analyze the feedback regarding their experience with the new online methods, the perceived quality thereof and suggestions for improvement. An observational cross-sectional, online study based on 22 questions was conducted with 259 students. The general opinion of online education was good or very good (40.15%); regarding its efficiency, 28.57% found it efficient while 34.36% found it inefficient or very inefficient; regarding the pleasure of learning online, 45.95% of students enjoyed online learning, while 36.64% did not enjoy it. The problem that was most cited by respondents was that of keeping all students motivated and involved (65.6%). Sixty-two percent of the respondents believe that online dental education should not exist, or just to a small extent, a result justified by the practical nature of the profession. The general opinion was that health risks should be managed and mitigated by using a hybrid system that would allow students to do on-site clinical training with direct contact with patients.

5 February 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Tinela PanaiteTinela Panaite
Tinela Panaite
CSCARMEN SAVIN
CARMEN SAVIN
NONicolae Daniel Olteanu
Nicolae Daniel Olteanu
CRCristian Romanec
Cristian Romanec
RVRaluca Maria Vieriu
Raluca Maria Vieriu
Irina nicoleta ZetuIrina nicoleta Zetu
Irina nicoleta Zetu
Objective: This study aims to investigate the mechanical behavior of titanium (Ti6Al4V) mini-implants (MIs) under varying orthodontic forces using finite element analysis (FEA) and to evaluate their performance and durability under realistic clinical conditions. Optimal orthodontic forces significantly influence the structural integrity and functional longevity of MIs while minimizing adverse effects on surrounding bone tissues. Materials and Methods: A commercially available MI (diameter: 2.0 mm, length: 12 mm) was modeled using FEA. The mandible geometry was obtained using computed tomography (CT) scanning, reconstructed in 3D using SpaceClaim software 2023.1, and discretized into 10-node tetrahedral elements in ANSYS Workbench. Material properties were assigned based on the existing literature, and the implant–bone interaction was simulated using a nonlinear frictional contact model. Orthodontic forces of 2 N and 10 N, inclined at 30°, were applied to simulate clinical loading conditions. Total displacement, von Mises stresses, equivalent strains, fatigue life, and safety factors were analyzed to assess the implant’s mechanical performance. Results: At 2 N, the MI demonstrated minimal displacement (0.0328 mm) and sustained approximately 445,000 cycles under safe fatigue loading conditions, with a safety factor of 4.8369. At 10 N, the implant’s lifespan was drastically reduced to 1546 cycles, with significantly elevated stress (6.468 × 105 MPa) and strain concentrations, indicating heightened risks of mechanical failure and bone damage. The findings revealed the critical threshold beyond which orthodontic forces compromise implant stability and peri-implant bone health. Conclusions: This study confirms that maintaining orthodontic forces within an optimal range, approximately 2 N, is essential to prolong MI lifespan and preserve bone integrity. Excessive forces, such as 10 N, lead to a rapid decline in durability and increased risks of failure, emphasizing the need for calibrated force application in clinical practice. These insights provide valuable guidance for enhancing MI performance and optimizing orthodontic treatment outcomes.

9 April 2025 in Romanian Journal of Oral Rehabilitation
Verified
Journal Article
Open access
Tinela PanaiteTinela Panaite
Tinela Panaite
CRCristian Liviu Romanec
Cristian Liviu Romanec
MIMihnea Iacob
Mihnea Iacob
RVRaluca Maria Vieriu
Raluca Maria Vieriu
ACAlice Chehab
Alice Chehab
CSCarmen Savin
Carmen Savin
This study investigates the structural characterization of orthodontic mini-implants made from Ti6Al4V alloy and 316L stainless steel before and after heat treatment using X-ray diffraction (XRD). The analysis was performed using a PANalytical X’Pert PRO MPD diffractometer to evaluate the crystallographic structure, phase composition, and changes induced by thermal processing. Diffraction patterns revealed characteristic peaks corresponding to the α and β phases in Ti6Al4V and specific crystallographic planes in 316L stainless steel.For Ti6Al4V, the results indicated consistent crystallographic structures before and after heat treatment, with prominent peaks at approximately 30.6215° 2Theta. However, subtle modifications in peak intensity and width suggested alterations in microstructure. Similarly, heat-treated 316L samples exhibited changes in peak positions, intensities, and widths, reflecting shifts in lattice spacing and crystalline phases.The findings demonstrate that heat treatment influences the structural properties of both materials, optimizing their performance for clinical applications. The study underscores the utility of XRD in evaluating the crystallinity, phase composition, and microstructural consistency of mini-implants, providing valuable insights for enhancing their design, stability, and reliability in orthodontic treatments.

9 April 2025 in Romanian Journal of Oral Rehabilitation
Verified
Journal Article
Open access
CRCristian Liviu Romanec
Cristian Liviu Romanec
Tinela PanaiteTinela Panaite
Tinela Panaite
EREmma Alexandra Rotaru
Emma Alexandra Rotaru
APAlexandra Lorina Platon
Alexandra Lorina Platon
CSCarmen Savin
Carmen Savin
Irina nicoleta ZetuIrina nicoleta Zetu
Irina nicoleta Zetu
Background: Mouth breathing significantly impacts orofacial development and orthodontic outcomes, contributing to malocclusion, narrow palates, and altered facial growth. This systematic review explores its causes, effects, and treatment strategies in orthodontics.Materials and Methods: A comprehensive search was conducted in PubMed, Google Scholar, and PMC databases for studies published between 2000 and 2024. Keywords included "mouth breathing and orthodontics" and "impact of mouth breathing on malocclusion." Inclusion criteria focused on studies examining skeletal and oral development, orthodontic interventions for mouth breathers, and clinical trials. Data extraction captured sample size, study design, and outcomes.Results: Chronic mouth breathing, caused by nasal obstruction, adenoid hypertrophy, craniofacial anomalies, and habitual behaviors, leads to malocclusion, open bites, and long face syndrome. Myofunctional therapy, palatal expansion, and orthodontic appliances effectively address these issues, while surgical interventions like adenotonsillectomy treat underlying causes. Early intervention is critical to mitigate long-term dental and facial consequences.Conclusion: Mouth breathing profoundly affects oral and facial development, emphasizing the need for early diagnosis and multidisciplinary treatment combining orthodontic care, therapy, and surgical correction. Further research is necessary to refine treatment strategies and improve outcomes for mouth-breathing patients.