Tinela Panaite

Dr. Tinela Panaite

Orthodontics and Dento Facial Orthopedics, University of Medicine and Pharmacy Grigore T Popa iasi România, Iaşi, Romania
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2024 in Materials
Verified
Journal Article
Open access
PDF file
NONicolae Daniel Olteanu
Nicolae Daniel Olteanu
Ionut TaraboantaIonut Taraboanta
Ionut Taraboanta
Tinela PanaiteTinela Panaite
Tinela Panaite
CBCarina Balcoş
Carina Balcoş
SRSorana Nicoleta Rosu
Sorana Nicoleta Rosu
Irina nicoleta ZetuIrina nicoleta Zetu
Irina nicoleta Zetu
This study aimed to compare the color changes in two different orthodontic clear aligner systems after submersion in various beverages for 14 days. The tested aligner systems were Taglus Premium made of polyethylene terephthalate glycol (the TAG group) and CA® Prodin+ made of a transparent copolyester and a thermoplastic elastomer (the PRO group). A total of 56 samples were firstly divided into two groups according to the tested system—TAG and PRO. Each group was subsequently divided in four subgroups according to immersion solution: A—artificial saliva, B—cola, C—coffee, D—red wine. Color measurements were performed on Days 1, 7 and 14 using a portable colorimeter and the CIE L*a*b* system. The obtained results showed significant color changes in both materials when exposed to coffee and red wine (p > 0.05). Samples in the PRO group showed a greater susceptibility to discoloration (higher ΔE values) when compared to the TAG group after submersion in cola (p = 0.025), coffee (p = 0.005) and red wine (p = 0.041) solutions. Statistical analysis revealed that all of the color parameters ΔL*, Δa*, Δb* and ΔE of both tested materials were affected by submersion in coffee solution for 14 days. In conclusion, the CA® Pro+ aligner system is more prone to staining compared to the Taglus material after submersion for 14 days in cola, coffee and red wine solutions. Submersion for 14 days in coffee solution alters all of the color parameters (ΔL, Δa, Δb and ΔE) of both tested aligner materials.

23 July 2025 in Medicina
Verified
Journal Article
Open access
PDF file
Tinela PanaiteTinela Panaite
Tinela Panaite
CRCristian Romanec
Cristian Romanec
AAAdina Oana Armencia
Adina Oana Armencia
CBCarina Balcoş
Carina Balcoş
CSCARMEN SAVIN
CARMEN SAVIN
ASAna Sîrghie
Ana Sîrghie
Background and Objectives: Orthodontic treatment aims to enhance dental aesthetics and function, yet many patients report dissatisfaction. This study was designed with the following objectives: To assess overall patient satisfaction during active orthodontic treatment; to identify key psychosocial and clinical predictors of satisfaction, including self-confidence, social experiences, and cost perception; to evaluate the impact of orthodontist–patient communication on satisfaction and perceived treatment outcomes; to explore the relationship between aesthetic improvement and willingness to undergo treatment again. Materials and Methods: A cross-sectional survey was conducted using structured questionnaires to assess satisfaction, pain perception, treatment expectations, and communication quality. Statistical analyses, including correlations and regression models, were used to identify predictors of satisfaction. The study included 450 orthodontic patients from the north-eastern region of Romania, undergoing active treatment at the time of data collection. Results: The strongest predictor of satisfaction was improved self-confidence and smile aesthetics (r = 0.62). Effective communication with orthodontists significantly increased satisfaction (r = 0.58, p = 0.002), while perceived high costs had a negative impact (r = −0.41). Pain and discomfort were common, with 90% of patients experiencing treatment-related pain, leading to reduced compliance. Social embarrassment due to braces also contributed to dissatisfaction (r = −0.47). Conclusions: Patient satisfaction with orthodontic treatment is primarily influenced by aesthetic improvements and effective communication. While enhanced smile perception boosts confidence, financial concerns and social discomfort may negatively affect the overall experience. Improving accessibility to treatment and providing comprehensive patient support are essential for optimizing patient satisfaction.

11 April 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Tinela PanaiteTinela Panaite
Tinela Panaite
CSCARMEN SAVIN
CARMEN SAVIN
NONicolae Daniel Olteanu
Nicolae Daniel Olteanu
NKNikolaos Karvelas
Nikolaos Karvelas
CRCristian Romanec
Cristian Romanec
Irina nicoleta ZetuIrina nicoleta Zetu
Irina nicoleta Zetu
Orthodontic mini-implants are devices used for anchorage in various orthodontic treatments. We conducted a pilot study which aimed to observe preliminary trends regarding the impact of heat treatment on the elastic modulus of Ti6Al4V alloy and stainless steel 316L mini-implants. The initial phase involved testing the impact of heat treatment on the mechanical properties of Ti6Al4V alloy and stainless steel 316L mini-implants. Material and methods: Ten self-drilling mini-implants sourced from two distinct manufacturers (Jeil Medical Corporation® and Leone®) with dimensions of 2.0 mm diameter and 10 mm length were tested. They were separated into two material groups: Ti6Al4V and 316L. Using the CETRUMT-2 microtribometer equipment, indentation testing was conducted employing a diamond-tipped Rockwell penetrator at a constant force of 4.5 N. Results: Slight differences were observed in the elastic modulus of the Ti6Al4V alloy (103.99 GPa) and stainless steel 316L (203.20 GPa) compared to natural bone. The higher elastic moduli of these materials indicate that they are stiffer, which could potentially lead to stress-shielding phenomena and bone resorption. Heat treatment resulted in significant changes in mechanical properties, including elastic modulus reductions of approximately 26.14% for Ti6Al4V and 24.82% for 316L, impacting their performance in orthodontic applications. Conclusion: Understanding the effects of heat treatment on these alloys is crucial for optimizing their biomechanical compatibility and longevity in orthodontic treatment. To fully evaluate the effects of heat treatment on mini-implants and to refine their design and efficacy in clinical practice, further research is needed.

7 January 2025 in Frontiers in Oral Health
Verified
Journal Article
Open access
PDF file
Tinela PanaiteTinela Panaite
Tinela Panaite
CBCarina Balcoş
Carina Balcoş
CSCarmen Savin
Carmen Savin
NONicolae Daniel Olteanu
Nicolae Daniel Olteanu
NKNikolaos Karvelas
Nikolaos Karvelas
IZIrina Zetu
Irina Zetu
The present study aims to explore and evaluate current practices among orthodontic specialists regarding the use of mini-implants, focusing on factors influencing usage decisions, experience in placement, perceptions of outcomes, and future perspectives of these devices in orthodontic practice. It seeks to explore the association between specialists' experience levels and their perceptions of mini implants, as well as the challenges encountered in their use. It is hypothesized that orthodontic specialists' perceptions and practices regarding the usage of mini implants are influenced by various factors, including their experience, training engagement, treatment outcomes, and preferences.Material and methods: The study was conducted using an online, cross-sectional survey developed on the Survio platform to assess orthodontic specialists' perceptions of the clinical effectiveness and advantages of mini-implants in orthodontic treatments. The survey, consisting of 24 closed-ended questions in binary and multiple-choice formats, covered demographics, theoretical knowledge, clinical experience, and educational resources related to mini-implant use. Orthodontic specialists from Romania were invited to participate through the AREO association, and the survey was open for 12 weeks. Data collected from the survey were analyzed using descriptive statistics and multivariate logistic regression in SPSS software (Version 28), with a statistical significance threshold set at p < 0.05.Results: through a comprehensive analysis of survey data, the study investigates factors influencing specialists' perceptions, challenges encountered in practice, training engagement, material preferences, treatment outcomes, and indications for mini-implant usage. Notable correlations and discrepancies between documented literature and orthodontists' responses in Romania regarding mini-implant indications are explored, shedding light on the diversity of applications in orthodontic procedures highlighting the significance of education, training, and technical support in enhancing mini-implant utilization. Strategies to address barriers and promote informed decision-making among orthodontists are discussed.Conclusions: the study reveals diverse preferences and utilization patterns regarding mini-implants across different orthodontic procedures, reflecting the versatility and adaptability of these devices in addressing various clinical needs. By comparing documented literature with real-world practices, the study identifies both correlations and discrepancies, providing valuable insights into the practical application of mini-implants in orthodontic treatments.

21 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NKNikolaos Karvelas
Nikolaos Karvelas
BDBogdan Radu Dragomir
Bogdan Radu Dragomir
ACAlice Chehab
Alice Chehab
Tinela PanaiteTinela Panaite
Tinela Panaite
Moschos A PapadopoulosMoschos A Papadopoulos
Moschos A Papadopoulos
Irina nicoleta ZetuIrina nicoleta Zetu
Irina nicoleta Zetu
Background: A common strategy for the correction of Class II malocclusion is to initially distalize the maxillary molars to create a Class I relationship. Material and Methods: PubMed, Embase, Cochrane Library, Google Scholar, and Clinicaltrials.gov databases were searched to identify and retrieve orthodontic articles that evaluated non-compliance distalization appliances supported by mini-implants up to 11 November 2022. Results: A total of 505 articles were initially identified, and after applying the inclusion criteria, 28 studies were enlisted for evaluation. For the prospective studies, the Risk of bias in non-randomized studies of interventions assessment tool was used, and for the retrospective studies, the Newcastle-Ottawa quality assessment scale. Regarding the palatal devices with mini-implants, the maxillary molars were distalized with a mean value ranging from 2.4 to 5.9 mm, along with a distal tipping ranging between 0.01° and 11°, while when Pendulums were used with mini-implants, the maxillary molars were distalized with a mean value from 1.8 mm to 7.9 mm, and the distal tipping ranged from 7.34° to 22.8°. Further, in the second subgroup, including the appliances placed buccally, the maxillary molars were distalized with a mean value ranging from 1.83 mm to 4.2 mm and a distal tipping ranging between 0.6° and 4.8°. Conclusions: Non-compliance appliances supported by mini-implants are effective in maxillary molar distalization, presenting no anchorage loss of the anterior dental unit in most of the appliances, while distal tipping was found to be more pronounced when the mini-implants were used with Pendulums.

5 February 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Tinela PanaiteTinela Panaite
Tinela Panaite
CSCARMEN SAVIN
CARMEN SAVIN
NONicolae Daniel Olteanu
Nicolae Daniel Olteanu
CRCristian Romanec
Cristian Romanec
RVRaluca Maria Vieriu
Raluca Maria Vieriu
Irina nicoleta ZetuIrina nicoleta Zetu
Irina nicoleta Zetu
Objective: This study aims to investigate the mechanical behavior of titanium (Ti6Al4V) mini-implants (MIs) under varying orthodontic forces using finite element analysis (FEA) and to evaluate their performance and durability under realistic clinical conditions. Optimal orthodontic forces significantly influence the structural integrity and functional longevity of MIs while minimizing adverse effects on surrounding bone tissues. Materials and Methods: A commercially available MI (diameter: 2.0 mm, length: 12 mm) was modeled using FEA. The mandible geometry was obtained using computed tomography (CT) scanning, reconstructed in 3D using SpaceClaim software 2023.1, and discretized into 10-node tetrahedral elements in ANSYS Workbench. Material properties were assigned based on the existing literature, and the implant–bone interaction was simulated using a nonlinear frictional contact model. Orthodontic forces of 2 N and 10 N, inclined at 30°, were applied to simulate clinical loading conditions. Total displacement, von Mises stresses, equivalent strains, fatigue life, and safety factors were analyzed to assess the implant’s mechanical performance. Results: At 2 N, the MI demonstrated minimal displacement (0.0328 mm) and sustained approximately 445,000 cycles under safe fatigue loading conditions, with a safety factor of 4.8369. At 10 N, the implant’s lifespan was drastically reduced to 1546 cycles, with significantly elevated stress (6.468 × 105 MPa) and strain concentrations, indicating heightened risks of mechanical failure and bone damage. The findings revealed the critical threshold beyond which orthodontic forces compromise implant stability and peri-implant bone health. Conclusions: This study confirms that maintaining orthodontic forces within an optimal range, approximately 2 N, is essential to prolong MI lifespan and preserve bone integrity. Excessive forces, such as 10 N, lead to a rapid decline in durability and increased risks of failure, emphasizing the need for calibrated force application in clinical practice. These insights provide valuable guidance for enhancing MI performance and optimizing orthodontic treatment outcomes.