Francisco Cepeda

Dr. Francisco Cepeda


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
JMJesús Fernando Martínez-Villafañe
Jesús Fernando Martínez-Villafañe
JOJuan Carlos Ortiz-Cuellar
Juan Carlos Ortiz-Cuellar
Jesús Salvador Galindo ValdésJesús Salvador Galindo Valdés
Jesús Salvador Galindo Valdés
FCFrancisco Cepeda
Francisco Cepeda
JCJosué Gómez Casas
Josué Gómez Casas
Carlos rodrigo Muñiz ValdezCarlos rodrigo Muñiz Valdez
Carlos rodrigo Muñiz Valdez
In this research, the effect of the interelectrode distance (d) in the electrocoagulation (EC) reactor was studied. The experiments were carried out with varying d in values of 3, 5, and 9 mm during the treatment of water contaminated with fluoride (F−). The response variables analyzed were the treatment time necessary to reduce the residual concentration of F− to 1.5 mg L−1, the number of aluminum hydroxides formed, the potential drop in the reactor terminals, and the electric power consumption of the reactor. The software FLUENT version 6.3 was employed to simulate the liquid velocity profiles achieved in the reactor chamber. The results obtained show that the liquid velocity increases in the interelectrode spaces to 0.48, 0.65, and 0.86 m s−1 for interelectrode distances of 9, 5, and 3 mm, respectively, which favors not only the formation of flocs but also the elimination of fluoride. With a shorter interelectrode distance, the EC reactor not only consumes less electrical energy but also fewer electrodes, and the dispersion of generated flocs in the reactor chamber is major, which is more important than the quantity of flocs generated in it.

29 March 2025 in Metals
Verified
Journal Article
Open access
PDF file
FCFrancisco Cepeda
Francisco Cepeda
Carlos rodrigo Muñiz ValdezCarlos rodrigo Muñiz Valdez
Carlos rodrigo Muñiz Valdez
JOJuan Carlos Ortiz-Cuellar
Juan Carlos Ortiz-Cuellar
JMJesús Fernando Martínez-Villafañe
Jesús Fernando Martínez-Villafañe
Jesús Salvador Galindo ValdésJesús Salvador Galindo Valdés
Jesús Salvador Galindo Valdés
GMGladys Yerania Perez Medina
Gladys Yerania Perez Medina
The investment casting process, also known as lost-wax casting, is widely used for producing ferrous and non-ferrous metal parts due to its excellent surface finish and dimensional accuracy. In recent years, the use of Co-Cr-Mo alloy has increased due to its high corrosion resistance, good biocompatibility, and relatively high wear resistance. Laser melting of materials has been demonstrated to refine the surface grain structure, reduce surface roughness, and improve both wear and corrosion resistance. The ability to fine-tune parameters such as laser power density and scanning speed facilitates the optimization of the treated layers’ thickness and homogeneity, thereby addressing many of the shortcomings inherent in conventional methods. This study investigates the microstructural, mechanical wear and bioactive behavior of investment-cast Co-Cr-Mo parts subjected to a Nd:YAG laser surface treatment. The effects of different processing parameters were analyzed quantitatively and comprehensively. The specimens were characterized using metallographic techniques, bioactivity evaluation, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), wear testing (Pin-on-Disk), and hardness testing. Our results demonstrate that Nd:YAG laser melting significantly enhances the surface properties and maintains the dimensional accuracy of complex Co-Cr-Mo biomedical components, through microstructural refinement, increased hardness, improved wear resistance, and preserved biocompatibility. The specific combination of investment casting with precisely controlled laser surface modification represents a significant advancement for improving the longevity and performance of biomedical implants.