Jesús Fernando Martínez-Villafañe

Dr. Jesús Fernando Martínez-Villafañe

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2022 in Metals
Verified
Journal Article
Open access
PDF file
NRNelly Abigail Rodríguez Rosales
Nelly Abigail Rodríguez Rosales
Félix MontesFélix Montes
Félix Montes
OGOziel Gómez-Casas
Oziel Gómez-Casas
JCJosué Gómez Casas
Josué Gómez Casas
Jesús Salvador Galindo ValdésJesús Salvador Galindo Valdés
Jesús Salvador Galindo Valdés
Carlos rodrigo Muñiz ValdezCarlos rodrigo Muñiz Valdez
Carlos rodrigo Muñiz Valdez
This research evaluates the effect of temperature and time austempering on microstructural characteristics and hardness of ductile iron, validating the results by means of a statistical method for hardness prediction. Ductile iron was subjected to austenitization at 950 °C for 120 min and then to austempering heat treatment in a salt bath at temperatures of 290, 320, 350 and 380 °C for 30, 60, 90 and 120 min. By increasing austempering temperature, a higher content of carbon-rich austenite was obtained, and the morphology of the thin acicular ferrite needles produced at 290 °C turned completely feathery at 350 and 380 °C. A thickening of acicular ferrite needles was also observed as austempering time increased. An inversely proportional behavior of hardness values was thus obtained, which was validated through data analysis, statistical tools and a regression model taking temperature and time austempering as input variables and hardness as the output variable, which achieved a correlation among variables of about 97%. The proposal of a mathematical model for the prediction of hardness in austempered ductile iron represents a numerical approximation which validates the experimental results at 95.20%.

24 September 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
JMJesús Fernando Martínez-Villafañe
Jesús Fernando Martínez-Villafañe
JOJuan Carlos Ortiz-Cuellar
Juan Carlos Ortiz-Cuellar
Jesús Salvador Galindo ValdésJesús Salvador Galindo Valdés
Jesús Salvador Galindo Valdés
FCFrancisco Cepeda
Francisco Cepeda
JCJosué Gómez Casas
Josué Gómez Casas
Carlos rodrigo Muñiz ValdezCarlos rodrigo Muñiz Valdez
Carlos rodrigo Muñiz Valdez
In this research, the effect of the interelectrode distance (d) in the electrocoagulation (EC) reactor was studied. The experiments were carried out with varying d in values of 3, 5, and 9 mm during the treatment of water contaminated with fluoride (F−). The response variables analyzed were the treatment time necessary to reduce the residual concentration of F− to 1.5 mg L−1, the number of aluminum hydroxides formed, the potential drop in the reactor terminals, and the electric power consumption of the reactor. The software FLUENT version 6.3 was employed to simulate the liquid velocity profiles achieved in the reactor chamber. The results obtained show that the liquid velocity increases in the interelectrode spaces to 0.48, 0.65, and 0.86 m s−1 for interelectrode distances of 9, 5, and 3 mm, respectively, which favors not only the formation of flocs but also the elimination of fluoride. With a shorter interelectrode distance, the EC reactor not only consumes less electrical energy but also fewer electrodes, and the dispersion of generated flocs in the reactor chamber is major, which is more important than the quantity of flocs generated in it.

10 December 2024 in Processes
Verified
Journal Article
Open access
PDF file
JCJosué Gómez Casas
Josué Gómez Casas
Carlos Alberto Toro ArcilaCarlos Alberto Toro Arcila
Carlos Alberto Toro Arcila
NRNelly Abigail Rodríguez Rosales
Nelly Abigail Rodríguez Rosales
JFJonathan Obregon Flores
Jonathan Obregon Flores
DODaniela E. Ortíz-Ramos
Daniela E. Ortíz-Ramos
OGOziel Gómez-Casas
Oziel Gómez-Casas
This paper presents a data-driven kinematic model for the end-effector pose control applied to a variety of manipulator robots, focusing on the entire end-effector’s pose (position and orientation). The measured signals of the full pose and their computed derivatives, along with a linear combination of an estimated Jacobian matrix and a vector of joint velocities, generate a model estimation error. The Jacobian matrix is estimated using the Pseudo Jacobian Matrix (PJM) algorithm, which requires tuning only the step and weight parameters that scale the convergence of the model estimation error. The proposed control law is derived in two stages: the first one is part of an objective function minimization, and the second one is a constraint in a quasi-Lagrangian function. The control design parameters guarantee the control error convergence in a closed-loop configuration with adaptive behavior in terms of the dynamics of the estimated Jacobian matrix. The novelty of the approach lies in its ability to achieve superior tracking performance across different manipulator robots, validated through simulations. Quantitative results show that, compared to a classical inverse-kinematics approach, the proposed method achieves rapid convergence of performance indices (e.g., Root Mean Square Error (RMSE) reduced to near-zero in two cycles vs. a steady-state RMSE of 20 in the classical approach). Additionally, the proposed method minimizes joint drift, maintaining an RMSE of approximately 0.3 compared to 1.5 under the classical scheme. The control was validated by means of simulations featuring an UR5e manipulator with six Degrees of Freedom (DOF), a KUKA Youbot with eight DOF, and a KUKA Youbot Dual with thirteen DOF. The stability analysis of the closed-loop controller is demonstrated by means of the Lyapunov stability conditions.

2 June 2023 in Mathematics
Verified
Journal Article
Open access
PDF file
America MoralesAmerica Morales
America Morales
JCJosué Gómez Casas
Josué Gómez Casas
CTChidentree Treesatayapun
Chidentree Treesatayapun
Carlos rodrigo Muñiz ValdezCarlos rodrigo Muñiz Valdez
Carlos rodrigo Muñiz Valdez
Jesús Salvador Galindo ValdésJesús Salvador Galindo Valdés
Jesús Salvador Galindo Valdés
JMJesús Fernando Martínez-Villafañe
Jesús Fernando Martínez-Villafañe
Data technology advances have increased in recent years, especially for robotic systems, in order to apply data-driven modelling and control computations by only considering the input and output signals’ relationship. For a data-driven modelling and control approach, the system is considered unknown. Thus, the initialization values of the system play an important role to obtain a suitable estimation. This paper presents a methodology to initialize a data-driven model using the pseudo-Jacobian matrix algorithm to estimate the model of a mobile manipulator robot. Once the model is obtained, a control law is proposed for the robot end-effector position tasks. To this end, a novel neuro-fuzzy network is proposed as a control law, which only needs to update one parameter to minimize the control error and avoids the chattering phenomenon. In addition, a general stability analysis guarantees the convergence of the estimation and control errors and the tuning of the closed-loop control design parameters. The simulations results validate the performance of the data-driven model and control.

29 March 2025 in Metals
Verified
Journal Article
Open access
PDF file
FCFrancisco Cepeda
Francisco Cepeda
Carlos rodrigo Muñiz ValdezCarlos rodrigo Muñiz Valdez
Carlos rodrigo Muñiz Valdez
JOJuan Carlos Ortiz-Cuellar
Juan Carlos Ortiz-Cuellar
JMJesús Fernando Martínez-Villafañe
Jesús Fernando Martínez-Villafañe
Jesús Salvador Galindo ValdésJesús Salvador Galindo Valdés
Jesús Salvador Galindo Valdés
GMGladys Yerania Perez Medina
Gladys Yerania Perez Medina
The investment casting process, also known as lost-wax casting, is widely used for producing ferrous and non-ferrous metal parts due to its excellent surface finish and dimensional accuracy. In recent years, the use of Co-Cr-Mo alloy has increased due to its high corrosion resistance, good biocompatibility, and relatively high wear resistance. Laser melting of materials has been demonstrated to refine the surface grain structure, reduce surface roughness, and improve both wear and corrosion resistance. The ability to fine-tune parameters such as laser power density and scanning speed facilitates the optimization of the treated layers’ thickness and homogeneity, thereby addressing many of the shortcomings inherent in conventional methods. This study investigates the microstructural, mechanical wear and bioactive behavior of investment-cast Co-Cr-Mo parts subjected to a Nd:YAG laser surface treatment. The effects of different processing parameters were analyzed quantitatively and comprehensively. The specimens were characterized using metallographic techniques, bioactivity evaluation, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), wear testing (Pin-on-Disk), and hardness testing. Our results demonstrate that Nd:YAG laser melting significantly enhances the surface properties and maintains the dimensional accuracy of complex Co-Cr-Mo biomedical components, through microstructural refinement, increased hardness, improved wear resistance, and preserved biocompatibility. The specific combination of investment casting with precisely controlled laser surface modification represents a significant advancement for improving the longevity and performance of biomedical implants.

16 December 2025 in Coatings
Verified
Journal Article
Open access
PDF file
Carlos rodrigo Muñiz ValdezCarlos rodrigo Muñiz Valdez
Carlos rodrigo Muñiz Valdez
NRNelly Abigail Rodríguez Rosales
Nelly Abigail Rodríguez Rosales
JOJuan Carlos Ortiz-Cuellar
Juan Carlos Ortiz-Cuellar
JMJesús Fernando Martínez-Villafañe
Jesús Fernando Martínez-Villafañe
JCJosué Gómez Casas
Josué Gómez Casas
Jesús Salvador Galindo ValdésJesús Salvador Galindo Valdés
Jesús Salvador Galindo Valdés
Industrial wastewater can be reused in other everyday processes to help combat water scarcity worldwide. One contaminant in industrial wastewater is hexavalent chromium, which is highly toxic and can cause kidney, liver, and respiratory problems, making its removal vital. In this study, PLA-based films containing modified zirconia nanoparticles were developed via a solution-mixing process for hexavalent chromium adsorption. Obtaining the films involved two stages: the first was the chemical modification of ZrO2 nanoparticles with thiamine hydrochloride (vitamin B1) using fixed-frequency ultrasound at an output of 750 W and 50% amplitude for 60 min. The second stage involved preparing the films by mixing them in the solution using an ultrasonic bath. The nanoparticle concentrations were 0.25, 0.5, and 1 wt%. The results obtained from characterization using Fourier-transform infrared spectroscopy (FT-IR) revealed the characteristic bands of PLA and the characteristic peak of the Zr-O bond corresponding to the ZrO2 nanoparticles. Thermogravimetric analysis (TGA) showed that the ZrO2 nanoparticles provided thermal stability to the PLA polymer. X-ray diffraction (XRD) showed a broad peak of amorphous PLA at 16.8° and signals corresponding to the crystalline phase of ZrO2. The morphology of a cross-section of the films was observed using scanning electron microscopy (SEM), revealing a rough surface with pores. Finally, hexavalent chromium adsorption tests were carried out, measuring the adsorption efficiency under the parameters of pH, concentration, and contact time. The PLAZrO2 sample achieved an adsorption efficiency of 83% at pH 2.