Johan Guzman

Prof. Johan Guzman

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2012 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
JGJohan Guzman
Johan Guzman
Pedro E. MelinPedro E. Melin
Pedro E. Melin
Jose EspinozaJose Espinoza
Jose Espinoza
LMLuis A. Moran
Luis A. Moran
Carlos R. R BaierCarlos R. R Baier
Carlos R. R Baier
GGGonzalo A. Guinez
Gonzalo A. Guinez
Modular current source converters (MCSCs) have been proposed as an alternative method for increasing the power range of medium voltage PWM AC drives. MCSCs are built by stacking parallel current source converters. Two advantages that make MCSCs attractive are: (a) extended current/voltage ratings beyond the device ratings and (b) simplicity in balancing the DC link current in each module. This can be accomplished using two optimized modulating patterns that have been proposed for such topologies: (a) multilevel selective harmonic elimination (MSHE) and (b) displaced selective harmonic elimination (DSHE). Both techniques are based on SHE patterns but there are slight differences in their digital implementation due to the way they generate the harmonic cancellation. Furthermore, when these techniques are used in the rectifier stage, it is reported that MSHE and DSHE do not eliminate all the unwanted harmonics due to practical issues such as changes in the modulating indexes to control the DC link currents. This work compares the operation of DSHE and MSHE when used in rectifiers of an MCSC in terms of execution time, robustness to poor sampling frequency, and quality of harmonic profiles on AC input currents under different operating conditions. Experimental results are presented to validate the theoretical considerations.

11 August 2009 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JGJohan Guzman
Johan Guzman
Jose EspinozaJose Espinoza
Jose Espinoza
LMLuis A. Morán
Luis A. Morán
GJGéza Joós
Géza Joós
Modular current-source converter (MCSC) structures can enhance the current capacity and improve the power quality of converters in medium-voltage pulsewidth-modulated applications. An MCSC uses individual three-phase modules in a shunt connection to share the total power in a symmetrical manner. The modulation of these units is normally done using optimized patterns such as selective harmonic elimination patterns. However, the optimization is usually performed at the module level. This paper proposes a modulation technique that optimizes the operation of a complete MCSC taking into account all P modules. Thus, from the injected ac current, we remove P times the number of harmonics as compared with the conventional approach using the same switching frequency. A complete mathematical formulation and experimental results validate the proposed approach.

18 September 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
Roberto RamírezRoberto Ramírez
Roberto Ramírez
Jose EspinozaJose Espinoza
Jose Espinoza
Carlos R. R BaierCarlos R. R Baier
Carlos R. R Baier
Marco RiveraMarco Rivera
Marco Rivera
FVFelipe Villarroel
Felipe Villarroel
Pedro E. MelinPedro E. Melin
Pedro E. Melin
Finite control set model predictive control can be applied to a power converter if there is an accurate existing model of the converter. The best results will be achieved if and only if the parameters and variables that make up the system are properly estimated. If this is not the case, the predictions made using these strategies may be erroneous and cause problems, such as steady-state error with respect to the assigned desired references. This paper presents a predictive control strategy with integral action that compensates for the differences between the estimated model and the inverter with the objective of achieving a zero steady-state error without requiring external loops or state observers. The proposed strategy is tested on a single-phase Z-source inverter so as to evaluate the error in both the ac and dc controlled variables with respect to their references to their cosigns. The experimental results confirm that the proposed strategy achieves a zero error in the steady state while maintaining

13 February 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Carlos R. R BaierCarlos R. R Baier
Carlos R. R Baier
MTMiguel A. Torres
Miguel A. Torres
PAPablo Acuna
Pablo Acuna
JMJavier A. Munoz
Javier A. Munoz
PMPedro E. Melin
Pedro E. Melin
JGJohan Guzman
Johan Guzman
A novel control strategy for single-phase current-source inverters connected to an ac grid is proposed in this paper. The control strategy aims to inject maximum power to the grid under transient and steady-state conditions by the tracking of sinusoidal references. This paper presents the modeling and the design of the control strategy based on the exact linearization of the inverter model. Results are obtained by computational simulation and validated experimentally. By using error performance indexes in the analysis of the results, it is demonstrated that the proposed controllers achieve correct tracking of the sinusoidal reference while keeping a low switching frequency, which helps to minimize the commutation losses.

29 October 2007 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Carlos R. R BaierCarlos R. R Baier
Carlos R. R Baier
JGJohan Guzman
Johan Guzman
Jose EspinozaJose Espinoza
Jose Espinoza
MPMarcelo A. Perez
Marcelo A. Perez
Jose RodriguezJose Rodriguez
Jose Rodriguez
The analysis of a multicell topology that is implemented with single-phase nonregenerative cells under an unbalanced ac mains is presented. The study shows that the topology naturally compensates most of the voltage unbalance; for instance, for a 100% voltage unbalance in the ac mains, just 32% reaches the load. For critical applications, a feedforward control technique is proposed in order to compensate the remaining unbalance at the load side. The resulting topology, in combination with the proposed strategy, reduces near to zero the load fundamental voltage unbalance, while the input current unbalance and distortion are also improved. A theoretical analysis that is based on symmetrical components and the experimental results confirm the theoretical considerations.

1 August 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JMJavier A. Munoz
Javier A. Munoz
Jose EspinozaJose Espinoza
Jose Espinoza
Carlos R. R BaierCarlos R. R Baier
Carlos R. R Baier
LMLuis A. Moran
Luis A. Moran
JGJohan Guzman
Johan Guzman
VCVictor Cardenas
Victor Cardenas
A modular and decoupled approach to achieve harmonic cancellation in a multilevel Static Compensator (STATCOM) is presented in this paper. This work shows that it is possible to split the compensation tasks depending on the frequency components present on the line current that is intended to be compensated by using the superposition principle and the modular features of an H-bridge based multilevel STATCOM. This approach allows the implementation of the topology with dedicated modules in order to decouple and simplify the control algorithms. The H-bridge modules can be implemented with two different kinds of semiconductors: (i) slow switches for fundamental frequency compensation modules and (ii) fast switches for harmonic frequency compensation modules. As the modules meant for harmonic cancellation can self-regulate its dc voltage, they can follow the load requirements and thus operate with minimum power. The theoretical analysis is validated in a laboratory prototype.