21 June 2021 in Bio-Design and Manufacturing
Verified
Journal Article
Open access
PDF file
FHFelix Hesselmann
Felix Hesselmann
JFJannis Mathias Focke
Jannis Mathias Focke
PSPeter C. Schlanstein
Peter C. Schlanstein
NSNiklas Steuer
Niklas Steuer
AKAndreas Kaesler
Andreas Kaesler
Jutta ArensJutta Arens
Jutta Arens
Currently, artificial-membrane lungs consist of thousands of hollow fiber membranes where blood flows around the fibers and gas flows inside the fibers, achieving diffusive gas exchange. At both ends of the fibers, the interspaces between the hollow fiber membranes and the plastic housing are filled with glue to separate the gas from the blood phase. During a uniaxial centrifugation process, the glue forms the “potting.” The shape of the cured potting is then determined by the centrifugation process, limiting design possibilities and leading to unfavorable stagnation zones associated with blood clotting. In this study, a new multiaxial centrifugation process was developed, expanding the possible shapes of the potting and allowing for completely new module designs with potentially superior blood flow guidance within the potting margins. Two-phase simulations of the process in conceptual artificial lungs were performed to explore the possibilities of a biaxial centrifugation process and determine suitable parameter sets. A corresponding biaxial centrifugation setup was built to prove feasibility and experimentally validate four conceptual designs, resulting in good agreement with the simulations. In summary, this study shows the feasibility of a multiaxial centrifugation process allowing greater variety in potting shapes, eliminating inefficient stagnation zones and more favorable blood flow conditions in artificial lungs. Graphic abstract

31 March 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
LSLasse Johannes Strudthoff
Lasse Johannes Strudthoff
JFJannis Mathias Focke
Jannis Mathias Focke
FHFelix Hesselmann
Felix Hesselmann
AKAndreas Kaesler
Andreas Kaesler
ACAna Martins Costa
Ana Martins Costa
SJSebastian Victor Jansen
Sebastian Victor Jansen
The overall survival rate of extracorporeal life support (ECLS) remains at 60%. Research and development has been slow, in part due to the lack of sophisticated experimental models. This publication introduces a dedicated rodent oxygenator (“RatOx”) and presents preliminary in vitro classification tests. The RatOx has an adaptable fiber module size for various rodent models. Gas transfer performances over the fiber module for different blood flows and fiber module sizes were tested according to DIN EN ISO 7199. At the maximum possible amount of effective fiber surface area and a blood flow of 100 mL/min, the oxygenator performance was tested to a maximum of 6.27 mL O2/min and 8.2 mL CO2/min, respectively. The priming volume for the largest fiber module is 5.4 mL, while the smallest possible configuration with a single fiber mat layer has a priming volume of 1.1 mL. The novel RatOx ECLS system has been evaluated in vitro and has demonstrated a high degree of compliance with all pre-defined functional criteria for rodent-sized animal models. We intend for the RatOx to become a standard testing platform for scientific studies on ECLS therapy and technology.

31 December 2021 in Membranes
Verified
Journal Article
Open access
PDF file
NSNiklas Steuer
Niklas Steuer
PSPeter C. Schlanstein
Peter C. Schlanstein
AHAnke Hannig
Anke Hannig
SSStephan Sibirtsev
Stephan Sibirtsev
AJAndreas Jupke
Andreas Jupke
Jutta ArensJutta Arens
Jutta Arens
Carbon monoxide (CO) poisoning is the leading cause of poisoning-related deaths globally. The currently available therapy options are normobaric oxygen (NBO) and hyperbaric oxygen (HBO). While NBO lacks in efficacy, HBO is not available in all areas and countries. We present a novel method, extracorporeal hyperoxygenation therapy (EHT), for the treatment of CO poisoning that eliminates the CO by treating blood extracorporeally at elevated oxygen partial pressure. In this study, we proof the principle of the method in vitro using procine blood: Firstly, we investigated the difference in the CO elimination of a hollow fibre membrane oxygenator and a specifically designed batch oxygenator based on the bubble oxygenator principle at elevated pressures (1, 3 bar). Secondly, the batch oxygenator was redesigned and tested for a broader range of pressures (1, 3, 5, 7 bar) and temperatures (23, 30, 37 °C). So far, the shortest measured carboxyhemoglobin half-life in the blood was 21.32 min. In conclusion, EHT has the potential to provide an easily available and effective method for the treatment of CO poisoning.

22 January 2022 in Membranes
Verified
Journal Article
Open access
PDF file
LSLasse Johannes Strudthoff
Lasse Johannes Strudthoff
HLHannah Lüken
Hannah Lüken
SJSebastian Victor Jansen
Sebastian Victor Jansen
JPJan Petran
Jan Petran
PSPeter C. Schlanstein
Peter C. Schlanstein
RKRüdger Kopp
Rüdger Kopp
Extracorporeal membrane oxygenation (ECMO) is an established rescue therapy for patients with chronic respiratory failure waiting for lung transplantation (LTx). The therapy inherent immobilization may result in fatigue, consecutive deteriorated prognosis, and even lost eligibility for transplantation. We conducted a feasibility study on a novel system designed for the deployment of a portable ECMO device, enabling the physical exercise of awake patients prior to LTx. The system comprises a novel oxygenator with a directly connected blood pump, a double-lumen cannula, gas blender and supply, as well as control and energy management. In vitro experiments included tests regarding performance, efficiency, and blood damage. A reduced system was tested in vivo for feasibility using a novel large animal model. Six anesthetized pigs were first positioned in supine position, followed by a 45° angle, simulating an upright position of the patients. We monitored performance and vital parameters. All in vitro experiments showed good performance for the respective subsystems and the integrated system. The acute in vivo trials of 8 h duration confirmed the results. The novel portable ECMO-system enables adequate oxygenation and decarboxylation sufficient for, e.g., the physical exercise of designated LTx-recipients. These results are promising and suggest further preclinical studies on safety and efficacy to facilitate translation into clinical application.

2 May 2020 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
JPJan Petran
Jan Petran
TMThorsten Muelly
Thorsten Muelly
RDRolf Dembinski
Rolf Dembinski
NSNiklas Steuer
Niklas Steuer
Jutta ArensJutta Arens
Jutta Arens
RKRüdger Kopp
Rüdger Kopp
Background: RESP score and PRESERVE score have been validated for veno-venous Extracorporeal Membrane Oxygenation in severe ARDS to assume individual mortality risk. ARDS patients with low-flow Extracorporeal Carbon Dioxide Removal, especially pumpless Extracorporeal Lung Assist, have also a high mortality rate, but there are no validated specific or general outcome scores. This retrospective study tested whether these established specific risk scores can be validated for pumpless Extracorporeal Lung Assist in ARDS patients in comparison to a general organ dysfunction score, the SOFA score. Methods: In a retrospective single center cohort study we calculated and evaluated RESP, PRESERVE, and SOFA score for 73 ARDS patients with pumpless Extracorporeal Lung Assist treated between 2002 and 2016 using the XENIOS iLA Membrane Ventilator. Six patients had a mild, 40 a moderate and 27 a severe ARDS according to the Berlin criteria. Demographic data and hospital mortality as well as ventilator settings, hemodynamic parameters, and blood gas measurement before and during extracorporeal therapy were recorded. Results: Pumpless Extracorporeal Lung Assist of mechanical ventilated ARDS patients resulted in an optimized lung protective ventilation, significant reduction of PaCO2, and compensation of acidosis. Scoring showed a mean score of alive versus deceased patients of 3 ± 1 versus − 1 ± 1 for RESP (p < 0.01), 3 ± 0 versus 6 ± 0 for PRESERVE (p < 0.05) and 8 ± 1 versus 10 ± 1 for SOFA (p < 0.05). Using receiver operating characteristic curves, area under the curve (AUC) was 0.78 (95% confidence interval (CI) 0.67–0.89, p < 0.01) for RESP score, 0.80 (95% CI 0.70–0.90, p < 0.0001) for PRESERVE score and 0.66 (95% CI 0.53–0.79, p < 0.05) for SOFA score. Conclusions: RESP and PRESERVE scores were superior to SOFA, as non-specific critical care score. Although scores were developed for veno-venous ECMO, we could validate RESP and PRESERVE score for pumpless Extracorporeal Lung Assist. In conclusion, RESP and PRESERVE score are suitable to estimate mortality risk of ARDS patients with an arterio-venous pumpless Extracorporeal Carbon Dioxide Removal.

13 May 2020 in Cardiovascular Engineering and Technology
Verified
Journal Article
Open access
PDF file
NSNiklas Steuer
Niklas Steuer
KHK. Hugenroth
K. Hugenroth
TBT. Beck
T. Beck
JSJ. Spillner
J. Spillner
RKR. Kopp
R. Kopp
Jutta ArensJutta Arens
Jutta Arens
Purpose: Currently used cannulae for extracorporeal carbon dioxide removal (ECCO2R) are associated with complications such as thrombosis and distal limb ischemia, especially for long-term use. We hypothesize that the risk of these complications is reducible by attaching hemodynamically optimized grafts to the patient’s vessels. In this study, as a first step towards a long-term stable ECCO2R connection, we investigated the feasibility of a venovenous connection to the common iliac veins. To ensure its applicability, the drainage of reinfused blood (recirculation) and high wall shear stress (WSS) must be avoided. Methods: A reference model was selected for computational fluid dynamics, on the basis of the analysis of imaging data. Initially, a sensitivity analysis regarding recirculation was conducted using as variables: blood flow, the distance of drainage and return to the iliocaval junction, as well as the diameter and position of the grafts. Subsequently, the connection was optimized regarding recirculation and the WSS was evaluated. We validated the simulations in a silicone model traversed by dyed fluid. Results: The simulations were in good agreement with the validation measurements (mean deviation 1.64%). The recirculation ranged from 32.1 to 0%. The maximum WSS did not exceed 5.57 Pa. The position and diameter of the return graft show the highest influence on recirculation. A correlation was ascertained between recirculation and WSS. Overall, an inflow jet directed at a vessel wall entails not only high WSS, but also a flow separation and thereby an increased recirculation. Therefore, return grafts aligned to the vena cava are crucial. Conclusion: In conclusion, a connection without recirculation could be feasible and therefore provides a promising option for a long-term ECCO2R connection.