C. L. Faria

Dr. C. L. Faria

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CFC. L. Faria
C. L. Faria
Marcos MartinsMarcos Martins
Marcos Martins
TMT. Matos
T. Matos
Rui A. LimaRui A. Lima
Rui A. Lima
João M. MirandaJoão M. Miranda
João M. Miranda
Luís Miguel GoncalvesLuís Miguel Goncalves
Luís Miguel Goncalves
A linear electromagnetic energy harvesting device for underwater applications, fabricated with a simple manufacturing process, was developed to operate with movement frequencies from 0.1 to 0.4 Hz. The generator has two coils, and the effect of the combination of the two coils was investigated. The experimental study has shown that the energy capture system was able to supply energy to several ocean sensors, producing 7.77 mJ per second with wave movements at 0.4 Hz. This study shows that this energy is enough to restore the energy used by the battery or the capacitor and continue supplying energy to the sensors used in the experimental work. For an ocean wave frequency of 0.4 Hz, the generator can supply power to 8 sensors or 48 sensors, depending on the energy consumed and its optimization.

13 August 2025 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Beatriz D. CardosoBeatriz D. Cardoso
Beatriz D. Cardoso
ASAndrews Souza
Andrews Souza
GNGlauco Nobrega
Glauco Nobrega
IAInês Santos Afonso
Inês Santos Afonso
LNLucas Boniatti Neves
Lucas Boniatti Neves
Rui A. LimaRui A. Lima
Rui A. Lima
Nanofluids (NFs), consisting of nanoparticles (NPs) suspended in base fluids, have attracted growing interest due to their superior physicochemical properties and multifunctional potential. In this review, conventional and green NF technology aspects, including synthesis routes, formulation, and applications, are discussed. Conventional NFs, involving NPs synthesized using physical and chemical approaches, have improved NP morphology control but are likely to cause environmental and safety concerns. In contrast, green NFs that are plant extract, microorganism, and biogenic waste-based represent a sustainable and biocompatible alternative. The effect of key parameters (e.g., NP size, shape, concentration, dispersion stability, and base fluid properties) on the performance of NFs is critically examined. The review also covers potential applications: in biomedical engineering (e.g., drug delivery, imaging, theranostics, and antimicrobial therapies), in heat transfer (e.g., solar collectors, cooling electronics, nuclear reactors), and precision machining (e.g., lubricants and coolants). Comparative insights regarding green versus conventionally prepared NFs are provided concerning their toxicity, environmental impact, scalability, and functional performance across various applications. Overall, this review highlights the new promise of both green and conventional NFs and provides key opportunities and challenges to guide future developments in this field.

4 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TMT. Matos
T. Matos
CFC. L. Faria
C. L. Faria
Marcos MartinsMarcos Martins
Marcos Martins
RHRenato Henriques
Renato Henriques
PGPedro Teixeira Gomes
Pedro Teixeira Gomes
Luís Miguel GoncalvesLuís Miguel Goncalves
Luís Miguel Goncalves
A cost-effective optical instrument for continuous in-situ monitoring applications is presented. With a production cost in raw materials of 38 €, a power consumption of 300 A in sleep mode and 100 mA in active mode (5 ms reading), and a capacity to monitor turbidity and sedimentary displacement at eight different depths in the water column, the sensor was developed for sediment monitoring in coastal areas. Due to the extent and dynamics of the processes involved in these areas, observations require a wide spatial and temporal resolution. Each of the eight monitoring nodes uses one infrared backscatter channel, to estimate turbidity and sediment concentration, and one ultraviolet with one infrared transmitted light channels to distinguish organic/inorganic composition of the suspended material load. An in-lab calibration was conducted, using formazine to correlate turbidity with the electronic outputs of the instrument. An analysis of the influence of external light sources and correction techniques were performed. Moreover, an in-lab experiment was conducted to study the behaviour of the sensor-to-sediment transport, wash load and sediment accumulation. The device was deployed, with a water level sensor, in an estuarine area with high sediment dynamics. The monitoring data were analysed, showing the potential of the device to continuously monitor turbidity, sediment processes, and distinguish between organic and inorganic matter, at the different depths in the water column.

14 January 2026 in Progress in Materials Science
Verified
Journal Article
Open access
Beatriz D. CardosoBeatriz D. Cardoso
Beatriz D. Cardoso
GNGlauco Nobrega
Glauco Nobrega
IAInês Santos Afonso
Inês Santos Afonso
ASAndrews Souza
Andrews Souza
LNLucas Boniatti Neves
Lucas Boniatti Neves
Rui A. LimaRui A. Lima
Rui A. Lima

1 February 2024 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
MSMariana P. Salgueiro
Mariana P. Salgueiro
FPFabio Andre Magalhães Pereira
Fabio Andre Magalhães Pereira
CFC. L. Faria
C. L. Faria
EPEduardo Nuno Borges Pereira
Eduardo Nuno Borges Pereira
JAJoão A.P.P. Almeida
João A.P.P. Almeida
NDNuno Dourado
Nuno Dourado
In additive manufacturing (AM), one of the most popular procedures is material extrusion (MEX). The materials and manufacturing parameters used in this process have a significant impact on a printed product’s quality. The purpose of this work is to investigate the effects of infill percentage and filament orientation on the mechanical properties of printed structures. For this reason, the characterisation of polylactic acid (PLA) was done numerically using the finite element method and experimentally through mechanical tests. The experiments involved three-point bending and tensile tests. The results showed that mechanical performance is highly dependent on these processing parameters mainly when the infill percentage is less than 100%. The highest elastic modulus was exhibited for structures with filament align at 0° and 100% infill, while the lowest one was verified for specimen filament aligned at 0° and 30% infill. The results demonstrated that the process parameters have a significant impact on mechanical performance, particularly when the infill percentage is less than 100%. Structures with filament aligned at 0° and 100% infill showed the maximum elastic modulus, whereas specimens with filament oriented at 0° and 30% infill showed the lowest. The obtained numerical agreement indicated that an inverse method based only on the load–displacement curve can yield an accurate value for this material’s elastic modulus.