Minja Miličić Lazić

Dr. Minja Miličić Lazić

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2022 in Molecules
Verified
Journal Article
Open access
PDF file
Minja Miličić LazićMinja Miličić Lazić
Minja Miličić Lazić
PMPeter Majeric
Peter Majeric
VLVojkan Lazić
Vojkan Lazić
Jelena MilasinJelena Milasin
Jelena Milasin
Milica Jaksic KarisikMilica Jaksic Karisik
Milica Jaksic Karisik
KRKatarina Radović
Katarina Radović
Nickel–titanium alloys used in dentistry have a variety of mechanical, chemical, and biofunctional properties that are dependent on the manufacturing process. The aim of this study was to compare the mechanical and biofunctional performances of a nickel–titanium alloy produced by the continuous casting method (NiTi-2) with commercial nitinol (NiTi-1) manufactured by the classical process, i.e., from remelting in a vacuum furnace with electro-resistive heating and final casting into ingots. The chemical composition of the tested samples was analyzed using an energy dispersive X-ray analysis (EDX) and X-ray fluorescence (XRF). Electron backscatter diffraction (EBSD) quantitative microstructural analysis was performed to determine phase distribution in the samples. As part of the mechanical properties, the hardness on the surface of samples was measured with the static Vickers method. The release of metal ions (Ni, Ti) in artificial saliva (pH 6.5) and lactic acid (pH 2.3) was measured using a static immersion test. Finally, the resulting corrosion layer was revealed by means of a scanning electron microscope (SEM), which allows the detection and direct measurement of the formatted oxide layer thickness. To assess the biocompatibility of the tested nickel–titanium alloy samples, an MTT test of fibroblast cellular proliferation on direct contact with the samples was performed. The obtained data were analyzed with the IBM SPSS Statistics v22 software. EDX and XRF analyses showed a higher presence of Ni in the NiTi-2 sample. The EBSD analysis detected an additional NiTi2-cubic phase in the NiTi-2 microstructure. Additionally, in the NiTi-2 higher hardness was measured. An immersion test performed in artificial saliva after 7 days did not induce significant ion release in either group of samples (NiTi-1 and NiTi-2). The acidic environment significantly increased the release of toxic ions in both types of samples. However, Ni ion release was two times lower, and Ti ion release was three times lower from NiTi-2 than from NiTi-1. Comparison of the cells’ mitochondrial activity between the NiTi-1 and NiTi-2 groups did not show a statistically significant difference. In conclusion, we obtained an alloy of small diameter with an appropriate microstructure and better response compared to classic NiTi material. Thus, it appears from the present study that the continuous cast technology offers new possibilities for the production of NiTi material for usage in dentistry.

11 January 2024 in Metals
Verified
Journal Article
Open access
PDF file
Minja Miličić LazićMinja Miličić Lazić
Minja Miličić Lazić
DTDijana Mitic (former Trisic)
Dijana Mitic (former Trisic)
KRKatarina Radović
Katarina Radović
IDIgor Djordjevic
Igor Djordjevic
PMPeter Majeric
Peter Majeric
Branimir GrgurBranimir Grgur
Branimir Grgur
Variations in the corrosion behavior of biomedical NiTi alloys in Cl− containing and acidic environments present a problem with their biological implantation. The objective of this research was to evaluate the synergy of the microstructure, the corrosion behavior, and the biocompatibility of novel continuous-cast NiTi alloys and to compare them with commercial NiTi alloys. The two alloys have a practically identical nominal chemical composition, but they differ in production technology. The continuous casting technology involved vacuum induction melting of the basic components and vertical continuous casting, while the commercial NiTi alloy was produced through a process of casting, hot rolling, and forming into square shapes. The microstructure was revealed to determine the surface area and size of grains. The corrosion of a commercial nickel–titanium alloy and one prepared by a novel continuous casting method in acidic and chloride-containing solutions was studied via analytical and electrochemical tests. Localized corrosion characteristics related to oxide properties, when exposed to 9 g L−1 NaCl solution, were examined with focused ion beam analysis and subsequent microchemical analysis of the formed corrosive products. Corrosion potential over time and the oxide film resistance were analyzed using linear polarization measurements. To obtain a preliminary estimate of biocompatibility, human fibroblast cells were used in indirect contact, i.e., alloy conditioning medium. The continuous casting method resulted in a reduction in the average grain size in comparison to the commercial sample and better corrosion stability of the sample in an acidic environment. Also, in a solution of 9 g L−1 NaCl the commercial sample showed high values for the corrosion current density (jcorr = 6 μA cm−2), which indicated low corrosion resistance, while the continuous casting sample possessed much better corrosion stability and lower values for the corrosion current density (jcorr = 0.2 μA cm−2). In line with that, elemental analysis of the corroded surfaces showed higher Cl− ion deposition over the surface layer of the commercial sample, suggesting local oxide breakdown. Moreover, NiTicc reached a value three times higher for polarization resistance (Rp = 270 kΩ cm2) over time in comparison to the commercial sample (Rp~100 kΩ cm2). Biocompatibility evaluation showed that human fibroblast cells exhibited altered metabolic activity. An MTT assay showed that cells’ mitochondrial activity dropped below that of control cells in the presence of both materials’ supernatants.

14 July 2025 in Coatings
Verified
Journal Article
Open access
PDF file
Božana PetrovićBožana Petrović
Božana Petrović
DTDijana Mitic (former Trisic)
Dijana Mitic (former Trisic)
Minja Miličić LazićMinja Miličić Lazić
Minja Miličić Lazić
Milos Milan LazarevicMilos Milan Lazarevic
Milos Milan Lazarevic
Anka Trajkovska PetkoskaAnka Trajkovska Petkoska
Anka Trajkovska Petkoska
Vukoman JokanovicVukoman Jokanovic
Vukoman Jokanovic
Stainless steel (SS) is one of the materials most commonly utilized for fabrication of medical implants and its properties are often improved by deposition of protective coatings. This study investigates certain physico-chemical and biological properties of SS substrate coated with multilayer thin film consisting of titanium nitride and silver layers (TiN-Ag film). TiN-Ag films were deposited on the surface of AISI 316 SS substrate by a combination of cathodic arc evaporation and DC magnetron sputtering. SS substrate was analyzed by TEM, while deposited coatings were analyzed by SEM, EDS and wettability measurements. Also, mitochondrial activity assay, and osteogenic and chondrogenic differentiation were performed on dental pulp stem cells (DPSCs). SEM and EDS revealed excellent adhesion between coatings’ layers, with the top layer predominantly composed of Ag, which is responsible for antibacterial properties. TiN-Ag film exhibited moderately hydrophilic behaviour which is desirable for orthopedic implant applications. Biological assays revealed significantly higher mitochondrial activity and enhanced osteogenic and chondrogenic differentiation of DPSC on TiN-Ag films compared to TiN films. The newly designed TiN-Ag coatings showed a great potential for the surface modification of SS implants, and further detailed investigations will explore their suitability for application in clinical practice.

29 July 2022 in Processes
Verified
Journal Article
Open access
PDF file
MLMarko Vojkan Lazić
Marko Vojkan Lazić
Minja Miličić LazićMinja Miličić Lazić
Minja Miličić Lazić
Milica Jaksic KarisikMilica Jaksic Karisik
Milica Jaksic Karisik
Milos Milan LazarevicMilos Milan Lazarevic
Milos Milan Lazarevic
AJAndraž Jug
Andraž Jug
Jelena MilasinJelena Milasin
Jelena Milasin
Cu-Al-Nishape memory alloys (SMAs) are widely known for their better properties in comparison to other SMAs (lower production costs, increased ductility, enhanced machinability, reduced liquidus temperature, and decreased hysteresis), but there is still controversy in terms of the biological properties of these materials. The aim of this study was to evaluate biofunctional performances of Cu-Al-Ni alloy produced by continuous casting. The micro-chemical analysis was investigated by SEM/EDX. Immersion tests performed for seven days were used to estimate the quantity of Cu, Al, and Ni ions released in neutral pH and slightly acidic artificial saliva. To assess the biocompatibility of the Cu-Al-Ni alloy samples, MTT assay on fibroblasts and dental pulp cells was performed in indirect and direct contact with samples after 1,3, and 7 days.The study revealed that continuous casting enables the primary fabrication of Cu-Al-Ni rods with a shape memory effect. Samples immersed in artificial saliva with 6.5 pH value showed no significant amounts of released ions, despite the high concentration of copper in the alloy. However, in the acidic environment, the suppression of Cu was 0.14 µg/cm2, Al 1.9 µg/cm2, and Ni 0.73 µg/cm2, and as expected, it was confirmed that Cu-Al-Ni alloy is not corrosion resistant in an acidic environment. In conclusion, this study showed that biocompatibility concerns are related only to materials with a high Cu content in acidic environments. Oppositely, small doses of Cu ions promote cell proliferation, which might be useful in further attempts to enrich different biomedical materials with copper.

21 March 2024
Verified
Book Chapter
Open access
PDF file
Minja Miličić LazićMinja Miličić Lazić
Minja Miličić Lazić
MBMarijana Popović Bajić
Marijana Popović Bajić
IDIgor Djordjevic
Igor Djordjevic
MŽMarija Slavoljub Živković
Marija Slavoljub Živković
VLVojkan Lazić
Vojkan Lazić
SŽSlavoljub Živković
Slavoljub Živković
Nickel-titanium alloys are the most common shape memory alloys (SMA) widely used in dentistry. The attractive properties of Ni-Ti BioSMAs (shape memory effect, superelasticity, good corrosion, wear resistance, and good biocompatibility) make them highly desirable candidates for the design of implants, prosthetic components, orthodontic wires, and endodontic files. The aim of this chapter is to present the advantages of Ni-Ti alloy in dentistry through a selection of optimal chemical composition and various surface treatments (mechanical polishing, electrochemical polishing, chemical etching in acid solutions, heat treatment). The osteoconductivity of the Ni-Ti alloy on human bone cells and the anticorrosive and antibacterial effects of nanocoating orthodontic wires were tested. The results on human bone cells suggested good adhesion and proliferation of osteoblast-like cells to nickel-titanium surfaces, which could improve osseointegration of the potential dental implants. A study of magnetron sputtering method (MS) with TiN-Cu-nanocoatings on orthodontic archwires showed favorable results in corrosion resistance and antibacterial properties. Future improvement of mechanical properties is focused on applying various methods of surface modifications, especially applying coatings with antibacterial properties.

21 July 2025 in Metals
Verified
Journal Article
Open access
PDF file
Aleksandra S PopovićAleksandra S Popović
Aleksandra S Popović
Minja Miličić LazićMinja Miličić Lazić
Minja Miličić Lazić
DTDijana Mitic (former Trisic)
Dijana Mitic (former Trisic)
LRLazar Rakočević
Lazar Rakočević
DJDragana Jugović
Dragana Jugović
Branimir GrgurBranimir Grgur
Branimir Grgur
The anodic oxidation of titanium implants is a practical, cost-effective method to enhance implant success, especially due to rising hypersensitivity concerns. This study investigated the electrochemical behavior, surface characteristics, and biocompatibility of anodized commercially pure titanium (cpTi, grade IV). Anodization is performed on polished, cleaned cpTi sheet samples in 1 M H2SO4 using a constant voltage of 15 V for 15 and 45 min. The color of the oxide layer is evaluated using the CIELab color space, while composition is analyzed by a scanning electron microscope (SEM) equipped with an energy dispersive spectrometer (EDS). Additionally, X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) are performed to identify and monitor the phase transformations of the formed titanium oxides. Corrosion measurements are performed in 9 g L−1 NaCl, pH = 7.4, and show the excellent corrosion stability of the anodized samples in comparison with pure titanium. The biological response is assessed by determining mitochondrial activity and gene expression in human fibroblasts. Anodized surfaces, particularly Ti-45, promote higher mitochondrial activity and the upregulation of adhesion-related genes (N-cadherin and Vimentin) in human gingival fibroblasts, indicating improved biocompatibility and the potential for enhanced early soft tissue integration.