In this research work, we synthesised poly(methyl methacrylate) (PMMA) enriched with 2 wt.% zinc oxide nanoparticles (ZnO) through conventional heat polymerisation and characterised its microstructure. It was found that the distribution of ZnO nanoparticles was homogeneous through the volume of the PMMA. The mechanical testing of the PMMA-ZnO composite primarily included the determination of the compressive properties on real dentures, while density measurements were performed using a pycnometer. The testing of functional properties involved the identification of the colour of the new PMMA-ZnO composite, where pure PMMA acted as a control. In the second step, the PMMA-ZnO cytotoxicity assays were measured in vitro, which were shown to be similar to the control PMMA. Based on this, it could be concluded that the newly formed PMMA-ZnO composite did not induce direct or indirect cytotoxic effects in L929 cell cultures; therefore, according to ISO/DIN 10993-5:2009, this composite was categorised as non-cytotoxic.
Dentures and epitheses are mostly made from poly(methyl methacrylate) (PMMA), which does not show antimicrobial properties. They present reservoirs of microorganisms grown in biofilms. The aim of this study is to prepare a PMMA enriched with gold nanoparticles (AuNPs)-PMMA/AuNPs and the examination of its physical, mechanical and antimicrobial properties. The AuNPS were synthetized from HAuCl4 using the ultrasonic spray pyrolysis method with lyophilization. The PMMA/AuNP samples were compared to PMMA samples. Density was measured by pycnometer. Microhardness was evaluated using the Vickers hardness test. Monomicrobial biofilm formation (Streptococcus mitis, Candida albicans, Staphylococcus aureus and Escherichia coli) was measured by colony-forming units (CFUs) and MTT test and visualized by SEM. AuNP release was measured indirectly (the CFUs of the medium around the sample). The density and microhardness of the PMMA/AuNPs were similar to those of the PMMA. CFU and MTT values for the biofilms formed on the PMMA for each of the tested species were higher than those of the biofilms formed on the PMMA/AuNPs. The CFUs of the medium around the sample were similar for both materials. PMMA/AuNPs showed a significant reduction in the monomicrobial biofilms of all tested species. AuNPs are not released from PMMA/AuNPs. Density, indirect measurement of residual monomer and dentures weight were similar between PMMA and PMMA/AuNPs. Microhardness, as a measure of the wear resistance, was also similar between tested discs.
Nickel–titanium alloys used in dentistry have a variety of mechanical, chemical, and biofunctional properties that are dependent on the manufacturing process. The aim of this study was to compare the mechanical and biofunctional performances of a nickel–titanium alloy produced by the continuous casting method (NiTi-2) with commercial nitinol (NiTi-1) manufactured by the classical process, i.e., from remelting in a vacuum furnace with electro-resistive heating and final casting into ingots. The chemical composition of the tested samples was analyzed using an energy dispersive X-ray analysis (EDX) and X-ray fluorescence (XRF). Electron backscatter diffraction (EBSD) quantitative microstructural analysis was performed to determine phase distribution in the samples. As part of the mechanical properties, the hardness on the surface of samples was measured with the static Vickers method. The release of metal ions (Ni, Ti) in artificial saliva (pH 6.5) and lactic acid (pH 2.3) was measured using a static immersion test. Finally, the resulting corrosion layer was revealed by means of a scanning electron microscope (SEM), which allows the detection and direct measurement of the formatted oxide layer thickness. To assess the biocompatibility of the tested nickel–titanium alloy samples, an MTT test of fibroblast cellular proliferation on direct contact with the samples was performed. The obtained data were analyzed with the IBM SPSS Statistics v22 software. EDX and XRF analyses showed a higher presence of Ni in the NiTi-2 sample. The EBSD analysis detected an additional NiTi2-cubic phase in the NiTi-2 microstructure. Additionally, in the NiTi-2 higher hardness was measured. An immersion test performed in artificial saliva after 7 days did not induce significant ion release in either group of samples (NiTi-1 and NiTi-2). The acidic environment significantly increased the release of toxic ions in both types of samples. However, Ni ion release was two times lower, and Ti ion release was three times lower from NiTi-2 than from NiTi-1. Comparison of the cells’ mitochondrial activity between the NiTi-1 and NiTi-2 groups did not show a statistically significant difference. In conclusion, we obtained an alloy of small diameter with an appropriate microstructure and better response compared to classic NiTi material. Thus, it appears from the present study that the continuous cast technology offers new possibilities for the production of NiTi material for usage in dentistry.
Cobalt-chromium (CoCr) alloys have been used in dentistry for dental bridges, crowns and implants for decades. When using CoCr alloys, a number of fractures have occurred in the Dental Laboratory, both when handling the castings and after they have been placed in the patient’s mouth. It is assumed that the key cause of the resulting fractures of CoCr dental bridges is the casting process, which includes the preparation and mixing of the basic components of the CoCr dental alloy, unstable solidification and the final treatment of the tooth casting surface. The aim of this study was, therefore, to examine three castings differently prepared from the CoCr alloy. For the initial CoCr alloy, we selected the one supplied directly from the manufacturer; three test samples were CoCr alloy remelted four times in the same crucible, while the fourth sample was the remaining solidified alloy from the crucible, taken at the last remelting. Characterisation of the microstructure of all four samples was performed by optical and scanning electron microscopy equipped with an energy dispersive X-ray spectroscope and X-ray diffractometry. Microhardness measurements were also performed. The investigation revealed that the microstructure of the castings is composed of a CoCr alloy matrix with a eutectic interdendritic composition and interdendritic precipitates, which were rich in W and Mo. The two oxides were identified as chromium oxide with silicon content and chromium oxide, which originated from the CoCr alloy as casting residue. The high content of silicon in the chromium oxide can be attributed to the silicon oxide from the ceramic melting crucible, mixed in with the remains from the CoCr alloy melting. The second oxide showed a more regular elemental content for chromium oxide, mixed with a small quantity of impurities and the casting CoCr alloy. Based on this research, some recommendations were made for working with CoCr alloys in the Dental Laboratory, with the aim of reducing the risk of dental bridge fractures in the future.
In modern times, more and more different materials (including alloys) are in direct contact with human electrolytes (sweat, saliva, lymph, blood, etc.). One of the most important properties for the use of these materials is therefore their chemical inertness or resistance to corrosion when they are in contact with human electrolytes. Consequently, during the development of such new materials, it is necessary to study and understand their basic electrochemical behaviour in a given environment. The purpose of this research was to monitor the electrochemical behaviour of the new Au-Ge alloy in artificial sweat and artificial saliva solutions, depending on the electrolyte composition and exposure time. This new alloy represents a potential material for use in dentistry or for jewellery. The obtained results of the study show that the immersion time and the pH value have a significantly greater influence on the corrosion resistance of the new Au-Ge alloy than the composition of the electrolyte solution. The results of the SEM/EDX analysis additionally confirm the main results of the electrochemical measurements.
Nickel-titanium alloys are the most common shape memory alloys (SMA) widely used in dentistry. The attractive properties of Ni-Ti BioSMAs (shape memory effect, superelasticity, good corrosion, wear resistance, and good biocompatibility) make them highly desirable candidates for the design of implants, prosthetic components, orthodontic wires, and endodontic files. The aim of this chapter is to present the advantages of Ni-Ti alloy in dentistry through a selection of optimal chemical composition and various surface treatments (mechanical polishing, electrochemical polishing, chemical etching in acid solutions, heat treatment). The osteoconductivity of the Ni-Ti alloy on human bone cells and the anticorrosive and antibacterial effects of nanocoating orthodontic wires were tested. The results on human bone cells suggested good adhesion and proliferation of osteoblast-like cells to nickel-titanium surfaces, which could improve osseointegration of the potential dental implants. A study of magnetron sputtering method (MS) with TiN-Cu-nanocoatings on orthodontic archwires showed favorable results in corrosion resistance and antibacterial properties. Future improvement of mechanical properties is focused on applying various methods of surface modifications, especially applying coatings with antibacterial properties.