caihui zhu

Dr. caihui zhu

Fudan University, Shanghai, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
HWhao wang
hao wang
XYXingjian Yang
Xingjian Yang
NMNaerzhuoli Madeniyeti
Naerzhuoli Madeniyeti
Jian QiuJian Qiu
Jian Qiu
CZcaihui zhu
caihui zhu
Kefu LiuKefu Liu
Kefu Liu
In clinical surgery, high frequency electric welding is routinely utilized to seal and fuse soft tissues. This procedure denatures collagen by electrothermal coupling, resulting in the formation of new molecular crosslinks. It is critical to understand the temperature distribution and collagen structure changes during welding in order to prevent thermal damage caused by heat generated during welding. In this study, a method combining optical measurement and simulation was presented to evaluate the temperature distribution of vascular tissue during welding, with a fitting degree larger than 97% between simulation findings and measured data. Integrating temperature distribution data, strength test data, and Raman spectrum data, it is discovered that optimal parameters exist in the welding process that may effectively prevent thermal damage while assuring welding strength.

28 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LYLi Yin
Li Yin
CZcaihui zhu
caihui zhu
JXJianzhi Xu
Jianzhi Xu
Hui ZhaoHui Zhao
Hui Zhao
Jian QiuJian Qiu
Jian Qiu
Kefu LiuKefu Liu
Kefu Liu
The success rate of the electrosurgical high-frequency electric field welding technique lies in reasonable control of the welding time. However, the final impedance value used to control the welding time varies due to differences in tissue size and the welding method during the welding process. This study aims to introduce a new reference indicator not limited by impedance size from dynamic impedance to achieve an adequate weld strength with minimal thermal damage, providing feedback on the tissue welding effect in medical power supplies. End-to-end anastomosis experiments were conducted with porcine small intestine tissue under seven levels of compression pressure. The dynamic impedance changes were analyzed, combined with compression pressure, temperature, moisture, and collagen during welding. The welding process was divided into three stages according to the dynamic impedance, with impedance decreasing in Period Ⅰ and impedance increasing in Period Ⅲ. Period Ⅲ was the key to high-strength connections due to water evaporation and collagen reorganization. The dynamic impedance ratio is defined as the final impedance divided by the minimum impedance, and successful welding would be predicted when detecting the dynamic impedance ratio over 4 (n = 70, p < 0.001). Dynamic impedance monitoring can be used as a macroscopic real-time prediction of the anastomosis effect.

13 November 2022 in Biomolecules
Verified
Journal Article
Open access
PDF file
CZcaihui zhu
caihui zhu
LYLi Yin
Li Yin
JXJianzhi Xu
Jianzhi Xu
XYXingjian Yang
Xingjian Yang
HWhao wang
hao wang
Kefu LiuKefu Liu
Kefu Liu
High-frequency electric field welding-induced tissue fusion has been explored as an advanced surgical method for intestinal anastomoses; however, intrinsic mechanisms remain unclear. The aim of this study was to investigate microcosmic changes of collagen within the fusion area, with various parameters. Ex vivo small intestine was fused with mucosa–mucosa. Four levels of compressive pressure (100 kPa, 150 kPa, 200 kPa, 250 kPa) were applied for 10 s in order to fuse the colons under a power level of 140 W. Then, collagen fibers of the fusion area were examined by fibrillar collagen alignment and TEM. Three levels of power (90 W, 110 W, 140 W) and three levels of time (5 s, 10 s, 20 s) were applied in order to fuse colons at 250 kPa, and then collagen within the fusion area was examined by Raman spectroscopy. Fibrillar collagen alignment analysis showed that with the increase in compression pressure, alignment of the collagen in the fusion area gradually increased, and the arrangement of collagen fibers tended to be consistent, which was conducive to the adhesion of collagen fibers. TEM showed that pressure changed the distribution and morphology of collagen fibers. Raman spectroscopy showed that increased power and time within a certain range contributed to collagen cross linking. Peak positions of amide I band and amide III band changed. These results suggested that higher power and a longer amount of time resulted in a decrease in non-reducible cross links and an increase in reducible cross links. Compression pressure, power, and time can affect the state of collagen, but the mechanisms are different. Compressive pressure affected the state of collagen by changing its orientation; power and time denatured collagen by increasing temperature and improved the reducible cross linking of collagen to promote tissue fusion.

10 September 2023 in Electronics
Verified
Journal Article
Open access
PDF file
LCLei Chen
Lei Chen
CZcaihui zhu
caihui zhu
JZJiaming Zheng
Jiaming Zheng
Jian QiuJian Qiu
Jian Qiu
Hui ZhaoHui Zhao
Hui Zhao
Kefu LiuKefu Liu
Kefu Liu
With the increasing and deepening application of high-voltage nanosecond solid-state pulse generators in biological, industrial, and environmental fields, the development of existing pulse generators faces many challenges, such as fixed pulse shapes, the usage of isolated driver power supplies, lower power density, and limited output electrical performance. Hence, a novel high-frequency multilevel nanosecond modular solid-state Marx modulator (SSMM) based on discrete magnetic coupling gate drivers is proposed. The gate voltage of the two MOSFETs can be rapidly synchronized at a high repetition frequency to achieve an amplitude-controlled gate voltage within 100 ns. The feasibility of the driver was verified by PSpice simulation and prototype testing. Moreover, a stackable SSMM module (S2M3) structure is proposed to solve the problem of common-mode interference conducted through the driver, which improves the reusability, scalability, and redundancy of modulators. The characteristic parameters of the developed 14-stage S2M3 are as follows: an output voltage amplitude of 5.45 kV with a 100 ns–50 ms width, a minimum rise time of approximately 18 ns, and a continuous repetition frequency of 100 kHz. S2M3 has the ability to change the pulse shape, and the pulse frequency can reach 2.8 MHz within the burst.

11 October 2024 in International Journal of Surgery
Verified
Journal Article
Open access
CZcaihui zhu
caihui zhu
YNYuyan Na
Yuyan Na
ZYZhengqing Yan
Zhengqing Yan
XCXiujun Cheng
Xiujun Cheng
PXPengyao Xie
Pengyao Xie
Kefu LiuKefu Liu
Kefu Liu
To investigate the effect of High-Frequency Electric Welding (HFEW) on intestinal tissue healing, we performed end-to-end anastomosis experiments in New Zealand rabbits. Within one week post-surgery, animals exhibited normal vital signs, replaced necrotic tissue with healthy collagen, and showed improved tissue strength while inflammation decreased. By day 60, tissue pathology and function fully recovered, resembling normal tissue. Healing at the anastomotic site occurred in three phases: immediate adhesion, inflammation, and remodeling, with macrophages crucial for phagocytosis and regeneration of necrotic tissue. This study enhances understanding of HFEW’s healing mechanisms and supports further preclinical investigations. Export