Li Yin

Ms. Li Yin

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2017 in Translational Oncology
Verified
Journal Article
Open access
FZFengguang Zhang
Fengguang Zhang
JQJinrong Qu
Jinrong Qu
HZHongkai Zhang
Hongkai Zhang
HLHui Liu
Hui Liu
JQJianjun Qin
Jianjun Qin
HLHailiang Li
Hailiang Li
To compare the T staging of potentially resectable esophageal cancer using free-breathing radial VIBE (r-VIBE) and breath-hold Cartesian VIBE (C-VIBE), with pathologic confirmation of the T stage. Fifty patients with endoscopically proven esophageal cancer and indeterminate T1/T2/T3 stage by CT scan were examined on a 3-T scanner. The MRI protocol included C-VIBE at 150 seconds post-IV contrast, immediately followed by a work-in-progress r-VIBE with identical spatial resolution (1.1 mm × 1.1 mm × 3.0 mm). Two independent readers assigned a T stage on MRI according to the 7th edition of UICC-AJCC TNM Classification, and postoperative pathologic confirmation was considered the gold standard. Interreader agreement was also calculated. The T staging agreement between both VIBE techniques and postoperative pathologic T staging was 52% (26/50) for C-VIBE, 80% (40/50) for r-VIBE for reader 1, and 50% (25/50), 82% (41/50) for reader 2, respectively. For the esophageal cancer with invading lamina propria, muscularis mucosae, or submucosa (T1 stage), r-VIBE achieved 86% (12/14) agreement for both readers 1 and 2. For invasion of muscularis propria (T2 stage), r-VIBE achieved 83% (25/30) for both readers 1 and 2, whereas for the invasion of adventitia (T3 stage), r-VIBE could only achieve agreement in 50% (3/6) and 67% (4/6) for readers 1 and 2, respectively. Contrast-enhanced free-breathing r-VIBE is superior to breath-hold CVIBE in T staging of potentially resectable esophageal cancer, especially for T1 and T2.

31 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
HWhao wang
hao wang
XYXingjian Yang
Xingjian Yang
NMNaerzhuoli Madeniyeti
Naerzhuoli Madeniyeti
Jian QiuJian Qiu
Jian Qiu
CZcaihui zhu
caihui zhu
Kefu LiuKefu Liu
Kefu Liu
In clinical surgery, high frequency electric welding is routinely utilized to seal and fuse soft tissues. This procedure denatures collagen by electrothermal coupling, resulting in the formation of new molecular crosslinks. It is critical to understand the temperature distribution and collagen structure changes during welding in order to prevent thermal damage caused by heat generated during welding. In this study, a method combining optical measurement and simulation was presented to evaluate the temperature distribution of vascular tissue during welding, with a fitting degree larger than 97% between simulation findings and measured data. Integrating temperature distribution data, strength test data, and Raman spectrum data, it is discovered that optimal parameters exist in the welding process that may effectively prevent thermal damage while assuring welding strength.

13 November 2022 in Biomolecules
Verified
Journal Article
Open access
PDF file
CZcaihui zhu
caihui zhu
LYLi Yin
Li Yin
JXJianzhi Xu
Jianzhi Xu
XYXingjian Yang
Xingjian Yang
HWhao wang
hao wang
Kefu LiuKefu Liu
Kefu Liu
High-frequency electric field welding-induced tissue fusion has been explored as an advanced surgical method for intestinal anastomoses; however, intrinsic mechanisms remain unclear. The aim of this study was to investigate microcosmic changes of collagen within the fusion area, with various parameters. Ex vivo small intestine was fused with mucosa–mucosa. Four levels of compressive pressure (100 kPa, 150 kPa, 200 kPa, 250 kPa) were applied for 10 s in order to fuse the colons under a power level of 140 W. Then, collagen fibers of the fusion area were examined by fibrillar collagen alignment and TEM. Three levels of power (90 W, 110 W, 140 W) and three levels of time (5 s, 10 s, 20 s) were applied in order to fuse colons at 250 kPa, and then collagen within the fusion area was examined by Raman spectroscopy. Fibrillar collagen alignment analysis showed that with the increase in compression pressure, alignment of the collagen in the fusion area gradually increased, and the arrangement of collagen fibers tended to be consistent, which was conducive to the adhesion of collagen fibers. TEM showed that pressure changed the distribution and morphology of collagen fibers. Raman spectroscopy showed that increased power and time within a certain range contributed to collagen cross linking. Peak positions of amide I band and amide III band changed. These results suggested that higher power and a longer amount of time resulted in a decrease in non-reducible cross links and an increase in reducible cross links. Compression pressure, power, and time can affect the state of collagen, but the mechanisms are different. Compressive pressure affected the state of collagen by changing its orientation; power and time denatured collagen by increasing temperature and improved the reducible cross linking of collagen to promote tissue fusion.

28 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LYLi Yin
Li Yin
CZcaihui zhu
caihui zhu
JXJianzhi Xu
Jianzhi Xu
Hui ZhaoHui Zhao
Hui Zhao
Jian QiuJian Qiu
Jian Qiu
Kefu LiuKefu Liu
Kefu Liu
The success rate of the electrosurgical high-frequency electric field welding technique lies in reasonable control of the welding time. However, the final impedance value used to control the welding time varies due to differences in tissue size and the welding method during the welding process. This study aims to introduce a new reference indicator not limited by impedance size from dynamic impedance to achieve an adequate weld strength with minimal thermal damage, providing feedback on the tissue welding effect in medical power supplies. End-to-end anastomosis experiments were conducted with porcine small intestine tissue under seven levels of compression pressure. The dynamic impedance changes were analyzed, combined with compression pressure, temperature, moisture, and collagen during welding. The welding process was divided into three stages according to the dynamic impedance, with impedance decreasing in Period Ⅰ and impedance increasing in Period Ⅲ. Period Ⅲ was the key to high-strength connections due to water evaporation and collagen reorganization. The dynamic impedance ratio is defined as the final impedance divided by the minimum impedance, and successful welding would be predicted when detecting the dynamic impedance ratio over 4 (n = 70, p < 0.001). Dynamic impedance monitoring can be used as a macroscopic real-time prediction of the anastomosis effect.

20 July 2016
Verified
Journal Article
Open access
PDF file
WFWentao Fang
Wentao Fang
JFJianhua Fu
Jianhua Fu
YSYi Shen
Yi Shen
YWYucheng Wei
Yucheng Wei
LTLijie Tan
Lijie Tan
MTMembers of the Chinese Alliance for Research in Thymomas
Members of the Chinese Alliance for Research in Thymomas
DOI: 10.3779/j.issn.1009-3419.2016.07.02