Current source inverters (CSIs) use inductors as the major component to store energy. Compared with voltage source inverters (VSIs), CSIs have two advantages: 1. They can avoid the converter failure caused by capacitor failures, and 2. The load current does not increase with load mutation or even short-circuit failure. Therefore, CSIs can be a promising technology for EV charging. However, the waveforms, parameter design procedure, and power efficiency are still unclear. Therefore, it is unclear if CSIs are suitable for EV chargers. This article derives the closed-loop equations of the critical components, including the inductor current waveforms and the voltage ripple. Especially, the load over-voltage phenomenon is derived and verified to further ensure the reliability of the CSI system. Based on the derived equations and reliability requirements, the parameter design procedure is proposed. The power efficiency of both the Si- and SiC-based converters are derived and compared to remove the barrier of applying CSIs in EV chargers in the industry. Our simulations and experiments verify the correctness of the system modeling, over-voltage phenomenon, and power efficiency. All the simulation files (using PLECS) and calculation files (using MATLAB) are attached for the readers to verify and/or further modify.
In clinical surgery, high frequency electric welding is routinely utilized to seal and fuse soft tissues. This procedure denatures collagen by electrothermal coupling, resulting in the formation of new molecular crosslinks. It is critical to understand the temperature distribution and collagen structure changes during welding in order to prevent thermal damage caused by heat generated during welding. In this study, a method combining optical measurement and simulation was presented to evaluate the temperature distribution of vascular tissue during welding, with a fitting degree larger than 97% between simulation findings and measured data. Integrating temperature distribution data, strength test data, and Raman spectrum data, it is discovered that optimal parameters exist in the welding process that may effectively prevent thermal damage while assuring welding strength.
High-frequency electric field welding-induced tissue fusion has been explored as an advanced surgical method for intestinal anastomoses; however, intrinsic mechanisms remain unclear. The aim of this study was to investigate microcosmic changes of collagen within the fusion area, with various parameters. Ex vivo small intestine was fused with mucosa–mucosa. Four levels of compressive pressure (100 kPa, 150 kPa, 200 kPa, 250 kPa) were applied for 10 s in order to fuse the colons under a power level of 140 W. Then, collagen fibers of the fusion area were examined by fibrillar collagen alignment and TEM. Three levels of power (90 W, 110 W, 140 W) and three levels of time (5 s, 10 s, 20 s) were applied in order to fuse colons at 250 kPa, and then collagen within the fusion area was examined by Raman spectroscopy. Fibrillar collagen alignment analysis showed that with the increase in compression pressure, alignment of the collagen in the fusion area gradually increased, and the arrangement of collagen fibers tended to be consistent, which was conducive to the adhesion of collagen fibers. TEM showed that pressure changed the distribution and morphology of collagen fibers. Raman spectroscopy showed that increased power and time within a certain range contributed to collagen cross linking. Peak positions of amide I band and amide III band changed. These results suggested that higher power and a longer amount of time resulted in a decrease in non-reducible cross links and an increase in reducible cross links. Compression pressure, power, and time can affect the state of collagen, but the mechanisms are different. Compressive pressure affected the state of collagen by changing its orientation; power and time denatured collagen by increasing temperature and improved the reducible cross linking of collagen to promote tissue fusion.
The inductor-based and capacitor-free bipolar pulse converter can be applied to electric vehicle charging and realize an efficient and reliable charging-control strategy. Inductor-based converters can avoid the converter failure caused by the failure of energy storage capacitors and improve the reliability. An overvoltage protection scheme based on active clamping topology is used to protect this converter when the load impedance is too large. This overvoltage protection can take effect in an extremely short time (~50 ns) with little energy wasted. Furthermore, mathematical analyses of the proposed topology are presented and simulations based on LTspice are made, showing the feasibility and reliability of this circuit. Moreover, calculation of the power loss on MOSFETs is presented. A 201 W prototype converter with an efficiency of 83% is presented, and experimental results show that the converter can work reliably. This manuscript also proves the feasibility and application prospect of using this current-source-based converter for EV charging.