Graphene-based metamaterials have been widely applied in optoelectronic devices, optical modulators, and chemical sensors due to the outstanding tunability and optical response in the terahertz (THz) region. Here, tunable THz metamaterial absorbers based on patterned graphene are designed, fabricated, and modulated. The proposed metamaterial absorbers are constructed by the top layer of patterned graphene arrays and the aluminum (Al) film separated by polyimide (PI). The different THz absorption spectra can be acquired by changing the patterns of graphene. In order to verify the simulation results, a series of tests were conducted by THz time-domain spectrometer (THz-TDS) systems. The proposed absorbers are able to be insensitive to the angle of the incident wave. Besides, chemical doping is applied to turn the Fermi level of graphene and the absorption performance is promoted with the increase of the Fermi level. The experimental results have been demonstrated to have associated resonant peaks with the simulation results. The aim of this paper is to exhibit a systematic study on graphene-based THz metamaterial absorbers, including the simulation and experiments. By comparing the simulation and experimental results, it is useful to clarify the relevant theories and manufacturing processes. The work will provide a further step in the development of high-performance terahertz devices, including tunable absorbers, sensors, and electro-optic switches.
The substrate impurities scattering will lead to unstable temperature-sensitive behavior and poor linearity in graphene temperature sensors. And this can be weakened by suspending the graphene structure. Herein, we report a graphene temperature sensing structure, with suspended graphene membranes fabricated on the cavity and non-cavity SiO2/Si substrate, using monolayer, few-layer, and multilayer graphene. The results show that the sensor provides direct electrical readout from temperature to resistance transduction by the nano piezoresistive effect in graphene. And the cavity structure can weaken the substrate impurity scattering and thermal resistance effect, which results in better sensitivity and wide-range temperature sensing. In addition, monolayer graphene is almost no temperature sensitivity. And the few-layer graphene temperature sensitivity, lower than that of the multilayer graphene cavity structure (3.50%/°C), is 1.07%/°C. This work demonstrates that piezoresistive in suspended graphene membranes can effectively enhance the sensitivity and widen the temperature sensor range in NEMS temperature sensors.
28 February 2022 in Science China Technological Sciences
The development of a facile surface-enhanced Raman scattering (SERS) sensor for the on-site detection of trace molecules in liquid phase is a compelling need. In this paper, a three-dimensional (3D) dendritic Au–Ag nanostructure was constructed by a two-step electro displacement reaction in a capillary tube for the on-site liquid phase detection of trace molecules. The multiplasmon resonance mechanism of the dendritic Au–Ag structure was simulated using the finite-difference time domain (FDTD) method. It was confirmed that the highly branched 3D structure promoted the formation of high-density “hot spots” and interacted with the gold nanoparticles at the dendrite tip, gap, and surface to maximize the spatial electric field, which allowed for high signal intensification to be observed. More importantly, the unique structure of the capillary made it possible to achieve the on-site detection of trace molecules in liquids. Using Rhodamine 6G (R6G) solution as a model molecule, the 3D dendritic Au–Ag substrate exhibited a high detection sensitivity (10−13 mol/L). Furthermore, the developed sensor was applied to the detection of antibacterial agents, ciprofloxacin (CIP), with clear Raman characteristic peaks observed even at concentrations as low as 10−9 mol/L. The results demonstrated that the 3D dendritic Au–Ag sensor could successfully realize the rapid on-site SERS detection of trace molecules in liquids, providing a promising platform for ultrasensitive and on-site liquid sample analysis.
Few-layer chemical vapor deposition (CVD) graphene was successively wet-transferred on a magnetron sputtering Ag/TiO2 film to develop a recyclable surface-enhanced Raman scattering (SERS) substrate with high sensitivity, stability, and reproducibility owing to the passivation of graphene, the SERS function of Ag and the photocatalytic activity of TiO2. The detection limit of rhodamine 6G (R6G) for the graphene/Ag/TiO2 nanocomposite could be lowered to 10−11 M, and its enhancement factor was 3.75 × 106. Moreover, a good linear response was observed between Raman intensity and R6G concentration with a fitted curve (R2 = 0.98), demonstrating that the prepared substrate can estimate the concentration of probe molecules for practical testing applications. Importantly, the homogeneity of the substrate structure and the passivation protection of the graphene layer resulted in excellent reproducibility (relative standard deviation less than 9%) and stability (the substrate maintained good SERS activity after 30 days of exposure to air) of the SERS substrate. Besides, the photocatalytic properties of TiO2 could eliminate the Raman signal of methylene blue (MB) efficiently and make this substrate recyclable. After being reused five times, its excellent SERS performance was still retained. Thus, the successful preparation of this composite structure opens up new avenues for the construction of high-performance multilayer composite SERS substrate, which is expected to become a new type of ultra-sensitive, highly stable, and reusable analytical tool.
The seeking of resonator with high Q and low insertion loss is attractive for critical sensing scenes based on the surface acoustic wave (SAW). In this work, 128° YX LiNbO3-based SAW resonators were utilized to optimize the output performance through IDT structure parameters. Once the pairs of IDTs, the acoustic aperture, the reflecting grid logarithm, and the gap between IDT and reflector are changed, a better resonance frequency of 224.85 MHz and a high Q of 1364.5 were obtained. All the results demonstrate the structure parameters design is helpful for the performance enhancement with regard to SAW resonators, especially for designing and fabricating high-Q devices.