The installed flow field for a variable pitch fan (VPF) operating in reverse thrust for the complete aircraft landing run is described in this paper. To do this, a VPF design to generate reverse thrust by reversing airflow direction is developed for a representative 40,000 lbf modern high bypass ratio engine. Thereafter, to represent the actual flow conditions that the VPF would face, an engine model that includes the nacelle, core inlet splitter, outlet guide vanes, bypass nozzle, core exhaust duct, aft-body plug, and core nozzle is designed. The engine model with the VPF is attached to a representative airframe in landing configuration to include the effects of installation. A rolling ground plane that mimics the runway during the landing run is also included to complete the model definition. Three-dimensional (3D) Reynolds-averaged Navier–Stokes (RANS) solutions are carried out for two different VPF stagger angle settings and rotational speeds to obtain the fan flow field. The dynamic installed VPF flow field is characterized by the interaction of the freestream and the reverse stream flows. The two streams meet in a shear layer in the fan passages and get deflected radially outward before turning back onto themselves. The flow field changes with stagger setting, fan rotational speed, and the aircraft landing speed because of the consequent changes in the momentum of the two streams. The description of the installed VPF flow field as generated in this study is necessary to (a) qualify VPF designs that are typically designed by considering only the uninstalled static flow field and (b) choose the VPF operating setting for different stages of the aircraft landing run.
The resultant forces with a reverse thrust variable pitch fan (VPF) during the aircraft landing run are computed from the installed reverse thrust flow field obtained from an airframe-engine-VPF research model. The research model features a reverse flow capable VPF design in a future, geared, high-bypass ratio 40,000 lbf engine as installed onto a twin-engine airframe in landing configuration, complete with a rolling ground plane to mimic the runway. The reverse thrust flow field during the aircraft landing run is obtained from the three-dimensional RANS/URANS solutions of the model. The evolution of the installed dynamic reverse thrust flow field is characterized by the interaction of the VPF-induced reverse flow with the freestream. Several flow features like reverse flow wash-down by the freestream, external swirling helical flow development, pylon flow obstruction, 180 deg flow turn into the engine, subsequent separated flows, wake interactions, and multipass recirculating flows are observed. The resultant airframe forces due to the reverse thrust flow field are estimated by adaptations of momentum-based far-field and near-field methods. In the active thrust reverser engagement regime of 140 to 40 knots, the VPF generates a sufficient axial airframe decelerating force in the range of 45% to 8% of maximum takeoff thrust. A drag decomposition study and a notional “blocked-fan” analysis are described to understand the stack-up of the axial decelerating force. Additionally, the resultant force has a landing speed-dependent lateral force component because of the pylon obstruction-induced flow nonuniformity. A beneficial downforce component due to upward deflection of streamlines is also observed. The quantification of the resultant forces from the baseline installed airframe-engine-VPF reverse thrust flow field is a necessary step to explore the feasibility of the VPF reverse thrust system for future efficient turbofan architectures, understand force generation mechanisms, and to identify areas for subsequent design improvement.
5 October 2021 in Journal of Engineering for Gas Turbines and Power
The installed variable pitch fan (VPF) reverse thrust flow field is obtained from the flow solution of an integrated airframe-engine research model for the complete reverser engagement regime during the aircraft landing run from 140 knots to 40 knots. The model includes a twin-engine airframe, complete flow path representation of a future 40 000 lbf high bypass ratio geared turbofan engine, and a bespoke reverse flow-capable VPF design. The reverse thrust flow field, at all speeds, indicates that the reverse flow out of the nacelle inlet is washed downstream by the freestream toward the engine exit regions. Consequently, reverse flow enters the engine through the bypass nozzle from a 180 deg turn of the washed-down stream. This results in a region of circumferentially varying separated flow at the nozzle lip that acts as a blockage to the reverse flow entry into the engine. To mitigate the blockage issue, smooth guidance of the reverse flow into the engine to avoid separation can be achieved by using an inflatable rubber lip that would define a bell-mouth-like geometric feature with a round radius at the nacelle exit region. In nominal engine operation, the rubber lip would be stowed flush within the contours of the optimized nacelle surface. The design space of the rubber lip is studied by considering different rounding radii and locations of the turn radius with respect to the nacelle trailing edge. The choices of the design parameters are chosen by considering the nacelle edge thickness, inflation air volume requirement, weight, and thickness of support structures. The effect of these designs on the reverse thrust flow field is studied by incorporating the designs into the integrated model, with realistic installation-related restrictions. It is observed that a rounding radius of 0.1× nacelle length is sufficient to reduce the blockage and increase the ingested reverse flow by 47% to 18% in the 140–40 knots landing speed range. The inflatable rubber lip represents a design modification that can aid in the improvement of VPF reverse thrust operation, in cases where an augmentation of reverse thrust capability over the baseline is desired.
The effectiveness of acoustic excitation as a means of flow control at high Reynolds number turbulent flows is investigated numerically by using improved delayed detached eddy simulations (IDDES). Previous studies on low Reynolds number laminar flows have shown that acoustic excitation can substantially suppress flow separation for specific effective frequency and amplitude ranges. However, the effect of acoustic excitation on higher Reynolds number turbulent flow separation has not yet been explored due to limitations on appropriate fidelity computational methods or experimental facility constraints. Therefore, this paper addresses this research gap. A NACA0015 airfoil profile at 1 × 106 Reynolds number based on the airfoil chord length is used for the investigations. Acoustic excitation is applied to the baseline flow field in the form of transient boundary conditions at the computational domain inlet. A parametric study revealed that the effective sound frequency range shows a Gaussian distribution around the frequency of the dominant disturbances in the baseline flow. A maximum of ∼43% increase in lift-to-drag ratio is observed for the most effective excitation frequency F+=1.0 at a constant excitation amplitude of Am=1.8%. The effect of excitation amplitude follows an asymptotic trend with a maximum effective excitation amplitude above which the gains are not significant. A fully reattached flow is observed for the highest excitation level considered (Am=10%) that results in ∼120% rise in airfoil lift-to-drag coefficient. Overall, the findings of the current work demonstrate the higher Reynolds number effectiveness of acoustic excitation on separated turbulent flows, thereby paving the way for application in realistic flow scenarios observed in aircraft and gas turbine engine flow fields.
Boundary layer pumps, although attractive due to their compactness, robustness and multi-fluid and phase-handling capability, have been reported to have low experimental efficiencies despite optimistic predictions from analytical models. A lower-order flow-physics-based analytical model that can be used as a 1D design code for sizing and predicting pump performance is described. The rotor component is modelled by means of the Navier–Stokes equations as simplified using velocity profiles in the inter-disk gap, while the volute is modelled using kinetic-energy-based coefficients inspired by centrifugal pumps. The code can predict the rotor outlet and overall pump pressure ratio with an around 3% and 10% average error, respectively, compared to the reference experimental data for a water pump. Moreover, 3D RANS flow-field explorations of the rotor are carried out for different inter-disk gaps to provide insights concerning the improvement of the 1D design code for the better prediction of the overall pump performance. Improvements in volute loss modelling through the inclusion of realistic flow properties at the rotor outlet rather than the detailed resolution of the velocity profiles within the rotor are suggested as guidelines for improved predictions. Such improved design codes could close the gap between predictions and experimental values, thereby paving the way for the appropriate sizing of boundary layer pumps for several applications, including aircraft thermal management.