Guillermo Prieto-Avalos

Dr. Guillermo Prieto-Avalos

Instituto Tecnologico de Orizaba, Orizaba, Veracruz, Mexico
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Guillermo Prieto-AvalosGuillermo Prieto-Avalos
Guillermo Prieto-Avalos
NRNancy Aracely Cruz Ramos
Nancy Aracely Cruz Ramos
GAGiner Alor-Hernandez
Giner Alor-Hernandez
José Luis Sánchez-CervantesJosé Luis Sánchez-Cervantes
José Luis Sánchez-Cervantes
LRLisbeth Rodriguez-Mazahua
Lisbeth Rodriguez-Mazahua
Luis Rolando Guarneros-NolascoLuis Rolando Guarneros-Nolasco
Luis Rolando Guarneros-Nolasco
Cardiovascular diseases (CVDs) are the leading cause of death globally. An effective strategy to mitigate the burden of CVDs has been to monitor patients’ biomedical variables during daily activities with wearable technology. Nowadays, technological advance has contributed to wearables technology by reducing the size of the devices, improving the accuracy of sensing biomedical variables to be devices with relatively low energy consumption that can manage security and privacy of the patient’s medical information, have adaptability to any data storage system, and have reasonable costs with regard to the traditional scheme where the patient must go to a hospital for an electrocardiogram, thus contributing a serious option in diagnosis and treatment of CVDs. In this work, we review commercial and noncommercial wearable devices used to monitor CVD biomedical variables. Our main findings revealed that commercial wearables usually include smart wristbands, patches, and smartwatches, and they generally monitor variables such as heart rate, blood oxygen saturation, and electrocardiogram data. Noncommercial wearables focus on monitoring electrocardiogram and photoplethysmography data, and they mostly include accelerometers and smartwatches for detecting atrial fibrillation and heart failure. However, using wearable devices without healthy personal habits will cause disappointing results in the patient’s health.

31 December 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Guillermo Prieto-AvalosGuillermo Prieto-Avalos
Guillermo Prieto-Avalos
LSLaura Nely Sánchez-Morales
Laura Nely Sánchez-Morales
GAGiner Alor-Hernandez
Giner Alor-Hernandez
José Luis Sánchez-CervantesJosé Luis Sánchez-Cervantes
José Luis Sánchez-Cervantes
Neurodegenerative diseases (NDDs) are among the 10 causes of death worldwide. The effects of NDDs, including irreversible motor impairments, have an impact not only on patients themselves but also on their families and social environments. One strategy to mitigate the pain of NDDs is to early identify and remotely monitor related motor impairments using wearable devices. Technological progress has contributed to reducing the hardware complexity of mobile devices while simultaneously improving their efficiency in terms of data collection and processing and energy consumption. However, perhaps the greatest challenges of current mobile devices are to successfully manage the security and privacy of patient medical data and maintain reasonable costs with respect to the traditional patient consultation scheme. In this work, we conclude: (1) Falls are most monitored for Parkinson’s disease, while tremors predominate in epilepsy and Alzheimer’s disease. These findings will provide guidance for wearable device manufacturers to strengthen areas of opportunity that need to be addressed, and (2) Of the total universe of commercial wearables devices that are available on the market, only a few have FDA approval, which means that there is a large number of devices that do not safeguard the integrity of the users who use them.

17 October 2018 in IEEE Access
Verified
Journal Article
Open access
Guillermo Prieto-AvalosGuillermo Prieto-Avalos
Guillermo Prieto-Avalos
KCKatherine Caillahua Castillo
Katherine Caillahua Castillo
DMDaniela Martinez
Daniela Martinez
GGGuillermo Galaviz
Guillermo Galaviz
In this work, the evaluation of a spectrum sensing strategy based on the Frequency Domain Entropy applied to cognitive radio networks is presented. Entropy estimation is performed using Bartlett periodogram. A tradeoff between variance and the spectral resolution for Bartlett periodogram is figured out. This tradeoff affects the probability of detection and false alarm of the spectrum sensing strategy under environments with low signal-to-noise ratio and noise uncertainty. The Entropy detector is optimal when the product of the number of segments and the number of points used is equal to the number of available samples of the received signal.

7 July 2023 in Mathematics
Verified
Journal Article
Open access
PDF file
Luis Rolando Guarneros-NolascoLuis Rolando Guarneros-Nolasco
Luis Rolando Guarneros-Nolasco
GAGiner Alor-Hernandez
Giner Alor-Hernandez
Guillermo Prieto-AvalosGuillermo Prieto-Avalos
Guillermo Prieto-Avalos
José Luis Sánchez-CervantesJosé Luis Sánchez-Cervantes
José Luis Sánchez-Cervantes
Liver diseases are a widespread and severe health concern, affecting millions worldwide. Non-alcoholic fatty liver disease (NAFLD) alone affects one-third of the global population, with some Latin American countries seeing rates exceeding 50%. This alarming trend has prompted researchers to explore new methods for identifying those at risk. One promising approach is using Machine Learning Algorithms (MLAs), which can help predict critical factors contributing to liver disease development. Our study examined nine different MLAs across four datasets to determine their effectiveness in predicting this condition. We analyzed each algorithm’s performance using five important metrics: accuracy, precision, recall, f1-score, and roc_auc. Our results showed that these algorithms were highly effective when used individually and as part of an ensemble modeling technique such as bagging or boosting. We identified alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), and albumin as the top four attributes most strongly associated with non-alcoholic fatty liver disease risk across all datasets. Gamma-glutamyl transpeptidase (GGT), hemoglobin, age, and prothrombin time also played significant roles. In conclusion, this research provides valuable insights into how we can better detect and prevent non-alcoholic fatty liver diseases by leveraging advanced machine learning techniques. As such, it represents an exciting opportunity for healthcare professionals seeking more accurate diagnostic tools while improving patient outcomes globally.

12 November 2025 in Hardware
Verified
Journal Article
Open access
PDF file
Jesús Elías Miranda-VegaJesús Elías Miranda-Vega
Jesús Elías Miranda-Vega
Erick Yandel Nuñez PatronErick Yandel Nuñez Patron
Erick Yandel Nuñez Patron
Guillermo Prieto-AvalosGuillermo Prieto-Avalos
Guillermo Prieto-Avalos
Wendy Flores-FuentesWendy Flores-Fuentes
Wendy Flores-Fuentes
Oleg SergiyenkoOleg Sergiyenko
Oleg Sergiyenko
RFRafael Ivan Ayala Figueroa
Rafael Ivan Ayala Figueroa
To support the understanding of cardiovascular monitoring and physiological signal processing, we present a portable, open-source photoplethysmography (PPG) acquisition platform developed for educational and research applications. The system is built entirely with commercial off-the-shelf components and centers around an ESP32 microcontroller, which performs high-speed analog signal acquisition at 500 samples per second, alongside real-time control, and wireless communication. A cross-platform, Python-based graphical user interface enables real-time signal visualization, peak detection, and the computation of heart rate variability (HRV) metrics, including RMSSD and SDNN, during offline analysis. All hardware and software resources are openly available to enable replication and further development. This project emphasizes accessibility, transparency, and hands-on learning in biomedical signal acquisition. System functionality is validated offline through controlled data collection from human subjects, demonstrating results consistent with established HRV benchmarks.

10 October 2026
Verified
Journal Article
Closed access
Jesús Elías Miranda-VegaJesús Elías Miranda-Vega
Jesús Elías Miranda-Vega
WGWendy García-González
Wendy García-González
VGVanessa López Gastelum
Vanessa López Gastelum
RFRafael Ivan Ayala Figueroa
Rafael Ivan Ayala Figueroa
Ricardo Eliu Lozoya-PonceRicardo Eliu Lozoya-Ponce
Ricardo Eliu Lozoya-Ponce
Guillermo Prieto-AvalosGuillermo Prieto-Avalos
Guillermo Prieto-Avalos
This paper presents a low-cost real-time photoplethysmography (PPG) monitoring platform based on an ESP32-S3 SuperMini, a MAX30102 sensor operating at 200 samples per second, and a desktop graphical user interface (GUI). The proposed system establishes Bluetooth Low Energy (BLE) communication between the embedded node and the PC interface to stream both infrared (IR) and red (RED) channels simultaneously. On the embedded side, the firmware acquires, packages, and transmits the raw PPG signals while estimating the heart rate in beats per minute (BPM) for each channel. On the desktop side, the GUI displays the received signals and the corresponding BPM values in real time, providing a practical and accessible monitoring environment. The main contribution is the integration of real-time dual-channel PPG acquisition, BLE transmission, embedded BPM estimation, desktop GUI visualization, and experimental validation within a single compact and low-cost platform. The proposed architecture is aimed at low-cost biomedical applications and offers a compact solution for signal acquisition, wireless communication, visualization, and basic physiological estimation. Experimental results show that the platform can reliably capture and transmit both channels, supporting its use as a foundation for future work on more advanced PPG processing and physiological monitoring applications. Furthermore, the system performance was validated by comparing the estimated heart rate against measurements obtained from two medical reference devices: a pulse oximeter and a digital sphygmomanometer. The results demonstrated good agreement between the measurements, supporting the feasibility of the proposed platform for non-invasive physiological monitoring applications.