Wendy García-González

Dr. Wendy García-González

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2023 in Entropy
Verified
Journal Article
Open access
PDF file
WGWendy García-González
Wendy García-González
Wendy Flores-FuentesWendy Flores-Fuentes
Wendy Flores-Fuentes
Oleg SergiyenkoOleg Sergiyenko
Oleg Sergiyenko
Julio Rodríguez-QuiñonezJulio Rodríguez-Quiñonez
Julio Rodríguez-Quiñonez
Jesús Elías Miranda-VegaJesús Elías Miranda-Vega
Jesús Elías Miranda-Vega
DHDaniel Hernández-Balbuena
Daniel Hernández-Balbuena
A novelty signal processing method is proposed for a technical vision system (TVS). During data acquisition of an optoelectrical signal, part of this is random electrical fluctuation of voltages. Information theory (IT) is a well-known field that deals with random processes. A method based on using of the Shannon Entropy for feature extractions of optical patterns is presented. IT is implemented in structural health monitoring (SHM) to augment the accuracy of optoelectronic signal classifiers for a metrology subsystem of the TVS. To enhance the TVS spatial coordinate measurement performance at real operation conditions with electrical and optical noisy environments to estimate structural displacement better and evaluate its health for a better estimation of structural displacement and the evaluation of its health. Five different machine learning (ML) techniques are used in this work to classify optical patterns captured with the TVS. Linear predictive coding (LPC) and Autocorrelation function (ACC) are for extraction of optical patterns. The Shannon entropy segmentation (SH) method extracts relevant information from optical patterns, and the model’s performance can be improved. The results reveal that segmentation with Shannon’s entropy can achieve over 95.33%. Without Shannon’s entropy, the worst accuracy was 33.33%.

12 November 2025 in Hardware
Verified
Journal Article
Open access
PDF file
Jesús Elías Miranda-VegaJesús Elías Miranda-Vega
Jesús Elías Miranda-Vega
Erick Yandel Nuñez PatronErick Yandel Nuñez Patron
Erick Yandel Nuñez Patron
Guillermo Prieto-AvalosGuillermo Prieto-Avalos
Guillermo Prieto-Avalos
Wendy Flores-FuentesWendy Flores-Fuentes
Wendy Flores-Fuentes
Oleg SergiyenkoOleg Sergiyenko
Oleg Sergiyenko
RFRafael Ivan Ayala Figueroa
Rafael Ivan Ayala Figueroa
To support the understanding of cardiovascular monitoring and physiological signal processing, we present a portable, open-source photoplethysmography (PPG) acquisition platform developed for educational and research applications. The system is built entirely with commercial off-the-shelf components and centers around an ESP32 microcontroller, which performs high-speed analog signal acquisition at 500 samples per second, alongside real-time control, and wireless communication. A cross-platform, Python-based graphical user interface enables real-time signal visualization, peak detection, and the computation of heart rate variability (HRV) metrics, including RMSSD and SDNN, during offline analysis. All hardware and software resources are openly available to enable replication and further development. This project emphasizes accessibility, transparency, and hands-on learning in biomedical signal acquisition. System functionality is validated offline through controlled data collection from human subjects, demonstrating results consistent with established HRV benchmarks.

24 March 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Jesús Elías Miranda-VegaJesús Elías Miranda-Vega
Jesús Elías Miranda-Vega
ADArnoldo Diaz-Ramírez
Arnoldo Diaz-Ramírez
Oleg SergiyenkoOleg Sergiyenko
Oleg Sergiyenko
WGWendy García-González
Wendy García-González
Wendy Flores-FuentesWendy Flores-Fuentes
Wendy Flores-Fuentes
Julio Rodríguez-QuiñonezJulio Rodríguez-Quiñonez
Julio Rodríguez-Quiñonez
Nowadays, artificial intelligence (AI) has revolutionized the industry and made it possible to develop systems that ensure safety in human-robot collaboration. Mobile and industrial robots need a point of reference in their orientation for avoiding obstacles. Device and sensor technologies, such as acoustic sensors, Global Positioning System (GPS), light detection and ranging (LiDAR), accelerometers, and digital cameras play an important role in providing high resolution and sensitivity to solve complex problems in the industry. However, their cost and the need of applying signal processing techniques to filter their signals may not offer the required reliability for critical applications, such as indoor localization methods for industrial robots. The optical scanning systems (OSS) are devices that can be used instead at a lower cost, compared to the costs of devices previously mentioned. Nevertheless, there is still the challenge of avoiding the filtering of the signal. In this paper, a method to determine the energy center from sensors of an OSS using AI techniques is introduced. It uses defuzzification algorithms to accomplish accuracy measurements for localization and navigation tasks. The advantage of this method is that it eliminates the need of using the filtering process. One of the main contributions of this work is that the results can be used to implement an accurate and efficient indoor localization system, which can be used by an autonomous vehicle, such as industrial robots. According to the statistical analysis carried out, the minimal difference between the real position and the position estimated by the OSS was 0.021°.

31 May 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Jesús Elías Miranda-VegaJesús Elías Miranda-Vega
Jesús Elías Miranda-Vega
Wendy Flores-FuentesWendy Flores-Fuentes
Wendy Flores-Fuentes
Oleg SergiyenkoOleg Sergiyenko
Oleg Sergiyenko
Julio Rodríguez-QuiñonezJulio Rodríguez-Quiñonez
Julio Rodríguez-Quiñonez
WGWendy García-González
Wendy García-González
DHDaniel Hernández-Balbuena
Daniel Hernández-Balbuena
This paper proposes an enhancement of a singular spectrum analysis (SSA) technique based on Hilbert Matrix (SSA-H) for autonomous navigation systems in a harsh environment. SSA is a technique that has caught the attention of different fields, and is used to extract trends and patterns in the time series domain. In this work, SSA-H is used to transform raw optical signals into meaningful information to build machine learning (ML) models. A technical vision system (TVS) with laser scanning for depth measurements is presented. According to the implementation of the TVS outdoors, some particular issues, such as interference radiation detected by its photodiode, can affect the system’s performance in determining depth measurements. This research extracts the laser beam patterns in a real environment to create ML models to solve the problem and address some of the technical challenges in a real environment. The main contribution of this work is designing an ML framework for recognizing the laser beam of the TVS based on SSA-H. Furthermore, a comparative analysis of ML techniques to discriminate sunlight interference was studied and compared with different configurations of SSA known in the literature. According to the results, the use of SSA-H can enhance the ML models such as Ensemble Learning (EL), Feed-Forward Neural Networks (FNN), Support Vector Machines (SVM), Naive Bayes (NB) in conjunction with autocorrelation function coefficients (ACC) as features.

30 July 2024 in Entropy
Verified
Journal Article
Open access
PDF file
ICIvan Yeniseysk Alba Corpus
Ivan Yeniseysk Alba Corpus
Wendy Flores-FuentesWendy Flores-Fuentes
Wendy Flores-Fuentes
Oleg SergiyenkoOleg Sergiyenko
Oleg Sergiyenko
Julio Rodríguez-QuiñonezJulio Rodríguez-Quiñonez
Julio Rodríguez-Quiñonez
Jesús Elías Miranda-VegaJesús Elías Miranda-Vega
Jesús Elías Miranda-Vega
JNJosé A. Núñez-López
José A. Núñez-López
This paper proposes an advancement in the application of a Technical Vision System (TVS), which integrates a laser scanning mechanism with a single light sensor to measure 3D spatial coordinates. In this application, the system is used to scan and digitalize objects using a rotating table to explore the potential of the system for 3D scanning at reduced resolutions. The experiments undertaken searched for optimal scanning windows and used statistical data filtering techniques and regression models to find a method to generate a 3D scan that was still recognizable with the least amount of 3D points, balancing the number of points scanned and time, while at the same time reducing effects caused by the particularities of the TVS, such as noise and entropy in the form of natural distortion in the resulting scans. The evaluation of the experimentation results uses 3D point registration methods, joining multiple faces from the original volume scanned by the TVS and aligning it to the ground truth model point clouds, which are based on a commercial 3D camera to verify that the reconstructed 3D model retains substantial detail from the original object. This research finds it is possible to reconstruct sufficiently detailed 3D models obtained from the TVS, which contain coarsely scanned data or scans that initially lack high definition or are too noisy.

10 October 2026
Verified
Journal Article
Closed access
Jesús Elías Miranda-VegaJesús Elías Miranda-Vega
Jesús Elías Miranda-Vega
WGWendy García-González
Wendy García-González
VGVanessa López Gastelum
Vanessa López Gastelum
RFRafael Ivan Ayala Figueroa
Rafael Ivan Ayala Figueroa
Ricardo Eliu Lozoya-PonceRicardo Eliu Lozoya-Ponce
Ricardo Eliu Lozoya-Ponce
Guillermo Prieto-AvalosGuillermo Prieto-Avalos
Guillermo Prieto-Avalos
This paper presents a low-cost real-time photoplethysmography (PPG) monitoring platform based on an ESP32-S3 SuperMini, a MAX30102 sensor operating at 200 samples per second, and a desktop graphical user interface (GUI). The proposed system establishes Bluetooth Low Energy (BLE) communication between the embedded node and the PC interface to stream both infrared (IR) and red (RED) channels simultaneously. On the embedded side, the firmware acquires, packages, and transmits the raw PPG signals while estimating the heart rate in beats per minute (BPM) for each channel. On the desktop side, the GUI displays the received signals and the corresponding BPM values in real time, providing a practical and accessible monitoring environment. The main contribution is the integration of real-time dual-channel PPG acquisition, BLE transmission, embedded BPM estimation, desktop GUI visualization, and experimental validation within a single compact and low-cost platform. The proposed architecture is aimed at low-cost biomedical applications and offers a compact solution for signal acquisition, wireless communication, visualization, and basic physiological estimation. Experimental results show that the platform can reliably capture and transmit both channels, supporting its use as a foundation for future work on more advanced PPG processing and physiological monitoring applications. Furthermore, the system performance was validated by comparing the estimated heart rate against measurements obtained from two medical reference devices: a pulse oximeter and a digital sphygmomanometer. The results demonstrated good agreement between the measurements, supporting the feasibility of the proposed platform for non-invasive physiological monitoring applications.