Tobias Zeus

Dr. Tobias Zeus

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2018 in European Journal of Medical Research
Verified
Journal Article
Open access
PDF file
KPKerstin Piayda
Kerstin Piayda
LKLaura Kleinebrecht
Laura Kleinebrecht
SAShazia Afzal
Shazia Afzal
RBRoland Bullens
Roland Bullens
IHIris ter Horst
Iris ter Horst
TZTobias Zeus
Tobias Zeus
A novel software (“Dynamic Coronary Roadmap”) was developed, which offers a real-time, dynamic overlay of the coronary tree on fluoroscopy. Once the roadmap has been automatically generated during angiography it can be used for navigation during percutaneous coronary interventions (PCI). As a feasibility study, we aimed to investigate the feasibility of real-time dynamic coronary roadmapping and consecutive coronary overlay during elective PCI. We studied 936 overlay runs, created following the same amount of angiographies, which were generated during 36 PCIs. Feasibility of dynamic coronary roadmapping was analyzed using a dedicated software tool. Roadmap quality (correct dynamic imaging of the vessels without relevant artefacts or missing parts) was distinguished from overlay quality (congruence of dynamic coronary roadmapping and coronary anatomy). Additionally, we assessed procedural success and the occurrence of major cardiac and cerebrovascular events (MACCE). Roadmap quality was defined as “fit for use” in 99.5%. In 97.4% of runs overlay quality was deemed “fit for use”. Overall, we observed low inter and intra observer variability (ICC R = 0.84 for roadmap quality and R = 0.75 for overlay quality). Procedural success rate was 100%. MACCE occurred in two (5.6%) patients during post-interventional in-hospital stay and were not software-related. Dynamic coronary roadmapping provides in > 98% of cases sufficient roadmap quality with an anatomically correct overlay of the coronary vessels with good inter and intra observer variability. Future randomized studies are warranted to test possible advantages like procedure time reduction and less consumption of contrast medium.

1 September 2021 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
PDF file
ODOspedale dell'Angelo
Ospedale dell'Angelo
GGGuglielmo Gallone
Guglielmo Gallone
WKWon-Keun Kim
Won-Keun Kim
JRJoerg Reifart
Joerg Reifart
VVVerena Veulemans
Verena Veulemans
FGFrancesco Giannini
Francesco Giannini
Background: An increased degree of aortic angulation (AA) represents a challenging feature for bioprosthesis positioning. Whether AA has an impact on procedural outcomes of contemporary self-expanding valves remains unsettled. The aim of this study was to evaluate the impact of AA on procedural outcomes of transcatheter aortic valve replacement with contemporary self-expanding valves. Methods: The HORSE (Horizontal Aorta in Transcatheter Self-Expanding Valves) is an international, retrospective registry including 3862 consecutive patients undergoing transcatheter aortic valve replacement with either Evolut R/PRO (n=1959) or ACURATE neo (n=1903) devices. Patients undergoing Evolut R 34 mm implantation were excluded as no comparable prosthesis size for ACURATE neo is available. AA was evaluated with preprocedural computed tomography, and its impact on device success was evaluated. Results: In the overall population, AA did not have any impact upon device success, also when adjusting for in-study outcome predictors (odds ratio for 1° increment, 0.99 [95% CI, 0.98–1.01], P =0.306). However, increased AA was associated with lower device success with use of the Evolut R/PRO valves (odds ratio, 0.97 [95% CI, 0.95–0.99]; P =0.004), but not the ACURATE neo valves (odds ratio, 1.00 [95% CI, 0.98–1.03], P =0.304). The best AA cutoff value predicting device success was 49° (47% of the study cohort). Among patients with AA≥49°, Evolut R/PRO valves were associated with lower device success as compared to the ACURATE neo valve (inverse probability weighting odds ratio, 0.62 [95% CI, 0.46–0.83]; P =0.002). Conclusions: Horizontal aorta, as defined by an AA ≥49°, is a common feature among transcatheter aortic valve replacement candidates and predicts device failure of the Evolut R/PRO valves, but not of the ACURATE neo valve. AA may be an effect modifier of the association between self-expanding valve type and device success.

2 June 2021 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Open access
PDF file
OMOliver Maier
Oliver Maier
KPKerstin Piayda
Kerstin Piayda
SAShazia Afzal
Shazia Afzal
APAmin Polzin
Amin Polzin
RWRalf Westenfeld
Ralf Westenfeld
VVVerena Veulemans
Verena Veulemans
Objectives: This meta‐analysis sought to assess predictors of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with focus on preprocedural multi‐slice computed tomography (MSCT) derived data.Background: Transcatheter aortic valve replacement (TAVR) has expanded to a well‐established treatment for severe symptomatic aortic stenosis at high and intermediate surgical risk. PPI after TAVR remains one of the most frequent procedure‐related complications and appears to be influenced by several factors.Methods: The authors conducted a literature search in PubMed/MEDLINE and EMBASE databases to identify studies that investigated preprocedural MSCT data and the rate of PPI following TAVR with new‐generation devices.Results: Ten observational studies (n = 2707) met inclusion criteria for the final analysis. PPI was performed in 387 patients (14.3%) after TAVR. Patients requiring PPI had a larger annulus perimeter (MD: 1.66 mm; p < .001) and a shorter membranous septum length (MD: −1.1 mm; p < .05). Concerning calcification distribution, patients with requirement for new pacemaker implantation showed increased calcification of the left coronary cusp (MD: 47.6 mm3; p < .001), and the total left ventricular outflow tract (MD: 24.42 mm3; p < .01). Lower implantation depth (MD: 0.95 mm; p < .05) and oversizing (MD: 1.52%; p < .05) were procedural predictors of PPI following TAVR.Conclusions: Besides the well‐known impact of electrocardiographic and procedure‐related factors on conduction disturbances, MSCT derived distribution of the aortic valve and left ventricular outflow tract calcification, as well as membranous septum length, are associated with an increased risk of PPI following TAVR.

20 February 2015 in Der Kardiologe
Verified
Journal Article
Closed access
PDF file
VSV. Schächinger
V. Schächinger
HNH. Nef
H. Nef
SAS. Achenbach
S. Achenbach
CBChristian Butter
Christian Butter
IDI. Deisenhofer
I. Deisenhofer
MKMalte Kelm
Malte Kelm

1 January 2023 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
Andrea ScottiAndrea Scotti
Andrea Scotti
SBSara Baggio
Sara Baggio
MPMatteo Pagnesi
Matteo Pagnesi
MBMarco Barbanti
Marco Barbanti
MAMarianna Adamo
Marianna Adamo
OIon behalf of the NEOPRO and NEOPRO-2 Investigators‡
on behalf of the NEOPRO and NEOPRO-2 Investigators‡
Background: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. Methods: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. Results: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1–4, 4.1% [2.8–6.3%], 3.7% [2.6–5.3%], 3.3% [2.4–4.9%], 2.9% [2.2–4.3%]; P <0.001) and more moderate or heavy valve calcification (Q1–4, 80%, 80%, 82%, 88%; P =0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1–4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P =0.023) and early safety (Q1–4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P <0.001), with fewer permanent pacemaker implantations (Q1–4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P =0.023) and residual mild or greater paravalvular leaks (Q1–4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P <0.001). Conclusions: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.

1 August 2019 in Mayo Clinic Proceedings
Verified
Journal Article
Closed access
ENEliano Navarese
Eliano Navarese
FAFelicita Andreotti
Felicita Andreotti
Michalina KołodziejczakMichalina Kołodziejczak
Michalina Kołodziejczak
WWWojciech Wańha
Wojciech Wańha
ALAlexander Lauten
Alexander Lauten
PBPaul A Bliden
Paul A Bliden