Wenjing Du

Wenjing Du

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2020 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
YAYousef Al-handarish
Yousef Al-handarish
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
TITobore Igbe
Tobore Igbe
SHShipeng Han
Shipeng Han
HLHui Li
Hui Li
Lei WangLei Wang
Lei Wang
Over the past few decades, tactile sensors have become an emerging field of research in both academia and industry. Recent advances have demonstrated application of tactile sensors in the area of biomedical engineering and opened up new opportunities for building multifunctional electronic skin (e‐skin) which is capable of imitating the human sense‐of‐touch for medical purposes. Analyses have shown that current smart tactile sensing technology has the advantages of high performance, low‐cost, time efficiency, and ease‐of‐fabrication. Tactile sensing systems have thus sufficiently matured for integration into several fields related to biomedical engineering. Furthermore, artificial intelligence has the potential for being applied in human‐machine interfacing, for instance, in medical robotic manipulation, especially during minimally invasive robotic surgery, where tactile sensing is usually a problem. In this survey, we present a comprehensive review of the state of the art of tactile sensors. We focus on the technical details of transduction mechanisms such as piezoresistivity, capacitance, piezoelectricity, and triboelectric and highlight the role of novel and commonly used materials in tactile sensing. In addition, we discuss contributions that have been reported in the field of biomedical engineering, which includes its present and future applications in building multifunctional e‐skins, human‐machine interfaces, and minimally invasive surgical robots. Finally, some challenges and notable improvements that have been made in the technical aspects of tactile sensing systems are reported.

12 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
WDWenke Duan
Wenke Duan
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
WDWenjing Du
Wenjing Du
JMJun Ma
Jun Ma
XCXing-Yu Chen
Xing-Yu Chen
Lei WangLei Wang
Lei Wang
Prior methods of patient care have changed in recent years due to the availability of minimally invasive surgical platforms for endovascular interventions. These platforms have demonstrated the ability to improve patients’ vascular intervention outcomes, and global morbidities and mortalities from vascular disease are decreasing. Nonetheless, there are still concerns about the long-term effects of exposing interventionalists and patients to the operational hazards in the cath lab, and the perioperative risks that patients undergo. For these reasons, robot-assisted vascular interventions were developed to provide interventionalists with the ability to perform minimally invasive procedures with improved surgical workflow. We conducted a thorough literature search and presented a review of 130 studies published within the last 20 years that focused on robot-assisted endovascular interventions and are closely related to the current gains and obstacles of vascular interventional robots published up to 2022. We assessed both the research-based prototypes and commercial products, with an emphasis on their technical characteristics and application domains. Furthermore, we outlined how the robotic platforms enhanced both surgeons’ and patients’ perioperative experiences of robot-assisted vascular interventions. Finally, we summarized our findings and proposed three key milestones that could improve the development of the next-generation vascular interventional robots.

1 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
LGLu Gan
Lu Gan
WDWen ke Duan
Wen ke Duan
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
WDWenjing Du
Wenjing Du
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
Lei WangLei Wang
Lei Wang
In this paper, a one-dimensional distal force sensor design is proposed for minimally invasive surgery based on fiber Bragg grating (FBG) sensing principle. The sensor is made with a miniaturized force-sensitive flexure within which an optical fiber is embedded. The former includes a spiral elastomer utilized for high axial force sensitivity, while the fiber includes dual FBGs that are tightly suspended around the distal parts of the flexure and along elastomer’s centerline, respectively. Theoretical model of the flexure was derived based on its components and a design approach for decoupling strain and temperature cross-effects during sensor usage. In addition, design parameters of the flexure were analyzed on physics-based model optimization using fmincon function, while the static and dynamic properties were analyzed in-silico using finite element method. Further experiments were also carried out to analyze the sensor’s performance, and the data obtained was used for calibration study. The latter was done by training a feed-forward neural network designed for predicting the force vs. wavelength-shift relationship. The experimental results show the designed force sensor design can sense force values in a range of 1N with an average relative error less than 2% of full scale. Ex-vivo tissue palpation experiments were further done on pig liver organs to verify the effectiveness and applicability of the proposed sensor design in minimally invasive surgery.

1 June 2021 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
OOOlatunji Mumini Omisore
Olatunji Mumini Omisore
WDWenke Duan
Wenke Duan
WDWenjing Du
Wenjing Du
YZYuhong Zheng
Yuhong Zheng
TAToluwanimi Akinyemi
Toluwanimi Akinyemi
Lei WangLei Wang
Lei Wang
Background: Cardiovascular diseases resulting from aneurism, thrombosis, and atherosclerosis in the cardiovascular system are major causes of global mortality. Recent treatment methods have been based on catheterization of flexible endovascular tools with imaging guidance. While advances in robotic intravascular catheterization have led to modeling tool navigation approaches with data sensing and feedback, proper adaptation of image-based guidance for robotic navigation requires the development of sensitive segmentation and tracking models without specificity loss. Several methods have been developed to tackle non-uniform illumination, low contrast; however, presence of untargeted body organs commonly found in X-ray frames taken during angiography procedures still presents some major issues to be solved. Methods: In this study, a segmentation method was developed for automatic detection and tracking of guidewire pixels in X-ray angiograms. Image frames were acquired during robotic intravascular catheterization for cardiac interventions. For segmentation, multiscale enhancement filtering was applied on preprocessed X-ray angiograms, while morphological operations and filters were applied to refine the frames for pixel intensity adjustment and vesselness measurement. Minima and maxima extrema of the pixels were obtained to detect guidewire pixels in the X-ray frames. Lastly, morphological operation was applied for guidewire pixel connectivity and tracking in segmented pixels. Method validation was performed on 12 X-ray angiogram sequences which were acquired during in vivo intravascular catheterization trials in rabbits. Results: The study outcomes showed that an overall accuracy of 0.995±0.001 was achieved for segmentation. Tracking performance was characterized with displacement and orientation errors observed as 1.938±2.429 mm and 0.039±0.040°, respectively. Evaluation studies performed against 9 existing methods revealed that this proposed method provides more accurate segmentation with 0.753±0.074 area under curve. Simultaneously, high tracking accuracy of 0.995±0.001 with low displacement and orientation errors of 1.938±2.429 mm and 0.039±0.040°, respectively, were achieved. Also, the method demonstrated higher sensitivity and specificity values compared to the 9 existing methods, with a relatively faster exaction time. Conclusions: The proposed method has the capability to enhance robotic intravascular catheterization during percutaneous coronary interventions (PCIs). Thus, interventionists can be provided with better tool tracking and visualization systems while also reducing their exposure to operational hazards during intravascular catheterization for cardiac interventions.

29 September 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YAYousef Al-handarish
Yousef Al-handarish
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
WDWen ke Duan
Wen ke Duan
JCJing Chen
Jing Chen
LZLuo Zebang
Luo Zebang
Lei WangLei Wang
Lei Wang
Recently, flexible tactile sensors based on three-dimensional (3D) porous conductive composites, endowed with high sensitivity, a wide sensing range, fast response, and the capability to detect low pressures, have aroused considerable attention. These sensors have been employed in different practical domain areas such as artificial skin, healthcare systems, and human–machine interaction. In this study, a facile, cost-efficient method is proposed for fabricating a highly sensitive piezoresistive tactile sensor based on a 3D porous dielectric layer. The proposed sensor is designed with a simple dip-coating homogeneous synergetic conductive network of carbon black (CB) and multi-walled carbon nanotube (MWCNTs) composite on polydimethysiloxane (PDMS) sponge skeletons. The unique combination of a 3D porous structure, with hybrid conductive networks of CB/MWCNTs displayed a superior elasticity, with outstanding electrical characterization under external compression. The piezoresistive tactile sensor exhibited a high sensitivity of (15 kPa−1), with a rapid response time (100 ms), the capability of detecting both large and small compressive strains, as well as excellent mechanical deformability and stability over 1000 cycles. Benefiting from a long-term stability, fast response, and low-detection limit, the piezoresistive sensor was successfully utilized in monitoring human physiological signals, including finger heart rate, pulses, knee bending, respiration, and finger grabbing motions during the process of picking up an object. Furthermore, a comprehensive performance of the sensor was carried out, and the sensor’s design fulfilled vital evaluation metrics, such as low-cost and simplicity in the fabrication process. Thus, 3D porous-based piezoresistive tactile sensors could rapidly promote the development of high-performance flexible sensors, and make them very attractive for an enormous range of potential applications in healthcare devices, wearable electronics, and intelligent robotic systems.

22 October 2018 in IEEE Access
Verified
Journal Article
Open access
WDWenjing Du
Wenjing Du
OOOlatunji Mumini Omisore
Olatunji Mumini Omisore
HLHuihui Li
Huihui Li
KIKamen Ivanov
Kamen Ivanov
SHShipeng Han
Shipeng Han
LWLei Wang
Lei Wang
Chronic low back pain (CLBP) is a common musculoskeletal disorder and a major source of disability in adults. The assessment of lumbar muscle functioning has proven as an appropriate approach for early identification of chronic low back pain when significant pathological signs and symptoms are absent. Thus, earlier therapy or rehabilitation can be administered to prevent further deterioration such as spinal stenosis or disk herniation. In this study, surface electromyography (sEMG) signal analysis was explored for reocgnition of low back pain in subjects with non-specific symptoms. Eighty-eight CLBP subjects and a control group of eighty-three subjects were recruited for sEMG data acquisition. Subjects were asked to perform four specific movements namely, forward bending, backward bending, right lateral flexion, and left lateral flexion. While performing each movement, sEMG signals from three pairs of lumbar muscles were captured, and thirty-one features from both the time and frequency domains were extracted the signal. Finally, the main feature group and four subsets, derived from it, were explored. The suggested method allowed to achieve CLBP recognition accuracy of 98.04% based on subset C for forward bending, followed by 96.15% based on subset E for right lateral flexion, 93.33% based on subset E for left lateral flexion and 91.30% based on subset B for backward bending. A combination of the SVM classifiers and optimal feature selection allowed for improved classification performance. The main aim of this study was to recognize CLBP in subjects with non-specific pathology during four types of movement. The major steps carried out to achieve that are pre-processing, feature selection and classification of the sEMG signals acquired from 171 subjects. Results suggest CLBP recognition based on sEMG as a promising alternative to the conventional methods. Therefore, the present study could inspire the design of appropriate programs that can ensure effective rehabilitation of CLBP patients.